• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CD4001BC * CD4011BC Quad 2-Input NOR/NAND Buffered B
CD4001BC * CD4011BC Quad 2-Input NOR/NAND Buffered B

... The CD4001BC and CD4011BC quad gates are monolithic complementary MOS (CMOS) integrated circuits constructed with N- and P-channel enhancement mode transistors. They have equal source and sink current capabilities and conform to standard B series output drive. The devices also have buffered outputs ...
TOPIC: 291005 KNOWLEDGE:  K1.01  [2.6/2.6]
TOPIC: 291005 KNOWLEDGE: K1.01 [2.6/2.6]

... A nuclear power plant startup is in progress. The main generator has just been connected to the power grid with the following generator indications: 20 KV 288 amps 10 MW 0 MVAR The operator suspects the main generator is operating under reverse power conditions and attempts to increase generator loa ...
CPM2A OPERATION MANUAL
CPM2A OPERATION MANUAL

... Failure to abide by the following precautions could lead to faulty operation of the PC or the system, or could damage the PC or PC Units. Always heed these precautions. • Fail-safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, or abnormal signals caused ...
Tube Stages for DACs.. - PEARL
Tube Stages for DACs.. - PEARL

SX9300 - Semtech
SX9300 - Semtech

... Upon expiry of the idle timer, a new scan period cycle begins. The scan period determines the minimum reaction time (actual/final reaction time also depends on debounce and filtering settings) and can be programmed from 30ms to 400ms. ...
I-420-EM-B - IOTA Engineering
I-420-EM-B - IOTA Engineering

Resolvers 101
Resolvers 101

... allows it to reject common-mode noise. ...
CD4011BC Quad 2-Input NAND Buffered B Series Gate
CD4011BC Quad 2-Input NAND Buffered B Series Gate

... The CD4001BC and CD4011BC quad gates are monolithic complementary MOS (CMOS) integrated circuits constructed with N- and P-channel enhancement mode transistors. They have equal source and sink current capabilities and conform to standard B series output drive. The devices also have buffered outputs ...
16 Transformer and Transformer-feeder Protection
16 Transformer and Transformer-feeder Protection

... increasing in proportion to the square of the per unit fault current. The typical duration of external short circuits that a transformer can sustain without damage if the current is limited only by the self-reactance is shown in Table 16.1. IEC 60076 provides further guidance on short-circuit withst ...
100% stator ground fault protection
100% stator ground fault protection

... The important role of generators in the power system and the cost of fixing them in case of damage require a protection system against faults, which means, they must be protected against the damage caused by irregular situations in the electrical network or in the generator itself. As stated in Gila ...
Lighting Control and Integrated Home Systems
Lighting Control and Integrated Home Systems

to 1746-NI8 PDF for more information.
to 1746-NI8 PDF for more information.

... configurations, and the placement of components in each location. Decide at this time whether each chassis will have it’s own controller or a networked solution. SLC 500 processors are available with a large range of memory sizes (1 K through ...
(For shunt reactor banks rated to 38kV (200kV BIL and lower), the
(For shunt reactor banks rated to 38kV (200kV BIL and lower), the

... the auto-pneumatic air-blast and hard gas nozzle principle. The switch shall be rated at 135% of the banks nominal current rating and shall have a 40-kA RMS momentary asymmetrical rating. This switch shall be interlocked with the vacuum switches to prevent it from being opened while the filter stage ...
DESIGN OF A PHASE LOCKED LOOP BASED CLOCKING CIRCUIT
DESIGN OF A PHASE LOCKED LOOP BASED CLOCKING CIRCUIT

... mobile devices, the desire for faster, low-power integrated inter-IC communication protocols is at an all-time high and has led the roadmap of the semiconductor industry, making it one of the fastest growing yet fiercely competitive industries. With the growing needs for ultra-low power yet multi-Gb ...
Capacitive Discharge Ignition vs Magnetic
Capacitive Discharge Ignition vs Magnetic

to 1746-HSCE PDF for more information.
to 1746-HSCE PDF for more information.

... configurations, and the placement of components in each location. Decide at this time whether each chassis will have it’s own controller or a networked solution. SLC 500 processors are available with a large range of memory sizes (1 K through ...
LECTURE 6
LECTURE 6

Bourns® FLAT® Technology Gas Discharge Tube (GDT) Surge
Bourns® FLAT® Technology Gas Discharge Tube (GDT) Surge

Resonant Coupling Analysis for a Two-Coil Wireless
Resonant Coupling Analysis for a Two-Coil Wireless

Smart-UPS UPS Operation Manual
Smart-UPS UPS Operation Manual

The Electrical, Thermal and Spatial Integration of a Converter in a
The Electrical, Thermal and Spatial Integration of a Converter in a

... to work in the exciting field of high power density, high temperature power electronics systems and for the financial support to make this Ph.D. thesis possible. I am also deeply grateful to you. My fascination with power electronics was and still is inspired by then my teacher, now my friend, Dr. I ...
AT-AO-6/10 User Manual Expansion Board for the PC AT/EISA
AT-AO-6/10 User Manual Expansion Board for the PC AT/EISA

W9816G6JH 512K × 2 BANKS × 16 BITS SDRAM
W9816G6JH 512K × 2 BANKS × 16 BITS SDRAM

... 512K words  2 banks  16 bits. W9816G6JH delivers a data bandwidth of up to 200M words per second. To fully comply with the personal computer industrial standard, W9816G6JH is sorted into the following speed grades: -5, -6, -6I, -7 and -7I. The -5 grade parts can run up to 200MHz/CL3. The -6 and -6 ...
to 1746-IB16 PDF for more information.
to 1746-IB16 PDF for more information.

... configurations, and the placement of components in each location. Decide at this time whether each chassis will have it’s own controller or a networked solution. SLC 500 processors are available with a large range of memory sizes (1 K through ...
VLSI Design Pass Transistor Logic
VLSI Design Pass Transistor Logic

... Full swing on x (due to Level Restorer) so no static power consumption by inverter ...
< 1 ... 58 59 60 61 62 63 64 65 66 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.