Action PAK ®
... the total number of pulses counted in a given time period represents the time integral of the DC input. If, for example, the input represents a flow in gallons per hour, then the time integral of this flow signal (total count) will represent total gallons. The AP7500’s 6V square wave output can be u ...
... the total number of pulses counted in a given time period represents the time integral of the DC input. If, for example, the input represents a flow in gallons per hour, then the time integral of this flow signal (total count) will represent total gallons. The AP7500’s 6V square wave output can be u ...
MAX3480EA/MAX3480EB ±15kV ESD-Protected, Isolated, 3.3V RS-485/RS-422 Data Interfaces General Description
... Transceivers, optocouplers, and a transformer are all included in one low-cost, 28-pin PDIP package. A single +3.3V supply on the logic side powers both sides of the interface. The MAX3480EB features reduced-slew-rate drivers that minimize EMI and reduce reflections caused by improperly terminated c ...
... Transceivers, optocouplers, and a transformer are all included in one low-cost, 28-pin PDIP package. A single +3.3V supply on the logic side powers both sides of the interface. The MAX3480EB features reduced-slew-rate drivers that minimize EMI and reduce reflections caused by improperly terminated c ...
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP
... Susquehanna-Roseland corridor for interconnections to the existing offsite power transmission grid as shown in Figure 8.2-1. The two circuits are supported on separate structures, which are located to minimize the likelihood of simultaneous failure. Transmission tower separation, line installation, ...
... Susquehanna-Roseland corridor for interconnections to the existing offsite power transmission grid as shown in Figure 8.2-1. The two circuits are supported on separate structures, which are located to minimize the likelihood of simultaneous failure. Transmission tower separation, line installation, ...
Understanding Transducer Specifications
... is said to echo—just as your voice will echo off a canyon wall. When the reflected sound wave returns the transducer acts as a microphone. It receives the sound wave during the time between each transmit pulse and converts it back into electrical energy. A transducer will spend about 1% of its time ...
... is said to echo—just as your voice will echo off a canyon wall. When the reflected sound wave returns the transducer acts as a microphone. It receives the sound wave during the time between each transmit pulse and converts it back into electrical energy. A transducer will spend about 1% of its time ...
Debouncing Switches
... -a 10uS bounce (short) is (1x10-5/62.5x10-9) 160 instructions long! -a 100uS bounce could be sampled as a valid true or false 100’s of times -results are incorrect behavior as seen by user Characteristics of switch bounce: -nearly all switches do it -the duration of bouncing and the period of each b ...
... -a 10uS bounce (short) is (1x10-5/62.5x10-9) 160 instructions long! -a 100uS bounce could be sampled as a valid true or false 100’s of times -results are incorrect behavior as seen by user Characteristics of switch bounce: -nearly all switches do it -the duration of bouncing and the period of each b ...
ILB SERIES - Iota Engineering
... IOTA Engineering is dedicated to providing products that meet the standards our customers demand as well as the superior service they deserve. All IOTA products receive 100% quality inspection before shipment to ensure proper and satisfactory operation. IOTA warranties all emergency drivers in the ...
... IOTA Engineering is dedicated to providing products that meet the standards our customers demand as well as the superior service they deserve. All IOTA products receive 100% quality inspection before shipment to ensure proper and satisfactory operation. IOTA warranties all emergency drivers in the ...
AESO System Operating Limits Methodology for the Planning Horizon (R1 FAC-010-AB-2.1)
... (i) a common mode outage of two (2) generating units connected to the same switchyard not otherwise addressed by reliability standard FAC-010-AB; or (ii) the loss of multiple bus sections as a result of failure or delayed clearing of a bus tie or bus sectionalizing breaker to clear a permanent phase ...
... (i) a common mode outage of two (2) generating units connected to the same switchyard not otherwise addressed by reliability standard FAC-010-AB; or (ii) the loss of multiple bus sections as a result of failure or delayed clearing of a bus tie or bus sectionalizing breaker to clear a permanent phase ...
Proper Termination of Digital Incremental Encoder
... The 422 data transmission standard (ANSI TIA/EIA-422, formally) is a balanced scheme for transmitting digital data over long distances with very good noise immunity. In this scheme, the driver D takes a single signal and generates two complementary or differential signals. These are then sent out ov ...
... The 422 data transmission standard (ANSI TIA/EIA-422, formally) is a balanced scheme for transmitting digital data over long distances with very good noise immunity. In this scheme, the driver D takes a single signal and generates two complementary or differential signals. These are then sent out ov ...
Driving High Power, High Brightness LEDs
... The connection scheme will influence the number of drivers channel needed. Most LED driver typically has a single channel. However, there are some multi channel LED drivers available. Each channel can drive only a single series connected LEDs or a single branch of the parallel connected LED in commo ...
... The connection scheme will influence the number of drivers channel needed. Most LED driver typically has a single channel. However, there are some multi channel LED drivers available. Each channel can drive only a single series connected LEDs or a single branch of the parallel connected LED in commo ...
Application Note
... If only part of the machine is fitted with AC drives, the situation is slightly more complex. With a good understanding of the application, one can determine the motoring and regenerative requirements for each section driven by the AC drive. Under worst case conditions, if the net flow of power is s ...
... If only part of the machine is fitted with AC drives, the situation is slightly more complex. With a good understanding of the application, one can determine the motoring and regenerative requirements for each section driven by the AC drive. Under worst case conditions, if the net flow of power is s ...
TIMERS
... in its present state. This intermediate input region is a deadspace where there is no response, a property called hysteresis, it is like backlash in a mechanical linkage. This type of circuit is called a Schmitt trigger. • If high sensitivity is required the hysteresis is a problem, but in many circ ...
... in its present state. This intermediate input region is a deadspace where there is no response, a property called hysteresis, it is like backlash in a mechanical linkage. This type of circuit is called a Schmitt trigger. • If high sensitivity is required the hysteresis is a problem, but in many circ ...
EEE-PP-010 - 6572
... The first five-phase induction motor drive system was proposed in the late 1970s for adjustable speed drive applications. Since then, a considerable research effort has been in place to develop commercially feasible multiphase drive Systems .Multiphase (more than three phase) systems are the focus o ...
... The first five-phase induction motor drive system was proposed in the late 1970s for adjustable speed drive applications. Since then, a considerable research effort has been in place to develop commercially feasible multiphase drive Systems .Multiphase (more than three phase) systems are the focus o ...
Lecture 17
... – This can cause very complicated behavior A simpler model: Stuck-At – Assume all failures cause nodes to be “stuck-at” 0 or 1, i.e. shorted to GND or VDD – Not quite true, but works well in practice ...
... – This can cause very complicated behavior A simpler model: Stuck-At – Assume all failures cause nodes to be “stuck-at” 0 or 1, i.e. shorted to GND or VDD – Not quite true, but works well in practice ...
Precision Low Dropout Linear Controllers (Rev. A)
... Driver sink to source voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 V TRC pin voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
... Driver sink to source voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 V TRC pin voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
ERP020-030-040 data sheet revF 26OCT2016
... or guarantee regarding the suitability of its products for any particular purpose, nor does ERP assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental da ...
... or guarantee regarding the suitability of its products for any particular purpose, nor does ERP assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental da ...
Cinénova Grande - earthquakedenmark.dk
... enjoyment. The Cinénova Grande is conceived to reproduce"true to life" music as it was originally recorded, without tempering, coloration or compression. Like the finer things in life, the Cinénova Grande was conceived with love for details, hunger for power, and gratifying grace; consequently ranki ...
... enjoyment. The Cinénova Grande is conceived to reproduce"true to life" music as it was originally recorded, without tempering, coloration or compression. Like the finer things in life, the Cinénova Grande was conceived with love for details, hunger for power, and gratifying grace; consequently ranki ...
Diodes, Transistors and Mixers
... Microwave FETS with GaAs– greater e- mobility– f>4GHZ Excellent freq. response & noise performance ...
... Microwave FETS with GaAs– greater e- mobility– f>4GHZ Excellent freq. response & noise performance ...
Microwave Engineering - Universiti Sains Malaysia
... Let’s ZT(I,s)= Zin(I,s) +ZL(s) Where I current and s=jw is a complex frequency. Then for a small change in current dI and in frequency ds, the Taylor’s series for ZT(I,s) is ...
... Let’s ZT(I,s)= Zin(I,s) +ZL(s) Where I current and s=jw is a complex frequency. Then for a small change in current dI and in frequency ds, the Taylor’s series for ZT(I,s) is ...
Auto-Zero Amplifiers
... A wide variety of electronic applications, especially those involving very small input signals, require signal paths with very low offset voltage and offset voltage drift over time and temperature. When standard linear components are used, the only way to achieve this low offset and drift is to use ...
... A wide variety of electronic applications, especially those involving very small input signals, require signal paths with very low offset voltage and offset voltage drift over time and temperature. When standard linear components are used, the only way to achieve this low offset and drift is to use ...