• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
D Speed Control Motors
D Speed Control Motors

MAX1817 Compact, High-Efficiency, Dual-Output Step-Up DC-DC Converter General Description
MAX1817 Compact, High-Efficiency, Dual-Output Step-Up DC-DC Converter General Description

... switches only as often as is required to supply sufficient power to the load. This allows the converter to operate at lower frequencies at light loads, improving efficiency. The control scheme maintains regulation when the error amplifier senses the output voltage is below the feedback threshold, tu ...
Checklist to EN 60204-1
Checklist to EN 60204-1

CL1 203C-2 - QRS Renewables
CL1 203C-2 - QRS Renewables

... PL Solar charge controller 60/30A; ROHS 1 Energy System Controllers The PL series controllers offer complete controller over the charge cycle and gives information about current and past performance.  12V, 24V, 32V, 36V and 48V in one controller  Built-in 30 days data logger  Multifunctional LCD ...
AN3095
AN3095

LM2676 - Texas Instruments
LM2676 - Texas Instruments

... socket, or on a PCB with minimum copper area. Junction to ambient thermal resistance (no external heat sink) for the 7-lead TO-220 package mounted vertically, with 0.5 in leads soldered to a PCB containing approximately 4 square inches of (1 oz) copper area surrounding the leads. Junction to ambient ...
210254: MICROPROCESSOR INTERFACING LABORATORY
210254: MICROPROCESSOR INTERFACING LABORATORY

Document
Document

AD9753 数据手册DataSheet 下载
AD9753 数据手册DataSheet 下载

... The AD9753 has been optimized for ultrahigh speed applications up to 300 MSPS where data rates exceed those possible on a single data interface port DAC. The digital interface consists of two buffered latches as well as control logic. These latches can be time multiplexed to the high speed DAC in se ...
Archived: 5B Series User Manual
Archived: 5B Series User Manual

... Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices.for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise ...
Potentiometer
Potentiometer

arduinob
arduinob

ISL4489E, ISL4491E
ISL4489E, ISL4491E

4-channel BTL driver for CD players and CD-ROM
4-channel BTL driver for CD players and CD-ROM

... (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of with would directly endanger ...
Motor Drive and Control Solutions (Rev. I)
Motor Drive and Control Solutions (Rev. I)

... • Supports both single and double precision ...
Specifying a Solenoid
Specifying a Solenoid

SN54AHCT123A, SN74AHCT123A (Rev. G)
SN54AHCT123A, SN74AHCT123A (Rev. G)

... To prevent malfunctions due to noise, connect a high-frequency capacitor between VCC and GND, and keep the wiring between the external components and Cext and Rext/Cext terminals as short as possible. ...
Rotor side control of grid-connected wound rotor induction machine
Rotor side control of grid-connected wound rotor induction machine

... The speed of a cage rotor induction machine is primarily determined by the supply frequency. The short-circuited rotor offers very low resistance and the nominal slip is within 5%. In the case of a wound rotor induction machine it is possible to introduce additional resistance in the rotor circuit a ...
Application Note Evaluation Board 3kW dual phase LLC
Application Note Evaluation Board 3kW dual phase LLC

... The combined trends of a continuous reduction of volume and size of the power converters and an increase in required output power represent a serious challenge in modern switch mode power supply (SMPS) designs. When addressing the high power density requirement, even in a SMPS with high peak efficie ...
PAM8012AZN - Diodes Incorporated
PAM8012AZN - Diodes Incorporated

... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Installation, Maintenance And Troubleshooting
Installation, Maintenance And Troubleshooting

HD1200/1 Manual
HD1200/1 Manual

... drops, these wires should  be upgraded to 4 AWG pure copper wire (or larger) when installing amplifier systems with main fuse ratings above 60A. Turn-On Wire The HD1200/1 uses a conventional +12V remote turn-on wire, typically controlled by the source unit’s remote turn-on output. The amplifier will ...
Old Company Name in Catalogs and Other Documents
Old Company Name in Catalogs and Other Documents

... 4. Thermal derating factor is –7.6 mW/°C when operating ambient temperature is higher than 50°C. 5. Thermal derating factor is –5.5 mW/°C when operating ambient temperature is higher than 25°C. 6. Pay careful attention to the total power dissipation not to exceed the absolute maximum ratings, Note 4 ...
TPS548B22 1.5-V to 18-V VIN, 4.5-V to 22-V VDD, 25
TPS548B22 1.5-V to 18-V VIN, 4.5-V to 22-V VDD, 25

1 Static Characteristics I
1 Static Characteristics I

< 1 ... 77 78 79 80 81 82 83 84 85 ... 528 >

Control system



A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report