• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Integrated compact units - AEG Industrial Engineering
Integrated compact units - AEG Industrial Engineering

... means to boost efficiency. As gas turbines cannot start without external means, a start-up device is necessary driving the main generator via a static frequency converter while the main generator is working as a motor. ...
EPOS2 Module 36/2 Hardware Reference
EPOS2 Module 36/2 Hardware Reference

... maxon motor control’s EPOS2 Module 36/2 is a small-sized, full digital, smart motion controller. It is designated for the use as plug-in module in customer-specific motherboards for single axis or multi axes motion control systems. Due to its flexible and high efficient power stage, the EPOS2 Module ...
TEXT 8 - Камышинский технологический институт
TEXT 8 - Камышинский технологический институт

... electrons. It is the movement of these particles which produces the effects of heat and light. The pressure that forces these atomic particles to move, the effects they encounter opposition and how these forces are controlled are some of the principles of electricity. Accepted atomic theory states t ...
Multi Pad for NLX/iMD Installation Manual
Multi Pad for NLX/iMD Installation Manual

... The “Multi Pad” system is featured to integrate with a micromotor (NLX BF) and Multi Function Ultrasonic Scaler (Varios 170(OPTION)) in one system. This manual is for installation and setup of the Multi Pad and the micromotor (NLX BF). For installation of the Multi Function Ultrasonic Scaler (Varios ...


... available. While BGA packages are best suited for large-scale projects where absolutely minimum PCB occupancy is required, there is often debate on whether TH packages or SMT packages should be used for smaller projects. Many electronics hobbyists still prefer TH packages because TH components can b ...
Ironless vacuum linear motor series
Ironless vacuum linear motor series

Microsoft Word
Microsoft Word

... motor to overcome the heating effects at low speeds and high-current draw. ...
Cast Coil Transformers
Cast Coil Transformers

... and insulated on both sides by a thin layer of organic material (carlyte). The cutting and assembly is performed at 45° angles using the step lap method to reduce losses, excitation current, and magnetic noise. ...
Progress in On-Line Measurement of PD in G.C. Stone I. Culbert
Progress in On-Line Measurement of PD in G.C. Stone I. Culbert

... up to about 600 kHz. Future VS-PWM drives are likely to have shorter switching times and higher switching voltages, making the situation worse. One reason that PD measurement is difficult with VSPWM drives is that the frequency content of the impulse voltages (which are about 1,000 times or 60 dB hi ...
Development and Implementation of Composite Load Model in WECC
Development and Implementation of Composite Load Model in WECC

... Systems used in commercial buildings. For large motors, we used manufacturer’s published data to develop model parameters. WECC uses different data sets for “commercial” / “residential” substations versus “industrial” loads. For “commercial” and “residential” substations, which are majority of syste ...
LAB 5 Magnetic Induction & Lenz’s Law
LAB 5 Magnetic Induction & Lenz’s Law

... off” in a second nearby coil. After you have made your prediction, do the experiment and report on your results. • Experiment and answer the following questions: How does the current induced in the first coil change if you increase or decrease the voltage supplied the second coil? ...
Altivar ® 31 Adjustable Speed AC Drives
Altivar ® 31 Adjustable Speed AC Drives

... • 1 to 20 hp (0.75 to 15 kW), 525/575/600 V, three-phase input Industrial users and OEMs who specialize in material handling, pump, fan, packing, packaging, and general purpose motor control applications will find the features and functions of the ATV31 drive controller well suited for their use. ...
PDF (1.45 MB)
PDF (1.45 MB)

... corresponding to the luminous flux rank. Mitsubishi Electric’s design is able to handle up to six different ranks. 3.2 Feed-forward control The LED driver must be designed assuming that the supply voltage varies. Constant current control is generally performed by the feed-back system for the output ...
W.S. Chang, T.A. Parlikar, M.D. Seeman, D.J. Perreault, J.G. Kassakian, and T.A. Keim, “A New Electromagnetic Valve Actuator,” 2002 IEEE Workshop on Power Electronics in Transportation, Auburn Hills, MI, October 2002, pp. 109-118.
W.S. Chang, T.A. Parlikar, M.D. Seeman, D.J. Perreault, J.G. Kassakian, and T.A. Keim, “A New Electromagnetic Valve Actuator,” 2002 IEEE Workshop on Power Electronics in Transportation, Auburn Hills, MI, October 2002, pp. 109-118.

... fixed relative to the crankshaft position. The valves are actuated with cams that are located on a belt-driven camshaft, and the shape of these cams is determined by considering a tradeoff between engine speed, power, and torque requirements, as well as vehicle fuel consumption. This optimization re ...
Structures, Unions, and Typedefs
Structures, Unions, and Typedefs

... CS-2303, C-Term 2010 ...
Analytical Calculation of Magnetic Field Distribution and Stator Iron
Analytical Calculation of Magnetic Field Distribution and Stator Iron

Motor Mind B enhanced Motor Controller Data
Motor Mind B enhanced Motor Controller Data

... update (PWM = PI/2 ). So making the PISCALAR larger reduces the PWM (divides it by 2), decreasing it increases the PWM (doubles it). Therefore, the PISCALAR will have a large effect on the way PI mode drives the motor. If your motor is ramping (zooms up to top speed, then back to zero) increase the ...
Topic 12_2__Alternating current
Topic 12_2__Alternating current

...  = 2fNBA sin 2ft  = 0 sin 2ft  = NBA sin t induced emf (rotating coil, N loops, constant B-field)  = 2fNBA sin 2ft  = 0 sin 2ft ( Where 0 = 2fNBA ) ...
chapter 1 - UniMAP Portal
chapter 1 - UniMAP Portal

... • A medium that connects all the components and allows current to flow. Examples: • copper wire • bread board • What else??? ...
s-cab_quickstart - the NCE Information Station
s-cab_quickstart - the NCE Information Station

BASIC SET-UP GUIDE ––– timbuk2 ESC
BASIC SET-UP GUIDE ––– timbuk2 ESC

magnetically coupled circuit
magnetically coupled circuit

步进电机的物理原理
步进电机的物理原理

... Stepping motors come in a wide range of angular resolution. The coarsest motors typically turn 90 degrees per step, while high resolution permanent ...
SELCO T-Line Generator Control, Protection and Monitoring Short Form Catalogue
SELCO T-Line Generator Control, Protection and Monitoring Short Form Catalogue

... with conventional governors (and electronic speed controllers via an intermediate motorized potentiometer). The other for connection directly to all types of electronic speed controllers. For synchronizing SELCO also supplies Synchroscopes for illuminated indication of the phase difference. Also ava ...
Induction Motors
Induction Motors

... In developing the model of induction machines, following aspects will differ from those of synchronous machines:  The d- and q-axis equivalent circuits are identical as the rotor has symmetrical structure.  The rotor speed is not fixed but varies with load. This has an impact on the selection of t ...
< 1 ... 45 46 47 48 49 50 51 52 53 ... 213 >

Brushed DC electric motor



A brushed DC motor is an internally commutated electric motor designed to be run from a direct current power source. Brushed motors were the first commercially important application of electric power to driving mechanical energy,and DC distribution systems were used for more than 100 years to operate motors in commercial and industrial buildings. Brushed DC motors can be varied in speed by changing the operating voltage or the strength of the magnetic field. Depending on the connections of the field to the power supply, the speed and torque characteristics of a brushed motor can be altered to provide steady speed or speed inversely proportional to the mechanical load. Brushed motors continue to be used for electrical propulsion, cranes, paper machines and steel rolling mills. Since the brushes wear down and require replacement, brushless DC motors using power electronic devices have displaced brushed motors from many applications
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report