TGR-Elec. Valves - AVS Danmark A/S
... down from a preselected number and gives a pneumatic signal output when zero is reached. The output can then be used to actuate or initiate machine functions. Counters are preset by depressing the reset button, and at the same time entering the desired preset figure by depressing the preset keys. It ...
... down from a preselected number and gives a pneumatic signal output when zero is reached. The output can then be used to actuate or initiate machine functions. Counters are preset by depressing the reset button, and at the same time entering the desired preset figure by depressing the preset keys. It ...
RF3158 Features
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
AD5641: 英文产品数据手册下载
... power-on reset circuit, which ensures that the DAC output powers up to 0 V and remains there until a valid write to the device takes place. The AD5641 contains a power-down feature that reduces current consumption typically to 0.2 μA at 3 V, and provides software-selectable output loads while in pow ...
... power-on reset circuit, which ensures that the DAC output powers up to 0 V and remains there until a valid write to the device takes place. The AD5641 contains a power-down feature that reduces current consumption typically to 0.2 μA at 3 V, and provides software-selectable output loads while in pow ...
DC/DC converter
... order to ensure protection from short circuit and overload of the IGBT. This involves monitoring the collector voltage and turning off the device if this voltage rises above a certain limit. The best method for detecting desaturation is the use of an external fast or super-fast high voltage clamp di ...
... order to ensure protection from short circuit and overload of the IGBT. This involves monitoring the collector voltage and turning off the device if this voltage rises above a certain limit. The best method for detecting desaturation is the use of an external fast or super-fast high voltage clamp di ...
RF6590 POWER MANAGEMENT IC Features
... • SPI logic voltage should not exceed 1.8 volts (Output 2 supply) during operation. • Do not exceed listed currents in CLK mode, otherwise the Output voltage will fall out of regulation. • Register 0 must be restored by the controller, whenever the mode enters TRX mode. All registers should be consi ...
... • SPI logic voltage should not exceed 1.8 volts (Output 2 supply) during operation. • Do not exceed listed currents in CLK mode, otherwise the Output voltage will fall out of regulation. • Register 0 must be restored by the controller, whenever the mode enters TRX mode. All registers should be consi ...
TPS54120EVM, Low Noise 1A Power Supply Evaluation Module
... The power input of the IC (PVIN) is rated for 1.6V to 17V while the control input (VIN) is rated for 4.5 to 17V. The TPS54120 provides both inputs but this EVM is designed and tested using the PVIN connected to VIN with a minimum input voltage of 7V. Rated input voltage and output current range for ...
... The power input of the IC (PVIN) is rated for 1.6V to 17V while the control input (VIN) is rated for 4.5 to 17V. The TPS54120 provides both inputs but this EVM is designed and tested using the PVIN connected to VIN with a minimum input voltage of 7V. Rated input voltage and output current range for ...
S260-60-3
... In the event that the ac power has not returned within the times listed above, the control will disconnect the battery from the circuit. NNote: The control continuously monitors the battery voltage. To prevent battery damage, the control shuts down automatically upon detection of low battery voltage ...
... In the event that the ac power has not returned within the times listed above, the control will disconnect the battery from the circuit. NNote: The control continuously monitors the battery voltage. To prevent battery damage, the control shuts down automatically upon detection of low battery voltage ...
LT5521 - Very High Linearity Active Mixer.
... Note 1: Absolute Maximum Ratings are those values beyond which the life of a device may be impaired. Note 2: Specifications over the –40°C to 85°C temperature range are assured by design, characterization and correlation with statistical process controls. Note 3: Interval from the rising edge of the ...
... Note 1: Absolute Maximum Ratings are those values beyond which the life of a device may be impaired. Note 2: Specifications over the –40°C to 85°C temperature range are assured by design, characterization and correlation with statistical process controls. Note 3: Interval from the rising edge of the ...
NCP1612 - Enhanced, High‐Efficiency Power Factor Controller
... 2. This device(s) contains ESD protection and exceeds the following tests: Human Body Model 2000 V per JEDEC Standard JESD22−A114E Machine Model Method 200 V per JEDEC Standard JESD22−A115−A Charged Device Model Method 200 V per JEDEC Standard JESD22−C101E 3. This device contains latch-up protection ...
... 2. This device(s) contains ESD protection and exceeds the following tests: Human Body Model 2000 V per JEDEC Standard JESD22−A114E Machine Model Method 200 V per JEDEC Standard JESD22−A115−A Charged Device Model Method 200 V per JEDEC Standard JESD22−C101E 3. This device contains latch-up protection ...
Voltage Output DACs
... 16-Bit Octal DAC with 10ppm/°C (Max) Internal Reference The 16-bit LTC®2656 combines eight voltage output DACs with guaranteed ±4LSB INL and ±1LSB DNL, and achieves ultralow AC and DC crosstalk to ensure rock-solid control in precision multichannel open or closed loop systems. The complete family of ...
... 16-Bit Octal DAC with 10ppm/°C (Max) Internal Reference The 16-bit LTC®2656 combines eight voltage output DACs with guaranteed ±4LSB INL and ±1LSB DNL, and achieves ultralow AC and DC crosstalk to ensure rock-solid control in precision multichannel open or closed loop systems. The complete family of ...
REG710-25 数据资料 dataSheet 下载
... In normal operation, the charging of the pump and output capacitors usually leads to relatively high peak input currents which can be much higher than that of the average load current. The regulator incorporates circuitry to limit the input peak current, lowering the total EMI production of the devi ...
... In normal operation, the charging of the pump and output capacitors usually leads to relatively high peak input currents which can be much higher than that of the average load current. The regulator incorporates circuitry to limit the input peak current, lowering the total EMI production of the devi ...
Doherty Amplifier with DSP Control to Improve Performance in CDMA Operation WE3A-1
... into the DSP controller. This phase predistortion data is also shown in Fig. 8. It should be noted that the conventional approach of gain predistortion at baseband gives very little benefit in improving the ACPR in the system described in Fig. 4, since it is ultimately the gate bias of the auxiliary ...
... into the DSP controller. This phase predistortion data is also shown in Fig. 8. It should be noted that the conventional approach of gain predistortion at baseband gives very little benefit in improving the ACPR in the system described in Fig. 4, since it is ultimately the gate bias of the auxiliary ...
Old Company Name in Catalogs and Other Documents
... 4. Thermal derating factor is –7.6 mV/°C when operating ambient temperature is higher than 50°C. 5. Thermal derating factor is –5.5 mV/°C when operating ambient temperature is higher than 25°C. 6. Pay careful attention to the total power dissipation not to exceed the absolute maximum ratings, Note 4 ...
... 4. Thermal derating factor is –7.6 mV/°C when operating ambient temperature is higher than 50°C. 5. Thermal derating factor is –5.5 mV/°C when operating ambient temperature is higher than 25°C. 6. Pay careful attention to the total power dissipation not to exceed the absolute maximum ratings, Note 4 ...
MAX9152 800Mbps LVDS/LVPECL-to-LVDS 2 x 2 Crosspoint Switch General Description
... intended for point-to-point communication over a controlled impedance medium as defined by the ANSI TIA/EIA-644 and IEEE 1596.3 standards. LVDS uses a lower voltage swing than other common communication standards, achieving higher data rates with reduced power consumption while reducing EMI emission ...
... intended for point-to-point communication over a controlled impedance medium as defined by the ANSI TIA/EIA-644 and IEEE 1596.3 standards. LVDS uses a lower voltage swing than other common communication standards, achieving higher data rates with reduced power consumption while reducing EMI emission ...
No Slide Title
... proportional valve needs to be regulated and not just simply switched on or off as is the case with a conventional valve. ...
... proportional valve needs to be regulated and not just simply switched on or off as is the case with a conventional valve. ...
MAX8614A/MAX8614B Dual-Output (+ and -) DC-DC Converters for CCD General Description
... the amplified current-sense signal and a slope-compensation ramp. At the beginning of each clock cycle, the internal power switch turns on until the PWM comparator trips. During this time the current in the inductor ramps up, storing energy in the inductor’s magnetic field. When the power switch tur ...
... the amplified current-sense signal and a slope-compensation ramp. At the beginning of each clock cycle, the internal power switch turns on until the PWM comparator trips. During this time the current in the inductor ramps up, storing energy in the inductor’s magnetic field. When the power switch tur ...
MAX6695/MAX6696 Dual Remote/Local Temperature Sensors with SMBus Serial Interface General Description
... each diode’s forward voltages and compute the temperature based on these voltages. If a remote channel is not used, connect DXP_ to DXN. Do not leave DXP_ and DXN unconnected. When a conversion is initiated, all channels are converted whether they are used or not. The DXN input is biased at one VBE ...
... each diode’s forward voltages and compute the temperature based on these voltages. If a remote channel is not used, connect DXP_ to DXN. Do not leave DXP_ and DXN unconnected. When a conversion is initiated, all channels are converted whether they are used or not. The DXN input is biased at one VBE ...
TPS6217x 3-V to 17-V, 0.5-A Step-Down
... This control loop takes information about output voltage changes and feeds it directly to a fast comparator stage. It sets the switching frequency, which is constant for steady state operating conditions, and provides immediate response to dynamic load changes. To get accurate DC load regulation, a ...
... This control loop takes information about output voltage changes and feeds it directly to a fast comparator stage. It sets the switching frequency, which is constant for steady state operating conditions, and provides immediate response to dynamic load changes. To get accurate DC load regulation, a ...
ABB industrial drives ACS880, multidrive modules Catalog
... quick connectors as standard. The modules can also be quickly pulled out from a cabinet without any need for disconnecting the motor cables. This is done simply by disconnecting a couple of bolts. The R8i inverter module comes equipped with a removable fan pedestal, which makes motor cabling easy. T ...
... quick connectors as standard. The modules can also be quickly pulled out from a cabinet without any need for disconnecting the motor cables. This is done simply by disconnecting a couple of bolts. The R8i inverter module comes equipped with a removable fan pedestal, which makes motor cabling easy. T ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.