• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
3-Phase BLDC Motor Control with Sensorless Back EMF Zero
3-Phase BLDC Motor Control with Sensorless Back EMF Zero

... Figure 3-1. BLDC Motor - Cross Section The motor can have more then just one pole-pair per phase. This defines the ratio between the electrical revolution and the mechanical revolution. The BLDC motor shown has three pole-pairs per phase which represent three electrical revolutions per one mechanica ...
.Connection and Operation (Speed Control)
.Connection and Operation (Speed Control)

07-Voltmeters
07-Voltmeters

... Some voltmeters are intended for use in direct current (DC) circuits; others are designed for alternating current (AC) circuits. ...
Frequently Asked Questions (FAQs)
Frequently Asked Questions (FAQs)

... Circuit Protectors (MCP), require that the VFD be listed as a combination in order to be used as a motor branch circuit disconnect or for branch circuit protection. In addition, most VFDs do not have combination ratings above 5kA with MCPs or circuit breakers. It may be possible to achieve a high SC ...
Installation & Operating Manual
Installation & Operating Manual

... CAUTION: Indicates a potentially hazardous situation which, if not avoided, could result in damage to property. PRECAUTIONS ...
You can guess which fuse is bad… or you can try this
You can guess which fuse is bad… or you can try this

Lab 7 – INDUCTORS AND LR CIRCUITS
Lab 7 – INDUCTORS AND LR CIRCUITS

... Activity 1-3: Magnetic Fields and Inductors, Part II You have now observed that a current through a coil of wire creates a magnetic field inside and around the coil. You have also observed that a changing magnetic field created by a moving magnet inside a coil can induce a voltage across the coil. I ...
Power Supply Module 230 V MDP 102-1 1 Overview
Power Supply Module 230 V MDP 102-1 1 Overview

A novel direct torque control (DTC) method
A novel direct torque control (DTC) method

Alternator Secrets
Alternator Secrets

CATALOGUE July 2014 Stepper Motor Electronics
CATALOGUE July 2014 Stepper Motor Electronics

... Stepper motor technology for special requirements: Stepper motor technology is particularly suitable for precision applications under extreme environmental conditions. Whether vacuum, cryo environment, high temperature or under the influence of radioactivity - the phytron motor series are tough and ...
Document
Document

... locomotive. The power for these motors is obtained from 72+1 V control voltage fed by aux. generator/voltage regulator or from 64V battery. The DC motor requires excessive maintenance because of commutation and the reliability is also very poor. 0.2 This specification is intended to serve as a guide ...
Manual FB F14W47_MFB_F_SV.ai
Manual FB F14W47_MFB_F_SV.ai

... must be drilled at what becomes the lowest point in the installed fan, according to the selected outlet direc on. In the case of professional installa on, too, fans can produce harmful noise levels. It should also be noted that specified noise data (see separate product sheet) can be altered by the ...
PDF
PDF

... common mode voltage across the motor windings. The main problems are motor bearing and motor winding insulation breakdown. Multilevel power converter structure has been introduced as an alternative in high power and medium voltage situations such as laminators, mills, conveyors, pumps, fans, blowers ...
AH293  LOW VOLTAGE HALL-EFFECT SMART FAN MOTOR CONTROLLER
AH293 LOW VOLTAGE HALL-EFFECT SMART FAN MOTOR CONTROLLER

... the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance w ...
Magnetic effect of current
Magnetic effect of current

Lexium™ 32i Integrated drives Motion control
Lexium™ 32i Integrated drives Motion control

... The Lexium 32i product range of integrated drives covers motor power ratings between 0.4 kW and 2.1 kW with three types of power supply: bb 110…120 V single-phase, from 0.4 kW to 0.75 kW (BMIpppTppp) bb 200…240 V single-phase, from 0.7 kW to 1.3 kW (BMIpppTppp) bb 208…480 V three-phase, from 0.4 kW ...
section 15172
section 15172

... rejected. 6 pulse, passive filters, and 12-pulse rectifiers are not acceptable and ...
Question Bank 1. Electromagnetism 2. Magnetic Effects
Question Bank 1. Electromagnetism 2. Magnetic Effects

... (c) If the solenoid is suspended freely, in which direction is it likely to point ? (d) State three ways of increasing the magnetic strength of a solenoid. Ans. (a) Solenoid is an insulated copper coil, wound on cylindrical cardboard, such that its length is greater than its diameter and it behaves ...
PLUS+1 Inverter Family Technical Information Rev AA
PLUS+1 Inverter Family Technical Information Rev AA

... 1.1 PLUS+1 Inverter Family Technical Information.............................................................................. 5 1.2 What information is in this manual?.................................................................................................. 5 1.3 What information is in prod ...
09221020
09221020

... connected assembly of solar cells, also called photovoltaic cells which are solid state devices that can convert solar energy directly into electrical energy through quantum mechanical transitions. They are noiseless and pollution-free with no rotating parts and need minimum maintenance. The electri ...
Advanced Generator Protection and Monitoring Using
Advanced Generator Protection and Monitoring Using

Design and construction of a polygon
Design and construction of a polygon

... and developed in the laboratory. The winding details of the developed autotransformers are given in Appendix B. Various tests have been conducted under Three-phase voltages with phase to phase rms value of 380 volts and an equivalent resistive load. Input voltage and current waveforms and harmonic s ...
PLC Trainer PLCE www.edibon.com Technical Teaching Equipment
PLC Trainer PLCE www.edibon.com Technical Teaching Equipment

... The PLCE is a PLC trainer designed by EDIBON. It allows the user to learn about logic programming without any background knowledge or experience. The PLCE includes digital and analog inputs and outputs, switches, push buttons, potentiometers, etc., allocated in the front panel of the box. This train ...
SHAFT GROUNDING ENGINEERING SPECIFICATION FOR AC
SHAFT GROUNDING ENGINEERING SPECIFICATION FOR AC

< 1 ... 25 26 27 28 29 30 31 32 33 ... 213 >

Brushed DC electric motor



A brushed DC motor is an internally commutated electric motor designed to be run from a direct current power source. Brushed motors were the first commercially important application of electric power to driving mechanical energy,and DC distribution systems were used for more than 100 years to operate motors in commercial and industrial buildings. Brushed DC motors can be varied in speed by changing the operating voltage or the strength of the magnetic field. Depending on the connections of the field to the power supply, the speed and torque characteristics of a brushed motor can be altered to provide steady speed or speed inversely proportional to the mechanical load. Brushed motors continue to be used for electrical propulsion, cranes, paper machines and steel rolling mills. Since the brushes wear down and require replacement, brushless DC motors using power electronic devices have displaced brushed motors from many applications
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report