• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Digital Signal Processing
Digital Signal Processing

... • Advantages of Digital over Analogue Signal Processing: A digital programmable system allows flexibility in reconfiguring the DSP operations simply by changing the program. Reconfiguration of an analogue system usually implies a redesign of hardware, testing and verification that it operates prope ...
Lab 11 - Physics Department, Princeton University
Lab 11 - Physics Department, Princeton University

... frequencies are between about 100 and 10,000 Hz. An immediate difficulty is that direct broadcasting of electromagnetic waves of these relatively low frequencies is not very practical, in large part because antennas must be roughly one wavelength long to be efficient. What is the wavelength of a 100 ...
ph104exp11_AM_Radio_04 - Physics Department, Princeton
ph104exp11_AM_Radio_04 - Physics Department, Princeton

... are between about 100 and 10,000 Hz. An immediate difficulty is that direct broadcasting of electromagnetic waves of these relatively low frequencies is not very practical, in large part because antennas must be roughly one wavelength long to be efficient. What is the wavelength of a 100 Hz electrom ...
Exponential Carrier Wave Modulation
Exponential Carrier Wave Modulation

... HL ( f ) K v jf  KH ( f ) ...
Spectrum sensing in cognitive radio networks - GUC
Spectrum sensing in cognitive radio networks - GUC

... •As mentioned earlier, for a good detection algorithm, a high Pd and low Pf should be achieved. The choice of threshold γ is a compromise between Pd and Pf •Usually, the threshold is chosen such that a certain value of false alarm probability Pf is achieved •The threshold selection can be based on e ...
Week 3 - Making the Right Connections
Week 3 - Making the Right Connections

... Balanced vs. Unbalanced  An audio cable is an antenna - it picks up noise along its length  The signal cannot be separated from the noise on an unbalanced signal  A balanced signal can eliminate this noise through “destructive interference”  Unbalanced cables require two conductors,  Balanced ...
DC1164 - High Speed ADC Signal Source Evaluation Kit Quick Start
DC1164 - High Speed ADC Signal Source Evaluation Kit Quick Start

... signal to the demo board. The only connections required in this mode are power, and the output SMA (J2) connected to ADC demo board. The signal amplitude should be close to full scale and the signal amplitude can be controlled by SW1 and the adjacent jumper. The switch has 16 positions corresponding ...
ECE 4117 Experiment 3 Frequency Modulation ECE 4117
ECE 4117 Experiment 3 Frequency Modulation ECE 4117

... The receiving side starts with the channel filter, the Frequency Xlating (translating) FIR filter. The filter does two things, it tunes the signal so that the carrier frequency is translated to 0 Hz and it uses a low pass filter to filter out the unwanted components of the spectrum of signals. Since ...
spring 2016 - Ecs.csus.edu
spring 2016 - Ecs.csus.edu

... pulse train samples the source signal, its frequency should be many times higher than that of the source signal. The zero-order hold block : One important parameter will have to be designed for this block, which is the sampling period of the hold circuit. The sampling period of the circuit should su ...
Introduction to Phasors
Introduction to Phasors

... the Procedure. No extra credit will be given. • The procedures will be modified during the semester to increase the frequency of operation. • 10X probes will be rarely needed when using the oscilloscope. Do not use the 10X probe that came with your oscilloscope except when it is explicitly mentioned ...
ppt
ppt

... AND, for any given medium, the greater the bandwidth transmitted, the greater the cost HOWEVER, limiting the bandwidth creates distortions ...
ppt
ppt

... AND, for any given medium, the greater the bandwidth transmitted, the greater the cost HOWEVER, limiting the bandwidth creates distortions ...
Chemical Analysis - Wake Forest University
Chemical Analysis - Wake Forest University

... Accuracy, Precision, Signal-to-Noise Ratio Sensitivity, Limit of Detection Linearity, Linear Dynamic Range ...
Chemical Analysis - Wake Forest University
Chemical Analysis - Wake Forest University

... Accuracy, Precision, Signal-to-Noise Ratio Sensitivity, Limit of Detection Linearity, Linear Dynamic Range ...
PDF of the lab
PDF of the lab

... where the message information is encoded in the amplitude of a series of signal pulses. The output is a series of pulses, the amplitude of which vary in proportion to the modulating signal. The samples are taken at regular interval of time. ...
Ultrasonic Ranging Module HC
Ultrasonic Ranging Module HC

... Ultrasonic ranging module HC - SR04 provides 2cm - 400cm non-contact measurement function, the ranging accuracy can reach to 3mm. The modules includes ultrasonic transmitters, receiver and control circuit. The basic principle of work: (1) Using IO trigger for at least 10us high level signal, (2) The ...
HC-SR04 - Micropik
HC-SR04 - Micropik

... Ultrasonic ranging module HC - SR04 provides 2cm - 400cm non-contact measurement function, the ranging accuracy can reach to 3mm. The modules includes ultrasonic transmitters, receiver and control circuit. The basic principle of work: (1) Using IO trigger for at least 10us high level signal, (2) The ...
INTRODUCTION TO THE POWER LAB AND LAB TUTOR
INTRODUCTION TO THE POWER LAB AND LAB TUTOR

... activities of humans and animals for which the signal or data analysis and manipulation become very much easy and less time consuming. ...
Paper E1 - Digital Circuits
Paper E1 - Digital Circuits

... resonance curve ...
< 1 2 3

Signal Corps Laboratories

Signal Corps Laboratories (SCL) was formed on June 30, 1930, as part of the U.S. Army Signal Corps at Fort Monmouth, New Jersey. Through the years, the SCL had a number of changes in name, but remained the operation providing research and development services for the Signal Corps.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report