GS-50HQP,VQP-1APD
... 3. Optional steel/cupronickel refrigerant-to-water heat exchanger shall be used for open loop applications, or where water quality cannot be maintained as specified by manufacturer. F. Refrigerant Components: 1. Refrigeration circuit components shall include liquid line service valve, suction line s ...
... 3. Optional steel/cupronickel refrigerant-to-water heat exchanger shall be used for open loop applications, or where water quality cannot be maintained as specified by manufacturer. F. Refrigerant Components: 1. Refrigeration circuit components shall include liquid line service valve, suction line s ...
50PEC, Guide Specifications, 6,220 to 20,760 Btuh Cooling
... shall be factory fabricated from heavy gage galvanized steel, finished with powder coat paint. Cabinet dimensions are in accordance with drawings and are manufactured for left or right water discharge piping. Cabinet shall be single-piece construction. Removal of the cabinet shall give complete side ...
... shall be factory fabricated from heavy gage galvanized steel, finished with powder coat paint. Cabinet dimensions are in accordance with drawings and are manufactured for left or right water discharge piping. Cabinet shall be single-piece construction. Removal of the cabinet shall give complete side ...
Temperature Detectors: Choosing The Correct Device To Fit
... RTDs (Figure 1) consist of a wire coil or deposited film of pure metal for which the change in resistance is a known function of temperature. The common RTD types by metal, and their characteristic resistance and base temperature are: copper (10.0Ω @ 25° C), platinum (100Ω @ 0° C), and nickel (120Ω ...
... RTDs (Figure 1) consist of a wire coil or deposited film of pure metal for which the change in resistance is a known function of temperature. The common RTD types by metal, and their characteristic resistance and base temperature are: copper (10.0Ω @ 25° C), platinum (100Ω @ 0° C), and nickel (120Ω ...
Lecture 4 Refrigerator
... Avoid the use of electrical extension cords The electrical outlet must not be more than 2 m from the unit Install the unit on a levelled surface Leave free space around unit to avoid over heating Do not install under direct sun light ...
... Avoid the use of electrical extension cords The electrical outlet must not be more than 2 m from the unit Install the unit on a levelled surface Leave free space around unit to avoid over heating Do not install under direct sun light ...
Temperature Measurement using sensors and
... In lab a RTD, thermistor, and thermocouple were placed in a beaker of 750mL of water and readings were taken from 19°C to 80°C. The next two slides show the results. ...
... In lab a RTD, thermistor, and thermocouple were placed in a beaker of 750mL of water and readings were taken from 19°C to 80°C. The next two slides show the results. ...
DG5.0 DX with ECWS Setup Instructions rev
... When the unit is configured for ECWS, proportional cooling is mutually exclusive of compressor cooling. When the proportional cooling input is enabled, the proportional cool output is selected for ECWS (as opposed to PC), the chilled water sensor indicates that the chilled water temperature is below ...
... When the unit is configured for ECWS, proportional cooling is mutually exclusive of compressor cooling. When the proportional cooling input is enabled, the proportional cool output is selected for ECWS (as opposed to PC), the chilled water sensor indicates that the chilled water temperature is below ...
Thermostat
A thermostat is a component of a HVAC control system which senses the temperature of a system so that the system's temperature is maintained near a desired setpoint. The thermostat does this by switching heating or cooling devices on or off, or regulating the flow of a heat transfer fluid as needed, to maintain the correct temperature.A thermostat may be a control unit for a heating or cooling system or a component part of or air conditioner. Thermostats can be constructed in many ways and may use a variety of sensors to measure the temperature. The output of the sensor then controls the heating or cooling apparatus. A thermostat may switch on and off at temperatures either side of the setpoint. This prevents equipment damage from frequent switching. Thermostats are also used in many household appliances. A thermostat is an instance of a ""bang-bang controller"" as the heating or cooling system output is not proportional to the difference between actual temperature and the set temperature; the equipment runs at full capacity until the set temperature is reached, then shuts off. Increasing the difference between the thermostat setting and the desired temperature therefore does not shorten the time to achieve the desired temperature.The term is derived from the Greek words θερμός thermos, ""comfortable"" and στατός statos, ""climate controlled"".