ZPAK II Debug Interface Module
... 3. Connect the TIM to the ZDI port on the target development board. Align pin 1 of the TIM to pin 1 of the development board’s ZDI socket. 5. If using an Ethernet hub, connect an Ethernet patch cable from a free port on the Ethernet hub to the Ethernet port on the ZPAK II module. Connect the PC’s Et ...
... 3. Connect the TIM to the ZDI port on the target development board. Align pin 1 of the TIM to pin 1 of the development board’s ZDI socket. 5. If using an Ethernet hub, connect an Ethernet patch cable from a free port on the Ethernet hub to the Ethernet port on the ZPAK II module. Connect the PC’s Et ...
Switched Broadcast 2003
... Client connects to Conserver host Clients are connected to logging streams ...
... Client connects to Conserver host Clients are connected to logging streams ...
ruggedcom rx1500/1501
... ROX II allows individual ports to be ‘hard’ configured for speed, duplex, auto-negotiation, flow control and more. This allows proper connection with devices that do not negotiate or have unusual settings. Detailed status of ports with alarm and SNMP trap on link problems aid greatly in system troub ...
... ROX II allows individual ports to be ‘hard’ configured for speed, duplex, auto-negotiation, flow control and more. This allows proper connection with devices that do not negotiate or have unusual settings. Detailed status of ports with alarm and SNMP trap on link problems aid greatly in system troub ...
CAN FD - Bosch Semiconductors and Sensors
... In automotive electronics, engine control units, sensors, anti-skid-systems, etc. are connected using CAN with bitrates up to 1 Mbit/s. At the same time it is cost effective to build into vehicle body electronics, e.g. lamp clusters, electric windows etc. to replace the wiring harness otherwise requ ...
... In automotive electronics, engine control units, sensors, anti-skid-systems, etc. are connected using CAN with bitrates up to 1 Mbit/s. At the same time it is cost effective to build into vehicle body electronics, e.g. lamp clusters, electric windows etc. to replace the wiring harness otherwise requ ...
Freescale presentation template
... A CAN network with multiple nodes will most likely carry a lot of messages. For any given message, each CAN node has to determine if this message is intended for them: ...
... A CAN network with multiple nodes will most likely carry a lot of messages. For any given message, each CAN node has to determine if this message is intended for them: ...
User Manual
... The 605M-R1 Industrial Router provides data routing functionality between multiple connected TCP/IP devices. Since TCP/IP connections are point-to-point only, a number of remote TCP/IP clients may each connect to the 605M-R1 simultaneously, which can then route data between those client devices as n ...
... The 605M-R1 Industrial Router provides data routing functionality between multiple connected TCP/IP devices. Since TCP/IP connections are point-to-point only, a number of remote TCP/IP clients may each connect to the 605M-R1 simultaneously, which can then route data between those client devices as n ...
Plant Floor Network Levels
... Serial port for configuration and PLC programming Supports external power for transceiver ...
... Serial port for configuration and PLC programming Supports external power for transceiver ...
RuggedBackbone™ RX1500/1501
... ROX™II allows individual ports to be ‘hard’ configured for speed, duplex, auto-negotiation, flow control and more. This allows proper connection with devices that do not negotiate or have unusual settings. Detailed status of ports with alarm and SNMP trap on link problems aid greatly in system troub ...
... ROX™II allows individual ports to be ‘hard’ configured for speed, duplex, auto-negotiation, flow control and more. This allows proper connection with devices that do not negotiate or have unusual settings. Detailed status of ports with alarm and SNMP trap on link problems aid greatly in system troub ...
Training 204
... delivers traffic only to those who want it routers communicate with each other and users to gather the information once information is shared, the traffic is sent where it needs to go ...
... delivers traffic only to those who want it routers communicate with each other and users to gather the information once information is shared, the traffic is sent where it needs to go ...
ppt - DTN Things on a DSG web server
... Generally not (very) strictly scheduled Less predictable data flows Broader applicability ...
... Generally not (very) strictly scheduled Less predictable data flows Broader applicability ...
basic stamp serial
... address can’t include any bytes that equal another node’s address. For example, if a master node sends a node address of 1 followed by a data byte of 7, when node 7 sees the data byte, it will think that master is addressing it. A way around this is to send all data with a Dec, Hex, or Bin modifier ...
... address can’t include any bytes that equal another node’s address. For example, if a master node sends a node address of 1 followed by a data byte of 7, when node 7 sees the data byte, it will think that master is addressing it. A way around this is to send all data with a Dec, Hex, or Bin modifier ...
tele - De Montfort University
... Page Select (usually 0) 8-Bit PDU Format 8-Bit PDU Specific 8-Bit user defined unused ...
... Page Select (usually 0) 8-Bit PDU Format 8-Bit PDU Specific 8-Bit user defined unused ...
a closer look at ber, part 1
... Reed-Solomon block, spread out with each bit error in a single Reed-Solomon symbol. This is more than t = 3, so the decoder can't correct the errors. It usually detects this condition and outputs the data unchanged. (The decoder should do it this way, depending on implementation.) What does this mea ...
... Reed-Solomon block, spread out with each bit error in a single Reed-Solomon symbol. This is more than t = 3, so the decoder can't correct the errors. It usually detects this condition and outputs the data unchanged. (The decoder should do it this way, depending on implementation.) What does this mea ...
Chapter 1. Introduction to Data Communications
... Parity Checking • One of the oldest and simplest • A single bit added to each character – Even parity: number of 1’s remains even – Odd parity: number of 1’s remains odd ...
... Parity Checking • One of the oldest and simplest • A single bit added to each character – Even parity: number of 1’s remains even – Odd parity: number of 1’s remains odd ...
Chapter 4: Data Link Layer - Joseph H. Schuessler, PhD
... Parity Checking • One of the oldest and simplest • A single bit added to each character – Even parity: number of 1’s remains even – Odd parity: number of 1’s remains odd ...
... Parity Checking • One of the oldest and simplest • A single bit added to each character – Even parity: number of 1’s remains even – Odd parity: number of 1’s remains odd ...
ch2
... be used over short distances. • Technology- limited to in-building environments • Radio bands at 5.2 GHz and 17 GHz are allocated to HIPPERLAN in Europe and 2.4 GHz for use with the IEEE 802.11 standard, which supports data rates up to 54 Mbps. • Bluetooth – radio, operates in the 2.45 GHz band – Us ...
... be used over short distances. • Technology- limited to in-building environments • Radio bands at 5.2 GHz and 17 GHz are allocated to HIPPERLAN in Europe and 2.4 GHz for use with the IEEE 802.11 standard, which supports data rates up to 54 Mbps. • Bluetooth – radio, operates in the 2.45 GHz band – Us ...
Chapter 4. Data Link Layer
... Parity Checking • One of the oldest and simplest • A single bit added to each character – Even parity: number of 1’s remains even – Odd parity: number of 1’s remains odd ...
... Parity Checking • One of the oldest and simplest • A single bit added to each character – Even parity: number of 1’s remains even – Odd parity: number of 1’s remains odd ...
ch04
... Parity Checking • One of the oldest and simplest • A single bit added to each character – Even parity: number of 1’s remains even – Odd parity: number of 1’s remains odd ...
... Parity Checking • One of the oldest and simplest • A single bit added to each character – Even parity: number of 1’s remains even – Odd parity: number of 1’s remains odd ...
lecture20
... “best effort” service, UDP segments may be: lost delivered out-of-order to app connectionless: no handshaking between UDP sender, receiver each UDP segment handled independently of others ...
... “best effort” service, UDP segments may be: lost delivered out-of-order to app connectionless: no handshaking between UDP sender, receiver each UDP segment handled independently of others ...
Connecting a Single Computer to the XAP Net LAN Port
... with a COM port and network interface card, and G-Ware 5.0 installed. Before you can connect to the LAN port, you will need to connect to your XAP Net serially and assign a static IP address. You will then need to configure the IP settings for your computer’s network interface card. Note: You may al ...
... with a COM port and network interface card, and G-Ware 5.0 installed. Before you can connect to the LAN port, you will need to connect to your XAP Net serially and assign a static IP address. You will then need to configure the IP settings for your computer’s network interface card. Note: You may al ...
Embedded Computer
... 7", 16:9 Digital touch wide screen, 800×480 physical resolution, with rich colors; ...
... 7", 16:9 Digital touch wide screen, 800×480 physical resolution, with rich colors; ...
PAGE 818. The following new Section is added after Section... 684 NETWORK DEVICES.
... compression technology in accordance with the International Organization for Standardization (ISO) and International Electrotechnical Commission (IEC) requirements detailed in the ISO/IEC 14496-10:2009 standard. Ensure that the DVE and DVD are capable of unicast and multicast operation. Ensure that ...
... compression technology in accordance with the International Organization for Standardization (ISO) and International Electrotechnical Commission (IEC) requirements detailed in the ISO/IEC 14496-10:2009 standard. Ensure that the DVE and DVD are capable of unicast and multicast operation. Ensure that ...
24 FE + 4 GE Combo SFP L2 SNMP Switch
... centralized control of the switch and avoids unauthorized users from altering the configuration. Comprehensive QoS LevelOne FGL-2870 offers 4 egress queues per port, which enables differentiated management of up to 4 traffic types. Traffic is prioritized according to 802.1p and DSCP, giving optimal ...
... centralized control of the switch and avoids unauthorized users from altering the configuration. Comprehensive QoS LevelOne FGL-2870 offers 4 egress queues per port, which enables differentiated management of up to 4 traffic types. Traffic is prioritized according to 802.1p and DSCP, giving optimal ...
Controller Area Network (CAN)
... For real-time control over a network it may be advisable to implement a communication protocol that guarantees that messages meet timing deadlines regardless of the load on the bus. One such protocol that retains the CAN data link layer protocol is “time-triggered CAN,” or TTCAN (ISO 11898-4) [7]. A ...
... For real-time control over a network it may be advisable to implement a communication protocol that guarantees that messages meet timing deadlines regardless of the load on the bus. One such protocol that retains the CAN data link layer protocol is “time-triggered CAN,” or TTCAN (ISO 11898-4) [7]. A ...
Serial port
In computing, a serial port is a serial communication physical interface through which information transfers in or out one bit at a time (in contrast to a parallel port). Throughout most of the history of personal computers, data was transferred through serial ports to devices such as modems, terminals and various peripherals.While such interfaces as Ethernet, FireWire, and USB all send data as a serial stream, the term ""serial port"" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device.Modern computers without serial ports may require serial-to-USB converters to allow compatibility with RS 232 serial devices. Serial ports are still used in applications such as industrial automation systems, scientific instruments, point of sale systems and some industrial and consumer products. Server computers may use a serial port as a control console for diagnostics. Network equipment (such as routers and switches) often use serial console for configuration. Serial ports are still used in these areas as they are simple, cheap and their console functions are highly standardized and widespread. A serial port requires very little supporting software from the host system.