trail charger based charging solutions
... the liftgate batteries is 13.5 volts. The circuit to charge the auxiliary liftgate batteries can be well over 60 feet (on trailer applications). All of this length and connections (including fuses) create voltage drop in the system. Under these circumstances it is impossible to have the correct leve ...
... the liftgate batteries is 13.5 volts. The circuit to charge the auxiliary liftgate batteries can be well over 60 feet (on trailer applications). All of this length and connections (including fuses) create voltage drop in the system. Under these circumstances it is impossible to have the correct leve ...
IEEE Std 112-2004, IEEE Standard Test Procedure for Polyphase
... IEEE Standards Association (IEEE-SA) Standards Board. The IEEE develops its standards through a consensus development process, approved by the American National Standards Institute, which brings together volunteers representing varied viewpoints and interests to achieve the final product. Volunteers ...
... IEEE Standards Association (IEEE-SA) Standards Board. The IEEE develops its standards through a consensus development process, approved by the American National Standards Institute, which brings together volunteers representing varied viewpoints and interests to achieve the final product. Volunteers ...
Evaluation Board User Guide UG-063
... Ten onboard adjustable voltage regulators from Analog Devices, Inc., provide input supply emulation for all different setups supported by the ADM1062 to ADM1169 devices. Each regulator operates independently and output voltages can be easily adjusted by hand using an on-board rotating potentiometer. ...
... Ten onboard adjustable voltage regulators from Analog Devices, Inc., provide input supply emulation for all different setups supported by the ADM1062 to ADM1169 devices. Each regulator operates independently and output voltages can be easily adjusted by hand using an on-board rotating potentiometer. ...
Phase Three Three Stage Smart Charger
... C) Mounting The wiring access port for A.C. input is located on the bottom of the charger. If the factory-installed A.C. cord must be changed for any reason, this should be done before mounting, as access will be difficult afterwards. Also, the drip shield will need to be removed prior to setting th ...
... C) Mounting The wiring access port for A.C. input is located on the bottom of the charger. If the factory-installed A.C. cord must be changed for any reason, this should be done before mounting, as access will be difficult afterwards. Also, the drip shield will need to be removed prior to setting th ...
MiniCloset-5c - Chipkin Automation Systems
... The MC-5c utilizes flash memory which enables reliable data storage and integrity without battery reliance. In addition to metering data, it stores power quality data and a comprehensive list of relevant events. The recorded events include: power consumption, demand resets, power ups and power downs ...
... The MC-5c utilizes flash memory which enables reliable data storage and integrity without battery reliance. In addition to metering data, it stores power quality data and a comprehensive list of relevant events. The recorded events include: power consumption, demand resets, power ups and power downs ...
AutoMax™ Distributed Power System Overview
... components that comprise AC and DC Distributed Power systems and a short introduction to Distributed Power System programming. A glossary of terms used in Distributed Power systems and other AC and DC drive systems can be found in Appendix A. Figures 1.1 to 1.5 illustrate the components of typical D ...
... components that comprise AC and DC Distributed Power systems and a short introduction to Distributed Power System programming. A glossary of terms used in Distributed Power systems and other AC and DC drive systems can be found in Appendix A. Figures 1.1 to 1.5 illustrate the components of typical D ...
TraceNet TCM2 Installation Guide
... Warning: Heat Sink Temperatures May Exceed 60°C Adequate door clearance for service work entry and conduit panel entries should be anticipated when establishing the exact panel location. The panel should be positioned such that the operator can easily access any disconnecting breakers or fuses. When ...
... Warning: Heat Sink Temperatures May Exceed 60°C Adequate door clearance for service work entry and conduit panel entries should be anticipated when establishing the exact panel location. The panel should be positioned such that the operator can easily access any disconnecting breakers or fuses. When ...
MACO Breeze IIc installation manual
... Where external power supplies are required, a CE recognized supply must be used. Test results on CE power supplies have shown that they may emit noise above 30 MHZ. Install a ferrite bead suitable for power cord use at the output terminals of the supply. “Bonding” requires the removal of all non-con ...
... Where external power supplies are required, a CE recognized supply must be used. Test results on CE power supplies have shown that they may emit noise above 30 MHZ. Install a ferrite bead suitable for power cord use at the output terminals of the supply. “Bonding” requires the removal of all non-con ...
DS3904/DS3905 Triple 128-Position Nonvolatile Digital Variable
... from the straight line drawn from the value of the resistance at position 00h to the value of the resistance at position 7Fh. Note 5: Relative linearity is used to determine the change of resistance between two adjacent resistor positions. Note 6: Temperature coefficient specifies the change in resi ...
... from the straight line drawn from the value of the resistance at position 00h to the value of the resistance at position 7Fh. Note 5: Relative linearity is used to determine the change of resistance between two adjacent resistor positions. Note 6: Temperature coefficient specifies the change in resi ...
UL 1699
... reasonable attorney’s fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchaser’s computer system. If a single-user version electronic Standard was purchased, one copy of this Standard may be stored on the hard disk of a single personal ...
... reasonable attorney’s fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchaser’s computer system. If a single-user version electronic Standard was purchased, one copy of this Standard may be stored on the hard disk of a single personal ...
VS-VSKEU300/12PbF
... Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular a ...
... Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular a ...
PSoC® 4 Hardware Design Considerations
... PSoC 4100/4200 supports serial wire debug (SWD) interfaces for device programming and debugging. For programming or debugging, you can connect PSoC 4100/4200 to a CY8CKIT-002 MiniProg3 via a 10-pin or 5-pin connector (pin maps are shown in Figure 6). For a 10-pin connector, Samtec FTSH-105-01-L-DV-K ...
... PSoC 4100/4200 supports serial wire debug (SWD) interfaces for device programming and debugging. For programming or debugging, you can connect PSoC 4100/4200 to a CY8CKIT-002 MiniProg3 via a 10-pin or 5-pin connector (pin maps are shown in Figure 6). For a 10-pin connector, Samtec FTSH-105-01-L-DV-K ...
control of harmonics in electrical power systems
... as long as its level is not substantial. However, with the recent rapid advancement of power electronics technology, so-called nonlinear loads, such as variable frequency drives for motor power/speed control, are increasingly finding their way to shipboard or offshore applications. Harmonics induced ...
... as long as its level is not substantial. However, with the recent rapid advancement of power electronics technology, so-called nonlinear loads, such as variable frequency drives for motor power/speed control, are increasingly finding their way to shipboard or offshore applications. Harmonics induced ...
LTM9012 - Quad 14-Bit, 125Msps ADC with
... Note 7: Integral nonlinearity is defined as the deviation of a code from a best fit straight line to the transfer curve. The deviation is measured from the center of the quantization band. Note 8: Offset error is the offset voltage measured from –0.5 LSB when the output code flickers between 00 0000 ...
... Note 7: Integral nonlinearity is defined as the deviation of a code from a best fit straight line to the transfer curve. The deviation is measured from the center of the quantization band. Note 8: Offset error is the offset voltage measured from –0.5 LSB when the output code flickers between 00 0000 ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.