
a 8-Bit Octal, 4-Quadrant Multiplying, CMOS TrimDAC AD8842
... Internally the AD8842 contains eight voltage output digital-toanalog converters, each with separate voltage inputs. A new current conveyor amplifier design performs the four-quadrant multiplying function with a single amplifier at the output of the current steering digital-to-analog converter. This ...
... Internally the AD8842 contains eight voltage output digital-toanalog converters, each with separate voltage inputs. A new current conveyor amplifier design performs the four-quadrant multiplying function with a single amplifier at the output of the current steering digital-to-analog converter. This ...
An RF Analog Design from Concept to First Prototype
... • Input power between 6 & 10 dBm for full output power to interface with most transverters and ATV modulators • Linear output power about 20 watts – so about 36dB gain • Input attenuator for gain adjustment up to about 10dB loss. • Low power use when not in transmit – less than 5 mA with LEDs • LED ...
... • Input power between 6 & 10 dBm for full output power to interface with most transverters and ATV modulators • Linear output power about 20 watts – so about 36dB gain • Input attenuator for gain adjustment up to about 10dB loss. • Low power use when not in transmit – less than 5 mA with LEDs • LED ...
10.7-MHz Fully Balanced, High-Q, Wide-Dynamic-Range Current-Tunable Gm-C Bandpass Filter Worawat Sa-Ngiamvibool
... current-tunable Gm-C bandpass filter is introduced using two fully balanced devices, i.e. an adder and a low-Q-based bandpass filter. The high-Q factor is equal to a common-emitter current gain β. For the first time, the high-Q factor is typically constant as it is no longer a function of variables ...
... current-tunable Gm-C bandpass filter is introduced using two fully balanced devices, i.e. an adder and a low-Q-based bandpass filter. The high-Q factor is equal to a common-emitter current gain β. For the first time, the high-Q factor is typically constant as it is no longer a function of variables ...
t06096.pdf
... type of telemanipulation as the surgeon is bodily separated from operational theater. So, telerobotics is a normal means to expand capabilities in minimally invasive surgery. In telerobotics surgery, surgical tool can be replaced with automatic tool which are directly controlled by surgeon from remo ...
... type of telemanipulation as the surgeon is bodily separated from operational theater. So, telerobotics is a normal means to expand capabilities in minimally invasive surgery. In telerobotics surgery, surgical tool can be replaced with automatic tool which are directly controlled by surgeon from remo ...
Control relays
... The label gives the wiring scheme for the device together with other information (type, rating, voltage, etc). Mounting the relay in any other position has virtually no effect on its operating characteristics. ...
... The label gives the wiring scheme for the device together with other information (type, rating, voltage, etc). Mounting the relay in any other position has virtually no effect on its operating characteristics. ...
Sensorless Control for a Switched Reluctance Wind Generator
... means higher cost and additional complexity but also increases the vulnerability of electronic systems. In some applications, environmental conditions do not allow the use of encoders. To avoid the use of a position encoder, it is necessary to use control algorithms that are able to estimate the pos ...
... means higher cost and additional complexity but also increases the vulnerability of electronic systems. In some applications, environmental conditions do not allow the use of encoders. To avoid the use of a position encoder, it is necessary to use control algorithms that are able to estimate the pos ...
1.2 Ideal Op-Amp
... Ideally, output of an op-amp is 0 Volt if the input is 0 Volt. Realistically, a small dc voltage will appear at the output when no input voltage is applied. Thus, differential dc voltage is required between the inputs to force the output to zero volts. This is called the Input Offset Voltage, Vos. R ...
... Ideally, output of an op-amp is 0 Volt if the input is 0 Volt. Realistically, a small dc voltage will appear at the output when no input voltage is applied. Thus, differential dc voltage is required between the inputs to force the output to zero volts. This is called the Input Offset Voltage, Vos. R ...
High-Voltage, High-Current OPERATIONAL AMPLIFIER DESCRIPTION FEATURES
... The OPA547 is a low-cost, high-voltage/high-current operational amplifier ideal for driving a wide variety of loads. A laser-trimmed monolithic integrated circuit provides excellent low-level signal accuracy and high output voltage and current. The OPA547 operates from either single or dual supplies ...
... The OPA547 is a low-cost, high-voltage/high-current operational amplifier ideal for driving a wide variety of loads. A laser-trimmed monolithic integrated circuit provides excellent low-level signal accuracy and high output voltage and current. The OPA547 operates from either single or dual supplies ...
Operation manual for BLHeli Atmel Rev13.x
... Typically a medium setting will work fine, but if the motor stutters it can be beneficial to change timing. Some motors with high inductance can have a very long commutation demagnetization time. This results in motor stop or stutter upon quick throttle increase, particularly when running at a low r ...
... Typically a medium setting will work fine, but if the motor stutters it can be beneficial to change timing. Some motors with high inductance can have a very long commutation demagnetization time. This results in motor stop or stutter upon quick throttle increase, particularly when running at a low r ...
0319 - Three Axis Low-g Micromachined Accelerometer
... 2. These limits define the range of operation for which the part will meet specification. 3. Within the supply range of 2.2 and 3.6 V, the device operates as a fully calibrated linear accelerometer. Beyond these supply limits the device may operate as a linear device but is not guaranteed to be in c ...
... 2. These limits define the range of operation for which the part will meet specification. 3. Within the supply range of 2.2 and 3.6 V, the device operates as a fully calibrated linear accelerometer. Beyond these supply limits the device may operate as a linear device but is not guaranteed to be in c ...
HMC233G8
... The HMC233G8 is a broadband high isolation nonreflective GaAs MESFET SPDT switch in a hermetic surface mount package. Covering DC to 6 GHz, the switch features >44 dB isolation up to 2 GHz and >31 dB isolation up to 6 GHz. The switch operates ...
... The HMC233G8 is a broadband high isolation nonreflective GaAs MESFET SPDT switch in a hermetic surface mount package. Covering DC to 6 GHz, the switch features >44 dB isolation up to 2 GHz and >31 dB isolation up to 6 GHz. The switch operates ...
BSDEs and risk-sensitive control, zero-sum and nonzero
... In this paper, mainly, we deal with the risk-sensitive control and zero-sum game (which we describe below) problems of functional di-usions. The main tool is the notion of BSDEs which has been already used in risk neutral optimal stochastic control and game problems (see e.g. Hamad2ene and Lepeltier ...
... In this paper, mainly, we deal with the risk-sensitive control and zero-sum game (which we describe below) problems of functional di-usions. The main tool is the notion of BSDEs which has been already used in risk neutral optimal stochastic control and game problems (see e.g. Hamad2ene and Lepeltier ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.