SN74CBTLV1G125-Q1 数据资料 dataSheet 下载
... such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI product ...
... such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI product ...
Basics of Motor Control Centers
... here rotates 3600 times per minute (3600 RPM), the generator produces 60 cycles of voltage per second, or 60 hertz (Hz). If the generator had four poles, it would generate the needed 60 Hz with a rotational speed of 1800 RPM. Three-Phase Voltage ...
... here rotates 3600 times per minute (3600 RPM), the generator produces 60 cycles of voltage per second, or 60 hertz (Hz). If the generator had four poles, it would generate the needed 60 Hz with a rotational speed of 1800 RPM. Three-Phase Voltage ...
TX25/50 FM Broadcast Transmitter
... Please note that the power supply units in this equipment is of the switched mode variety and have lethal voltages present internally. The switched mode supplies are universal input fully approved type. They are non serviceable modules and should be fully replaced should they fail. FUSES Only use fu ...
... Please note that the power supply units in this equipment is of the switched mode variety and have lethal voltages present internally. The switched mode supplies are universal input fully approved type. They are non serviceable modules and should be fully replaced should they fail. FUSES Only use fu ...
SECTION 265113 * INTERIOR LIGHTING FIXTURES, LAMPS, AND
... Manufacturer Qualification: Manufacturer of DALI-compliant network lighting ballasts with minimum 10 years record of satisfactory manufacturing and support of lighting and ...
... Manufacturer Qualification: Manufacturer of DALI-compliant network lighting ballasts with minimum 10 years record of satisfactory manufacturing and support of lighting and ...
AP3154A
... For an SDI command to be successfully received by the AP3154A, all SDI timing specifications should be satisfied. When no command is being sent the SDI pin should be held high. If the SDI pin goes low and stays low for a time length of between TSLO(min) and TSLO(max) and then goes high and stays hig ...
... For an SDI command to be successfully received by the AP3154A, all SDI timing specifications should be satisfied. When no command is being sent the SDI pin should be held high. If the SDI pin goes low and stays low for a time length of between TSLO(min) and TSLO(max) and then goes high and stays hig ...
SECTION 26 51 13 INTERIOR LIGHTING FIXTURES, LAMPS, AND
... Manufacturer Qualification: Manufacturer of DALI-compliant network lighting ballasts with minimum 10 years record of satisfactory manufacturing and support of lighting and ...
... Manufacturer Qualification: Manufacturer of DALI-compliant network lighting ballasts with minimum 10 years record of satisfactory manufacturing and support of lighting and ...
Installation and Operating Instructions GeoSource Ultra
... result in higher floor temperatures needed to heat the building, which could exceed the level of human comfort. Night setback controls are not recommended on radiant floor systems due to the slow response time of the slab, and radiant floor systems are not usually recommended for cooling, since poor ...
... result in higher floor temperatures needed to heat the building, which could exceed the level of human comfort. Night setback controls are not recommended on radiant floor systems due to the slow response time of the slab, and radiant floor systems are not usually recommended for cooling, since poor ...
Low noise cryogenic electronics : preamplifier - CEA-Irfu
... previously proposed preamplifier configurations with feedback on the bolometer [4] and of the classical unlooped voltage amplifier readout [7]. Preamplifiers have been developed or are under test for each of these configurations. First we will use a simple adiabatic model of bolometer with standard ...
... previously proposed preamplifier configurations with feedback on the bolometer [4] and of the classical unlooped voltage amplifier readout [7]. Preamplifiers have been developed or are under test for each of these configurations. First we will use a simple adiabatic model of bolometer with standard ...
MAX17502 60V, 1A, Ultra-Small, High-Efficiency, Synchronous Step-Down DC-DC Converter General Description
... The device uses a peak-current-mode control scheme. An internal transconductance error amplifier generates an integrated error voltage. The error voltage sets the duty cycle using a PWM comparator, a high-side current-sense amplifier, and a slope-compensation generator. At each rising edge of the cl ...
... The device uses a peak-current-mode control scheme. An internal transconductance error amplifier generates an integrated error voltage. The error voltage sets the duty cycle using a PWM comparator, a high-side current-sense amplifier, and a slope-compensation generator. At each rising edge of the cl ...
Installation Manual Engineered Pump Systems (EPS)
... The nature of sewage pumps is to pass solids. Each sewage pump has a solids-handling specification that it is designed to pass. On the other hand a grinder pump will grind any solids into a slurry, and then pump them. Occasionally, a pump being used to pump sewage will become jammed on a large solid ...
... The nature of sewage pumps is to pass solids. Each sewage pump has a solids-handling specification that it is designed to pass. On the other hand a grinder pump will grind any solids into a slurry, and then pump them. Occasionally, a pump being used to pump sewage will become jammed on a large solid ...
400- to 690-V AC Input 50-W Flyback Isolated
... voltage rating of the drive. Opto-couplers are used for isolated feedback and to regulate the output voltage. In case of failure of components used in the feedback path, the output may reach a dangerously high level, which would damage all the electronic components. Use of controllers like the UCC38 ...
... voltage rating of the drive. Opto-couplers are used for isolated feedback and to regulate the output voltage. In case of failure of components used in the feedback path, the output may reach a dangerously high level, which would damage all the electronic components. Use of controllers like the UCC38 ...
v series ii powered subwoofers
... product before shipping to KRK Systems. A return authorization number from KRK Systems is also required before shipping a product to KRK Systems for repair. After obtaining a return authorization number from KRK Systems, all KRK Systems products in need of repair can be returned to the dealer where ...
... product before shipping to KRK Systems. A return authorization number from KRK Systems is also required before shipping a product to KRK Systems for repair. After obtaining a return authorization number from KRK Systems, all KRK Systems products in need of repair can be returned to the dealer where ...
Application Note 74 LM139/LM239/LM339 A Quad
... meet the needs for a medium speed, TTL compatible comparator for industrial applications. Since no antisaturation clamps are used on the output such as a Baker clamp or other active circuitry, the output leakage current in the OFF state is typically 0.5 nA. This makes the device ideal for system app ...
... meet the needs for a medium speed, TTL compatible comparator for industrial applications. Since no antisaturation clamps are used on the output such as a Baker clamp or other active circuitry, the output leakage current in the OFF state is typically 0.5 nA. This makes the device ideal for system app ...
HMC349MS8G - SeekDataSheet
... The HMC349MS8G is a high isolation nonreflective DC to 4 GHz GaAs MESFET SPDT switch in a low cost 8 lead MSOP8G surface mount package with an exposed ground paddle. The switch is ideal for cellular/PCS/3G basestation applications yielding 50 to 60 dB isolation, low 0.8 dB insertion loss and +52 dBm ...
... The HMC349MS8G is a high isolation nonreflective DC to 4 GHz GaAs MESFET SPDT switch in a low cost 8 lead MSOP8G surface mount package with an exposed ground paddle. The switch is ideal for cellular/PCS/3G basestation applications yielding 50 to 60 dB isolation, low 0.8 dB insertion loss and +52 dBm ...
ADL5355 数据手册DataSheet 下载
... to allow for single-ended operation. The ADL5355 incorporates an RF balun, allowing for optimal performance over a 1200 MHz to 2500 MHz RF input frequency range using low-side LO injection for RF frequencies from 1700 MHz to 2500 MHz and high-side LO injection for RF frequencies from 1200 MHz to 170 ...
... to allow for single-ended operation. The ADL5355 incorporates an RF balun, allowing for optimal performance over a 1200 MHz to 2500 MHz RF input frequency range using low-side LO injection for RF frequencies from 1700 MHz to 2500 MHz and high-side LO injection for RF frequencies from 1200 MHz to 170 ...
Transient Response versus Ripple
... other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. ...
... other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. ...
Written Specification (pdf document)
... internally supplied to the inputs). The 24 VDC power supply is provided with an autoresettable fuse. Should an inappropriate electrical connection be made the design will protect the board and switches until the fault is removed. Any switch input shall be software linked to any number of relays fo ...
... internally supplied to the inputs). The 24 VDC power supply is provided with an autoresettable fuse. Should an inappropriate electrical connection be made the design will protect the board and switches until the fault is removed. Any switch input shall be software linked to any number of relays fo ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.