• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SECTION-4-Chapter 12
SECTION-4-Chapter 12

FAN6747WL Highly Integrated Green-Mode PWM Controller FAN6747WL — Highly Integra
FAN6747WL Highly Integrated Green-Mode PWM Controller FAN6747WL — Highly Integra

... continues to supply VDD until the energy can be delivered from auxiliary winding of the main transformer. VDD must not drop below 9V during startup. This UVLO hysteresis window ensures that the hold-up capacitor is adequate to supply VDD during startup. ...
Doubly Fed Induction Generator for Wind Energy Conversion
Doubly Fed Induction Generator for Wind Energy Conversion

... Fundamental active load current (ild) is obtained using SRF theory [33]. Instantaneous load currents (ilabc) and the value of phase angle from EPLL are used for converting the load currents in to synchronously rotating dq frame (i ld). In synchronously rotating frames, fundamental frequency currents ...
Switch-on voltage in disordered organic field
Switch-on voltage in disordered organic field

... However, for transistors based on the same materials in the crystalline phase, for which the MOSFET theory is valid, the shift of V th with temperature is at most ⯝0.5 V.2,5 This observation raises the question: why, for a disordered system, the shift of V th with temperature is so much larger than ...
Capacitor Discharge Lab
Capacitor Discharge Lab

A Courseware Sample Electric Power / Controls 85822-F0
A Courseware Sample Electric Power / Controls 85822-F0

How Advanced Energy, MDX Products Manage Arcs
How Advanced Energy, MDX Products Manage Arcs

... current to the load (and the arc), the MDX will temporarily draw current (electrons) from the load (Figure 1). This reversal will occur if the process voltage is above a certain minimum, the process current does not exceed a certain maximum, and the impedance of the arc is low enough. For most proce ...
Installation Guide
Installation Guide

... Connection to Modbus Master Set a unique Modbus slave address for each 115S connected to the Modbus Master Example shows address “01” Consult user manual for Modbus addresses ...
Synchronous Generator
Synchronous Generator

... WHAT IS THE ALTERNATOR:• Synchronous generator or basically case machine and ...
Battery Cell Impedance Measurement (EIS)  PSM3750 FRA  + BATT470m
Battery Cell Impedance Measurement (EIS) PSM3750 FRA + BATT470m

JE3416621668
JE3416621668

MAX8513/MAX8514 Wide-Input, High-Frequency, Triple-Output Supplies with Voltage Monitor and Power-On Reset General Description
MAX8513/MAX8514 Wide-Input, High-Frequency, Triple-Output Supplies with Voltage Monitor and Power-On Reset General Description

... xDSL modems, routers, gateways, and set-top boxes. The DC-DC controller switching frequency can be set with an external resistor from 300kHz to 1.4MHz, to allow for the optimization of cost, size, and efficiency. For noisesensitive applications, the DC-DC controller can also be synchronized to an ex ...
Analog Input Module
Analog Input Module

... digital filtering, a technique whereby A/D conversions are averaged before being written to the PLC, enhancing signal stability. The effect of digital filtering on module response to a change in the analog input signal is illustrated in the above chart. The digital filtering level is set by setting ...
PL512/PL506 Modular Power Supply System Technical Manual 6. June 2011
PL512/PL506 Modular Power Supply System Technical Manual 6. June 2011

... double-check correspondence. The mains input connection at the power supply side is described in chapter 2.1 (AC Mains Connection) at page 2. ...
P2 Topic 2 - Downham Market Academy
P2 Topic 2 - Downham Market Academy

... new bulb, but this time with a resistor in the circuit as well. Show students that the bulb survives this time, and ask them to suggest why this is. Main: Students follow the instructions on Worksheet P2.5b. This prompts students to take current and voltage readings at several different power pack v ...
Lecture4 - UCSB ECE
Lecture4 - UCSB ECE

... For short channel (small L) this occurs at Vsat Mobility (m) is a function of doping and temperature ...
INA138-Q1, INA168-Q1
INA138-Q1, INA168-Q1

... Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design impleme ...
Studies on metal–semiconductor contacts with ZrN as metal layer
Studies on metal–semiconductor contacts with ZrN as metal layer

... important role in device application because the capacitance of M-S contacts is voltage dependent. We have used C-V measurements to determine only depletion capacitance and its variation with reverse bias voltage for Schottky barrier structures. The C-V measurements were made by home-built circuit a ...
RS20B 20mm Bi-Stable Shutter System
RS20B 20mm Bi-Stable Shutter System

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... comparator to determine the digital output, hence the input analog signal is converted into digital domain. The input to output conversion of a comparator depends upon the decision making response time of the comparator. Comparator has many application such as in switching power regulator circuit ,B ...
Chapter 8 – Methods of Analysis and Selected Topics (dc)
Chapter 8 – Methods of Analysis and Selected Topics (dc)

... If there is a current source in the network to which the mesh analysis is applied, it can be converted to a voltage source (if a parallel resistor is present) and then the analysis can proceed as before or utilize a supermesh current and proceed as follows  Using the supermesh current, start the sa ...
OPA129 Difet Ultra-Low Bias Current OPERATIONAL AMPLIFIER
OPA129 Difet Ultra-Low Bias Current OPERATIONAL AMPLIFIER

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
LA-101MA
LA-101MA

... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
DAC-HF - DATEL
DAC-HF - DATEL

... 2. Use of a ground plane is particularly important in highspeed D/A converters as it reduces high-frequency noise and aids in decoupling the digital inputs from the analog output. Avoid ground loop problems by connecting all grounds on the board to the ground plane. The remainder of the ground plane ...
PQM (Power  Quality  Meter) Features Introduction HC 6030
PQM (Power Quality Meter) Features Introduction HC 6030

... low control functions to be added for specific applications. This includes basic alarm on over / under current or voltage, ...
< 1 ... 1135 1136 1137 1138 1139 1140 1141 1142 1143 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report