Oscillators - UniMAP Portal
... loop, the voltagedivider ratio must be adjusted such that a positive feedback loop gain of 1 is produced. This requires a closedloop gain of 3. The ratio of R1 and R2 can be set to achieve this. ...
... loop, the voltagedivider ratio must be adjusted such that a positive feedback loop gain of 1 is produced. This requires a closedloop gain of 3. The ratio of R1 and R2 can be set to achieve this. ...
CAT853 - 3-Pin Microprocessor Power Supply
... The CAT853, CAT863, CAT859, and CAT869 protect mPs against brownout failure. Short duration transients of 4 ms or less and 100 mV amplitude typically do not cause a false RESET. Figure 7 shows the maximum pulse duration of negative−going VCC transients that do not cause a reset condition. As the amp ...
... The CAT853, CAT863, CAT859, and CAT869 protect mPs against brownout failure. Short duration transients of 4 ms or less and 100 mV amplitude typically do not cause a false RESET. Figure 7 shows the maximum pulse duration of negative−going VCC transients that do not cause a reset condition. As the amp ...
Changes to the FADC buffer circuits and ASIC mux out buffer/ADC
... R68 and R76 (assuming minimal output impedance and high input impedance of AD4932/8). For the original 3K3 design the current per channel is (1.6/6.6) mA = 0.24mA so total is 3.9mA, well within 15mA drive capability of AD8031. However, the 3K3 values need to be reduced for amplifier stability and co ...
... R68 and R76 (assuming minimal output impedance and high input impedance of AD4932/8). For the original 3K3 design the current per channel is (1.6/6.6) mA = 0.24mA so total is 3.9mA, well within 15mA drive capability of AD8031. However, the 3K3 values need to be reduced for amplifier stability and co ...
Design of Ultra-Low-Power Analog-to-Digital Converters Dai Zhang
... low resolution, the power consumption is bounded by digital switching power; 2) at medium-to-high resolution, the power consumption is bounded by thermal noise if digital assisted techniques are used to alleviate mismatch issues; otherwise it is bounded by capacitor mismatch. Conversion of the low f ...
... low resolution, the power consumption is bounded by digital switching power; 2) at medium-to-high resolution, the power consumption is bounded by thermal noise if digital assisted techniques are used to alleviate mismatch issues; otherwise it is bounded by capacitor mismatch. Conversion of the low f ...
How to Prevent Temperature Measurement Errors
... Nearly two-thirds of all temperature measurement in the US makes use of the thermocouple in some form. Likewise, most industrial applications remotely sense temperature using thermocouples, and optionally transmit the thermocouple signal some distance using industrial transmitters for the purpose of ...
... Nearly two-thirds of all temperature measurement in the US makes use of the thermocouple in some form. Likewise, most industrial applications remotely sense temperature using thermocouples, and optionally transmit the thermocouple signal some distance using industrial transmitters for the purpose of ...
micromaster 430
... The device contains components which can be destroyed by electrostatic discharge. These components can be easily destroyed if not carefully handled. Before opening the cabinet/enclosure in which the device is located, you must electrically discharge your body and apply the appropriate ESDS protectiv ...
... The device contains components which can be destroyed by electrostatic discharge. These components can be easily destroyed if not carefully handled. Before opening the cabinet/enclosure in which the device is located, you must electrically discharge your body and apply the appropriate ESDS protectiv ...
Personal Daq/3000 Series
... counter inputs can be synchronously scanned [along with analog inputs] but do not affect the overall A/D rate because they use no time slot in the scanning sequencer. For example, one analog input can be scanned at the full 1-MHz A/D rate along with digital and counter input channels. The 1-MHz A/D ...
... counter inputs can be synchronously scanned [along with analog inputs] but do not affect the overall A/D rate because they use no time slot in the scanning sequencer. For example, one analog input can be scanned at the full 1-MHz A/D rate along with digital and counter input channels. The 1-MHz A/D ...
Activity 3A
... The electrical relay offers a simple ON/OFF switching action in response to a control signal. Figure 3.2 illustrates the principle. When a current flows through the coil of wire a magnetic field is produced. This pulls a movable arm that forces the contact to open or close. This might then be used t ...
... The electrical relay offers a simple ON/OFF switching action in response to a control signal. Figure 3.2 illustrates the principle. When a current flows through the coil of wire a magnetic field is produced. This pulls a movable arm that forces the contact to open or close. This might then be used t ...
Rotary Encoder Interface Spartan
... In the design provided, you should find that each ‘click’ of the shaft moves the illuminated LED one position only. Note that it is one position every time and not suddenly several positions even if you turn it really slowly or click it one position in an ‘instant’ (try it and see). If this control ...
... In the design provided, you should find that each ‘click’ of the shaft moves the illuminated LED one position only. Note that it is one position every time and not suddenly several positions even if you turn it really slowly or click it one position in an ‘instant’ (try it and see). If this control ...
to - Vacuum Electric Switch Co.
... The geometric configuration of this switch may result in the parasitic capacitance in parallel with each vacuum interrupter being unequal. This is most likely to occur when this switch is used on poles where objects in close proximity will most likely cause a larger portion of the recovery voltage t ...
... The geometric configuration of this switch may result in the parasitic capacitance in parallel with each vacuum interrupter being unequal. This is most likely to occur when this switch is used on poles where objects in close proximity will most likely cause a larger portion of the recovery voltage t ...
network lighting control system
... 10. Data Line Communications: The controller shall be equipped with serial communications through RJ45 connectors for communicating on CAT-5 cable with other panels and LightSync devices. It shall also be equipped with a separate local port for communicating with LightSync devices. The communication ...
... 10. Data Line Communications: The controller shall be equipped with serial communications through RJ45 connectors for communicating on CAT-5 cable with other panels and LightSync devices. It shall also be equipped with a separate local port for communicating with LightSync devices. The communication ...
MAX98356 PDM Input Class D Audio Power Amplifier General Description Features
... (PDM) input Class D power amplifier that provides Class AB audio performance with Class D efficiency. This IC offers five selectable gain settings (3dB, 6dB, 9dB, 12dB, and 15dB) set by a single gain-select input (GAIN). The MAX98356 takes a stereo pulse density modulated (SPDM) input signal directl ...
... (PDM) input Class D power amplifier that provides Class AB audio performance with Class D efficiency. This IC offers five selectable gain settings (3dB, 6dB, 9dB, 12dB, and 15dB) set by a single gain-select input (GAIN). The MAX98356 takes a stereo pulse density modulated (SPDM) input signal directl ...
ENG- FM FM1 FM2 Keeping Ovens Operating Manual
... Place the electrode trays in the oven chamber. Switch on the oven main power switch for few minutes to eliminate any possible humidity residual on the new heating element. Switch it off and await about 15 minutes before switching it on again and making the oven on operation. This allows the heating ...
... Place the electrode trays in the oven chamber. Switch on the oven main power switch for few minutes to eliminate any possible humidity residual on the new heating element. Switch it off and await about 15 minutes before switching it on again and making the oven on operation. This allows the heating ...
Dual Precision Retriggerable/Resettable Monostable
... (while inputs B and Reset are held to VDD) a valid trigger is recognized, which turns on comparator C1 and N−channel transistor N1 ➀. At the same time the output latch is set. With transistor N1 on, the capacitor CX rapidly discharges toward VSS until Vref1 is reached. At this point the output of co ...
... (while inputs B and Reset are held to VDD) a valid trigger is recognized, which turns on comparator C1 and N−channel transistor N1 ➀. At the same time the output latch is set. With transistor N1 on, the capacitor CX rapidly discharges toward VSS until Vref1 is reached. At this point the output of co ...
PQMII Power Quality Meter Instruction Manual
... GE Digital Energy PQMII Power Quality Meter instruction manual for revision 2.2x. PQMII Power Quality Meter, is a registered trademark of GE Digital Energy Inc. The contents of this manual are the property of GE Digital Energy Inc. This documentation is furnished on license and may not be reproduced ...
... GE Digital Energy PQMII Power Quality Meter instruction manual for revision 2.2x. PQMII Power Quality Meter, is a registered trademark of GE Digital Energy Inc. The contents of this manual are the property of GE Digital Energy Inc. This documentation is furnished on license and may not be reproduced ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.