• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Microsoft Word Format - University of Toronto Physics
Microsoft Word Format - University of Toronto Physics

... electrons would drift during one period at the operating frequency. In these devices which are sometimes called overlength devices, the output power depends directly on the material volume. Domains do not form instantaneously but in a time called the dielectric relaxation time which depends on the d ...
Fluke 1735 - Electro Rent
Fluke 1735 - Electro Rent

... consumption testing, and general power quality logging The Fluke 1735 Three-Phase Power Logger is the ideal electrician or technician’s tool for conducting energy studies and basic power quality logging. Set up the 1735 in seconds, with the included flexible current probes and color display. The 173 ...
V/F control
V/F control

EET 251 Unit 2 - Sinclair Community College
EET 251 Unit 2 - Sinclair Community College

HMC855LC5
HMC855LC5

The Modulus Optimum (MO) Method Applied to Voltage
The Modulus Optimum (MO) Method Applied to Voltage

Experimental results
Experimental results

Technical Means of Automation
Technical Means of Automation

... allows continuous measurement in real time voltage and current probes frequency of sampling (e.g. 100Mhz) number of channels (2CH, 4CH) logic signal analyzer (decoding) built-in features ...
Week 1 - Transformer
Week 1 - Transformer

... • changing voltage and current levels in electric power systems. • matching source and load impedances for maximum power transfer in electronic and control circuitry. • electrical isolation (isolating one circuit from another or isolating dc while maintaining ac continuity between two circuits). ...
Electric charges in motion Voltage sources Electrical circuits
Electric charges in motion Voltage sources Electrical circuits

... body is I=V/R. The resistance of your body to the flow of current involves both a contact resistance of the skin and a bulk resistance of the surrounding tissue. The current will increase with increasing voltage or decreasing resistance. So for example, skin that is wet with saline solution with a c ...
TDK-Lambda - SitesPlus
TDK-Lambda - SitesPlus

Practice Test-CP- Electricity 2010
Practice Test-CP- Electricity 2010

... 9) Which of the following wires would have the greatest resistance? a) an aluminum wire 10 cm in length and 3 cm in diameter b) an aluminum wire 5 cm in length and 3 cm in diameter c) an aluminum wire 10 cm in length and 5 cm in diameter d) an aluminum wire 5 cm in length and 5 cm in diameter 10)The ...
Zero-voltage switching for three-level capacitor clamping
Zero-voltage switching for three-level capacitor clamping

... scheme, the main switches work with ZVS through the assistance of a small rating zero-current switching (ZCS) lossless auxiliary circuitry without imposing any voltage/current spikes on the main devices or any extra control complexities. Consequently, a three-level capacitor clamping inverter system ...
to see the PDF file.
to see the PDF file.

... The unit can be placed into a fault condition by pressing the “Test” button on the front of the unit (or by pressing the remote “Test” button - if fitted). The output relay operates accordingly. Press the “Reset” button on the front of the unit (or remotely - if fitted) to reset the unit. The output ...
Fuses Plugs and Switches
Fuses Plugs and Switches

... are based on an electronic circuit and are safer than fuses because they act to cut off the current much more quickly. Direct current (d.c) and Alternating current (a.c) There are two ‘types ‘of electricity depending on how they were produced. Direct current - or d.c. This means current that is alwa ...
NSS20201MR6T1G
NSS20201MR6T1G

... are designed for use in low voltage, high speed switching applications where affordable efficient energy control is important. Typical application are DC−DC converters and power management in portable and battery powered products such as cellular and cordless phones, PDAs, computers, printers, digit ...
LB11870 - ONSemi
LB11870 - ONSemi

... This IC adopts a PLL speed control technique and provides stable motor operation with high precision and low jitter. This PLL circuit compares the phase error at the edges of the CLK signal (falling edges) and FG signal (falling edges on the FGIN+ and FGS signals), and the IC uses the detected error ...
NE5532 - Experimentalists Anonymous
NE5532 - Experimentalists Anonymous

... † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to ...
Floating-Gate Systems
Floating-Gate Systems

OP400
OP400

... In the circuit of Figure 31, which is an extension of the standard three op amp instrumentation amplifier, the output current is proportional to the differential input voltage. Maximum output current is ±5 mA, with voltage compliance equal to ±10 V when using ±15 V supplies. Output impedance of the ...
final cumulative practice test
final cumulative practice test

... more than one path for current to flow. at least two paths for current to flow. only one path for current to flow. more than one path for ground. ...
IS32AP2120 - Integrated Silicon Solution
IS32AP2120 - Integrated Silicon Solution

MAX848/MAX849 1-Cell to 3-Cell, High-Power, Low-Noise, Step-Up DC-DC Converters General Description
MAX848/MAX849 1-Cell to 3-Cell, High-Power, Low-Noise, Step-Up DC-DC Converters General Description

... Note 1: Minimum operating voltage. Because the MAX848/MAX849 are bootstrapped to the output, it will operate down to a 0.7V input. Note 2: In low-power mode (CLK/SEL = GND), the output voltage regulates 1% higher than in low-noise mode (CLK/SEL = OUT or synchronized). Note 3: The part is in start-up ...
Switched-mode power supply
Switched-mode power supply

... efficiency is voltage-out/voltage-in since the volt difference is wasted. In contrast, a switched-mode power supply regulates either output voltage or current by switching ideal storage elements, like inductors and capacitors, into and out of different electrical configurations. Ideal switching elem ...
Methods measure power electronics` efficiency
Methods measure power electronics` efficiency

... connecting the battery to the main power and control board. Meanwhile, capacitor C 2 charges more slowly through 100-kΩ resistor R2, thus generating the control on/off signal with some delay relative to the relay coil’s closing. That scenario occurs after ...
< 1 ... 1373 1374 1375 1376 1377 1378 1379 1380 1381 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report