IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
... The evolution of Electric Vehicles (EV) creates a global push and provides better replacement of the fuel based vehicles. The Vehicles are charged by batteries and the power flow during starting and braking operations can be designed by Bidirectional quasi Z Source Inverter. The power (SDP) by 15% o ...
... The evolution of Electric Vehicles (EV) creates a global push and provides better replacement of the fuel based vehicles. The Vehicles are charged by batteries and the power flow during starting and braking operations can be designed by Bidirectional quasi Z Source Inverter. The power (SDP) by 15% o ...
DEC Module 50/5 Operating Instructions
... Repairs may be made by authorized personnel only or by the manufacturer. Improper repairs can result in substantial dangers for the user ...
... Repairs may be made by authorized personnel only or by the manufacturer. Improper repairs can result in substantial dangers for the user ...
Verkaufsunterlagen
... mounting points comply with EN 50347 specifications to ensure compatibility with standardised IEC frame motor applications and full interchangeability with IE2 standardised asynchronous motors. Envelope dimensions lie within the limits for IE2 motors as recommended in DIN V 42673 (07/2011). The moto ...
... mounting points comply with EN 50347 specifications to ensure compatibility with standardised IEC frame motor applications and full interchangeability with IE2 standardised asynchronous motors. Envelope dimensions lie within the limits for IE2 motors as recommended in DIN V 42673 (07/2011). The moto ...
AC Motors
... Do not lift the motor and its driven load by the motor lifting hardware. The motor lifting hardware is adequate for lifting only the motor. Disconnect the load (gears, pumps, compressors, or other driven equipment) from the motor shaft before lifting the motor. Caution: If eye bolts are used for lif ...
... Do not lift the motor and its driven load by the motor lifting hardware. The motor lifting hardware is adequate for lifting only the motor. Disconnect the load (gears, pumps, compressors, or other driven equipment) from the motor shaft before lifting the motor. Caution: If eye bolts are used for lif ...
uniblock ubsf
... The construction principle of the PILLER UNIBLOCK system combines a motor and a generator in one, three-phase synchronous machine. The windings of both components are incorporated in a shared stator and are excited by a common rotor. The energy transfer from the motor to the generator takes place vi ...
... The construction principle of the PILLER UNIBLOCK system combines a motor and a generator in one, three-phase synchronous machine. The windings of both components are incorporated in a shared stator and are excited by a common rotor. The energy transfer from the motor to the generator takes place vi ...
automated smart sowing machine for port trays (agri robot)
... appliance for our society as India is the 2nd largest producer of vegetable crops in the world. The developed model avoids the wastage of precious seeds as it is designed to pick and drop only one seed at an instant, consequently it increases the percentage of germination which leads to profit to th ...
... appliance for our society as India is the 2nd largest producer of vegetable crops in the world. The developed model avoids the wastage of precious seeds as it is designed to pick and drop only one seed at an instant, consequently it increases the percentage of germination which leads to profit to th ...
ExamView - POE Practice Test
... Identify one or more choices that best complete the statement or answer the question. 28. Identify which of these circuits is a series circuit (there may be more than one shown!) ...
... Identify one or more choices that best complete the statement or answer the question. 28. Identify which of these circuits is a series circuit (there may be more than one shown!) ...
KE2316991705
... link part of the BTB system. Boost converter will control the battery current and the battery power will be used as a secondary power to drive the electric motor. In this paper, a new circuit topology is presented, which is composed of an indirect matrix converter (IMC) and a dc/dc boost converter t ...
... link part of the BTB system. Boost converter will control the battery current and the battery power will be used as a secondary power to drive the electric motor. In this paper, a new circuit topology is presented, which is composed of an indirect matrix converter (IMC) and a dc/dc boost converter t ...
User and Installation Manual
... power leads. It is recommended that this shielding be done with a highly permeable material, such as braided steel. Most of the emissions are electromagnetic in nature, caused by the high currents required by these drives. When shielding the high power conductors, do not wrap the sensor wires for th ...
... power leads. It is recommended that this shielding be done with a highly permeable material, such as braided steel. Most of the emissions are electromagnetic in nature, caused by the high currents required by these drives. When shielding the high power conductors, do not wrap the sensor wires for th ...
Autotransformers - ELHAND Transformatory
... in high-power drives, where switching from the star into stator winding triangle is technically difficult. ...
... in high-power drives, where switching from the star into stator winding triangle is technically difficult. ...
Data Debugging in Power System Operations Using Gap Statistic A
... Compared with other commonly used motors, switched reluctance motor [3-5] possesses many merits, such as simple and rigid structure, high generating torque and acceleration capabilities, suitable for high speed operation, simple drive circuit and switching control. In particular, its rotor is not eq ...
... Compared with other commonly used motors, switched reluctance motor [3-5] possesses many merits, such as simple and rigid structure, high generating torque and acceleration capabilities, suitable for high speed operation, simple drive circuit and switching control. In particular, its rotor is not eq ...
Quad DMOS Full Bridge PWM Motor Driver A3988
... The A3988 is a quad DMOS full-bridge driver capable of driving up to two stepper motors or four DC motors. Each full-bridge output is rated up to 1.2 A and 36 V. The A3988 includes fixed off-time pulse width modulation (PWM) current regulators, along with 2- bit nonlinear DACs (digital-to-analog con ...
... The A3988 is a quad DMOS full-bridge driver capable of driving up to two stepper motors or four DC motors. Each full-bridge output is rated up to 1.2 A and 36 V. The A3988 includes fixed off-time pulse width modulation (PWM) current regulators, along with 2- bit nonlinear DACs (digital-to-analog con ...
How to control and monitor up to 16 via an HM
... The only communication parameter that must be changed for each Motor Insight is the Modbus node address. The “Motor 1” button will access the control, configuration, and status pages for the Motor Insight with Modbus serial address 1. The “Motor 2” button will access the control, configuration, and ...
... The only communication parameter that must be changed for each Motor Insight is the Modbus node address. The “Motor 1” button will access the control, configuration, and status pages for the Motor Insight with Modbus serial address 1. The “Motor 2” button will access the control, configuration, and ...
PREOBRAZOVATEL
... - remote – applying commands through network interface from PCS MCB/CCB; automatic excitation by command from turbine regulator “Frequency over ...
... - remote – applying commands through network interface from PCS MCB/CCB; automatic excitation by command from turbine regulator “Frequency over ...
Meters designed for the way you work
... Working on VSDs/VFDs: Take accurate voltage, current and frequency measurements on the output side of the drive at either the drive itself or at the motor terminals. ...
... Working on VSDs/VFDs: Take accurate voltage, current and frequency measurements on the output side of the drive at either the drive itself or at the motor terminals. ...
Overload Relays
... 5. A ____________ strip uses two dissimilar metals bonded together. 6. An overload relay can be _____________ once the overload is removed. 7. Advantages common to most electronic overload relays include: ...
... 5. A ____________ strip uses two dissimilar metals bonded together. 6. An overload relay can be _____________ once the overload is removed. 7. Advantages common to most electronic overload relays include: ...
Technical guide No. 4, Guide to variable speed drives
... in stator windings forms the current and magnetic flux. The direction of this flux can be determined using the right hand rule from the stator current. By changing the direction of the voltage in stator windings, the direction of the flux can also be changed. By changing the voltage direction in the ...
... in stator windings forms the current and magnetic flux. The direction of this flux can be determined using the right hand rule from the stator current. By changing the direction of the voltage in stator windings, the direction of the flux can also be changed. By changing the voltage direction in the ...
Extending battery life in smart locks
... TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguar ...
... TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguar ...
Brushed DC electric motor
A brushed DC motor is an internally commutated electric motor designed to be run from a direct current power source. Brushed motors were the first commercially important application of electric power to driving mechanical energy,and DC distribution systems were used for more than 100 years to operate motors in commercial and industrial buildings. Brushed DC motors can be varied in speed by changing the operating voltage or the strength of the magnetic field. Depending on the connections of the field to the power supply, the speed and torque characteristics of a brushed motor can be altered to provide steady speed or speed inversely proportional to the mechanical load. Brushed motors continue to be used for electrical propulsion, cranes, paper machines and steel rolling mills. Since the brushes wear down and require replacement, brushless DC motors using power electronic devices have displaced brushed motors from many applications