• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Datasheet - StarPower Europe
Datasheet - StarPower Europe

SS8050 NPN Epitaxial Silicon Transistor
SS8050 NPN Epitaxial Silicon Transistor

... 1. Life support devices or systems are devices or 2. A critical component is any component of a life support device or system whose failure to perform can systems which, (a) are intended for surgical implant into be reasonably expected to cause the failure of the life the body, or (b) support or sus ...
HI200-1.pdf
HI200-1.pdf

DMS-20LCD-0/1 Series - Murata Power Solutions
DMS-20LCD-0/1 Series - Murata Power Solutions

... Murata Power Solutions’ new DMS-20LCD-0/1-DCM, self-contained, self-powered, dc voltage monitors set new standards for quality, performance, size and cost. Simply apply power to the two rear terminals and the unit is operational. No additional components are required! The large, 0.37”/9.4mm, LCD dis ...
Kreutter: Circuits 2 Voltage/Current/Resistance Lab Voltage, Current
Kreutter: Circuits 2 Voltage/Current/Resistance Lab Voltage, Current

... Be sure to connect the positive lead from the power supply to the positive terminal of the ammeter. To connect multiple resistors (loads), use alligator clips to fasten them together in series. Your final connection should be to the negative terminal of the power supply. IF YOU SEE OR SMELL SMOKE, ( ...
Trigger Transformers and Chokes
Trigger Transformers and Chokes

... Some types of pulsed lamps generate intense ultraviolet radiation which, if not properly shielded from personnel in the area, will cause burns to any exposed skin and especially to the eyes. Do not expose any skin area or the eyes to the direct or reflected radiation of an operating lamp. If you hav ...
Aug 2002 Lower the Output Voltage Ripple of Positive-to
Aug 2002 Lower the Output Voltage Ripple of Positive-to

... 31µV, thus barely impacting the converter dynamic range. The common mode output voltage of the circuit in Figure 2 is fixed at 0.5V DC, though some loads may require a different level if DC-coupling is to be supported, such as when soft-controlled offset nulling is required. Though not shown here, s ...
Open- circuit test Short
Open- circuit test Short

Experiment No. 6 Output Characteristic of Transistor
Experiment No. 6 Output Characteristic of Transistor

GR 614-C Selective Amplifier, Manual
GR 614-C Selective Amplifier, Manual

... fier is designed fo~ producing with ten fixed tuned circuits; any one of and selecting the first ten harmonics of a which may be placed in circuit by means of distorted 1000- cycle voltage applied to the FREQUENCY switch . A stage of amplifi its input terminals . The instrument is cation follows the ...
DATASHEET: Furman AR-PRO
DATASHEET: Furman AR-PRO

... others with equal ease and without need for readjustment. The AR-PRO uses a design based on a 25-tap toroidal autoformer. The toroidal design assures minimal leakage of stray magnetic fields and a highly efficient, compact package. The AR-PRO’s circuitry monitors the incoming line voltage with each ...
Presentation - Regional Technical Forum
Presentation - Regional Technical Forum

... – Calibrated simulation - Distribution Efficiency Calculator – DE Calculator provides estimate of savings for a substation attributable to each ECM within a multipleECM project – Baseline data may not be available – Reporting period difficult to quantify. Changes to substation operation make it too ...
PDF Version(51KB)
PDF Version(51KB)

... other countries. Compatible with both W-CDMA and LTE network systems, the BA012M1 is a downsized power amplifier that will enable smaller-sized mobile devices. The initial production volume is three million units per month, with shipments starting on November 30. The BA012M1 will be exhibited at 201 ...
MAX1595 Regulated 3.3V/5.0V Step-Up/Step-Down Charge Pump General Description
MAX1595 Regulated 3.3V/5.0V Step-Up/Step-Down Charge Pump General Description

... regulated output. It delivers a maximum 125mA load current. In addition to boost regulating from a lower supply, it is also capable of buck regulating from supplies that exceed the regulated output by a diode drop or more. Designed specifically for compact applications, a complete regulator circuit ...
Overlapping Neutral
Overlapping Neutral

... contacts of the switch could fail. It is a well-known fact that successful operation of any disconnect device, especially under reactive load conditions, is extremely dependent upon rapid "make" and "break" contact action with properly supported arc extinction. Therefore, any transfer switch maker m ...
Alternating Current (AC) vs. Direct Current (DC)
Alternating Current (AC) vs. Direct Current (DC)

... electric charge (current) only flows in one direction. Electric charge in alternating current (AC), on the other hand, changes direction periodically. The voltage in AC circuits also periodically reverses because the current changes direction. Most of the digital electronics that you build will use ...
NTE2107 - NTE Electronics Inc
NTE2107 - NTE Electronics Inc

Low voltage protection Battery overcharge protection
Low voltage protection Battery overcharge protection

XBS024S15R-G
XBS024S15R-G

... protection) are in force for equipment employing products listed in this datasheet. 4. The products in this datasheet are not developed, designed, or approved for use with such equipment whose failure of malfunction can be reasonably expected to directly endanger the life of, or cause significant in ...
Presentación de PowerPoint - cei@upm
Presentación de PowerPoint - cei@upm

... An envelope amplifier for EER and ET techniques is presented here. The prototype has been tested with a Class-E RF power amplifier employing an EER topology, obtaining a drain efficiency of 71% over a 1.5 MHz RF (5 MHz envelope) bandwidth OFDM test signal. This converter is suitable for ET topologie ...
03_EE394J_2_Spring11_HW1_Refresher_Problems
03_EE394J_2_Spring11_HW1_Refresher_Problems

... and the reading is 460Vrms. The electrician then reads the amperes in one of the three a-b-c wires feeding the motor. a. What reading can the electrician expect to see? b. Phase a-b-c wires connecting the motor to a power panel each have 0.1 resistive ohms per phase, and negligible inductance. If th ...
MAX1615/MAX1616 High-Voltage, Low
MAX1615/MAX1616 High-Voltage, Low

... MAX1615/MAX1616 have excellent line-transient response and AC power-supply rejection ratio. They provide a clean, fixed 5V or 3.3V output (MAX1615) or an adjustable 1.24V to 28V output (MAX1616), even when subjected to fast supply-voltage changes that occur during the switchover from battery to AC a ...
7.8.1 The parallel plate capacitor
7.8.1 The parallel plate capacitor

... value for capacitors that are used in everyday circuits. We are more likely to see values in micro farads (μF) and pico farads (pF). ...
ECE2262 Electric Circuits Chapter 6: Capacitance and Inductance
ECE2262 Electric Circuits Chapter 6: Capacitance and Inductance

... we see that the voltage across the inductor is directly proportional to the time rate of change of the current flowing through the inductor. A dc current does not vary with time, so the voltage across the inductor is zero. We can say that an inductor is “a short circuit to dc.” ...
Coupled Inductors
Coupled Inductors

... This voltage is the voltage induced by the coupled current. A transformer can have current entering from both the first and second coils. The voltage across each coil will be dependant on the current through this coil and the induced voltage from the other coil. Suppose the dots are on the same end, ...
< 1 ... 1592 1593 1594 1595 1596 1597 1598 1599 1600 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report