• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Speed Control of Induction Machines
Speed Control of Induction Machines

ELECTriCAL MAChinEs
ELECTriCAL MAChinEs

GIGAVAC HXNC241 Normally Closed EPIC DC Contactor
GIGAVAC HXNC241 Normally Closed EPIC DC Contactor

... 4 Contactor has two coils. Both are used for pick-up, and then in approximately 75 milliseconds, one coil is electronically removed from the coil drive circuit. The remaining coil supplies low continuous hold power sufficient for the contactor to meet all of its specified performance specifications. ...
C400 Snap-action switches
C400 Snap-action switches

Thunder Tarp Operation Instructions Rev G
Thunder Tarp Operation Instructions Rev G

Transformer Protection
Transformer Protection

Technology Training that works
Technology Training that works

... • Squared-Exponential Loads - With machines of this type, torque varies directly as the speed, and power as the square of speed. Such relationships are frequently found in positive-displacement pumps and mixer applications • Cubed-Exponential Loads - It is a characteristic of these machines that tor ...
Electric Circuits – Resistors in Parallel
Electric Circuits – Resistors in Parallel

MicroControlWhitePaper
MicroControlWhitePaper

Load Models, including Induction Machines
Load Models, including Induction Machines

LEESON Basic Training
LEESON Basic Training

... DC motors have extremely high torque capabilities and can be used in conjunction with relatively simple solid state control devices to give programmed acceleration and deceleration over a wide range of selected speeds. Because the speed of a DC motor is not dependent on the number of poles, there is ...
magnetic field - the SASPhysics.com
magnetic field - the SASPhysics.com

erii18_servos - Cornerstone Robotics
erii18_servos - Cornerstone Robotics

... o A servo motor is a motor that can be controlled to turn to a specified position. Typically, a servo is used in hobby applications such as controlling steering for an RC (radio-controlled) car or the rudder for an RC airplane. o Most servos (servo motors) have a position range of 180 degrees (check ...
Single and Three Phase Transformer Testing Using Static Motor
Single and Three Phase Transformer Testing Using Static Motor

C-Bypass - Siemens
C-Bypass - Siemens

2. electrostatic type voltmeter
2. electrostatic type voltmeter

... connected in series with the load, therefore the load current will flow through these coils.  Now the reason is very obvious of using two fixed coils instead of one, so that it can be constructed to carry considerable amount of electric current.  These coils are called the current coils of electro ...
Fuses - Time Delay
Fuses - Time Delay

... the Cooper Bussmann dual-element, time-delay fuses can be sized closer to provide both high performance short circuit protection and reliable overload protection in circuits subject to temporary overloads and surge currents. For AC motor loads, a single-element fuse may need to be sized at 300% of a ...
AG-AMIII-01.423-05.4 Electric Motors
AG-AMIII-01.423-05.4 Electric Motors

... Revised June 2011 ...
EE 1281721
EE 1281721

... motor (PMSM) and Brushless DC Motor (BLDC) drives are being used widely. One of the most popular approaches is a generalized harmonic injection [1]. In high speed applications like traction, the primary concern of drives is to obtain a low frequency and ripple free torque and even flux control. For ...
Vertical Induction Motors - High Thrust Hollow
Vertical Induction Motors - High Thrust Hollow

... Allow enough space around the motor to permit free flow of ventilating air and to maintain an ambient temperature not over 40ºC. Where a choice of locations is possible, install the motor so that it will be subjected to the least amount of dirt, dust, liquids, or other harmful materials. Mount the m ...
Real-time adjustable gate current control IC solves dv/dt
Real-time adjustable gate current control IC solves dv/dt

... lower and lower switching losses. On the other hand EMI problems and side effects increase, if one fully uses the offered switching performance. It is state of the art to solve the tradeoff between switching performance and EMI with the design of the gate resistor including an optional gate-emitter ...
Real-time adjustable gate current control IC solves dv/dt
Real-time adjustable gate current control IC solves dv/dt



... The phenomenon of voltages and currents on motor and generator shafts has been known for the past 100 years. It affects motors, hydro generators and turbo generators. There has been an increase in occurrences and intensity of shaft current damages as machines became larger, particularly on high spee ...
Drive Solutions for the Global Cement Industry
Drive Solutions for the Global Cement Industry

Noise Reduction Techniques
Noise Reduction Techniques

< 1 ... 77 78 79 80 81 82 83 84 85 ... 213 >

Brushed DC electric motor



A brushed DC motor is an internally commutated electric motor designed to be run from a direct current power source. Brushed motors were the first commercially important application of electric power to driving mechanical energy,and DC distribution systems were used for more than 100 years to operate motors in commercial and industrial buildings. Brushed DC motors can be varied in speed by changing the operating voltage or the strength of the magnetic field. Depending on the connections of the field to the power supply, the speed and torque characteristics of a brushed motor can be altered to provide steady speed or speed inversely proportional to the mechanical load. Brushed motors continue to be used for electrical propulsion, cranes, paper machines and steel rolling mills. Since the brushes wear down and require replacement, brushless DC motors using power electronic devices have displaced brushed motors from many applications