BDTIC www.BDTIC.com/infineon Efficient Solutions for Industrial Motor Control and Drives
... Infineon offers gate driver ICs, discrete IGBTs, integrated modules and high-power modules across the entire power class range for high-voltage drives. No matter what the power needs of your actual application, we provide the optimized, cost‑effective solution. The Infineon portfolio for high-voltag ...
... Infineon offers gate driver ICs, discrete IGBTs, integrated modules and high-power modules across the entire power class range for high-voltage drives. No matter what the power needs of your actual application, we provide the optimized, cost‑effective solution. The Infineon portfolio for high-voltag ...
Trip Indication Relays - E
... relay, communication and control system operations. The TIR contacts are also used to activate alarm and/or annunciator contacts. The E-MAX Trip Indication Relays detect the presence of current in power system circuit breaker trip coils. The TIR has a current coil designed for installation in circui ...
... relay, communication and control system operations. The TIR contacts are also used to activate alarm and/or annunciator contacts. The E-MAX Trip Indication Relays detect the presence of current in power system circuit breaker trip coils. The TIR has a current coil designed for installation in circui ...
DC30 Servo Driver
... MCS DC30 is a MOSFET BRIDGE Drives. It based on digital control, voltage control and analogy control technologies. It is 8 layers PCB. Input voltage 24 to 80VDC (DC30) or 24 to 36VDC (DC30_36). Control of DC motors up to 500W is available. The drives are suitable for use in a wide range of applicati ...
... MCS DC30 is a MOSFET BRIDGE Drives. It based on digital control, voltage control and analogy control technologies. It is 8 layers PCB. Input voltage 24 to 80VDC (DC30) or 24 to 36VDC (DC30_36). Control of DC motors up to 500W is available. The drives are suitable for use in a wide range of applicati ...
Sensorless Control for a Switched Reluctance Wind Generator
... where N is the number of samples in a state of commutation, ii is the ith sampled current, and iN is the last current sample. Moreover, z0 = 0, and the term [N (N 2 − 1)]−1 can be obtained from a lookup table (no more than 16 terms), avoiding a mathematical division that requires several instruction ...
... where N is the number of samples in a state of commutation, ii is the ith sampled current, and iN is the last current sample. Moreover, z0 = 0, and the term [N (N 2 − 1)]−1 can be obtained from a lookup table (no more than 16 terms), avoiding a mathematical division that requires several instruction ...
application guideline for electric motor drive equipment for natural
... to know how to specify the electric motor drive system and assure that the system design can support the power and speed range for the application. In the last ten years, electric motor driven compression has become more common in the natural gas industry. Many of the components of an electric motor ...
... to know how to specify the electric motor drive system and assure that the system design can support the power and speed range for the application. In the last ten years, electric motor driven compression has become more common in the natural gas industry. Many of the components of an electric motor ...
Distributed I/O SIMATIC ET 200
... PM-DFx power module which must be connected to the left of the first motor starter. • The load voltage is fed in at the first (left) TM-xxxxS32 terminal module of a motor starter. The other TM-xxxxS31 terminal modules are automatically supplied with power through the integrated power bus when they a ...
... PM-DFx power module which must be connected to the left of the first motor starter. • The load voltage is fed in at the first (left) TM-xxxxS32 terminal module of a motor starter. The other TM-xxxxS31 terminal modules are automatically supplied with power through the integrated power bus when they a ...
Form-Wound Coils Random
... The coil winding process begins with skeining (looping) of the magnet wire. Because of the difficulty to form wire of high width-to-thickness ratio, several wires in parallel may make one turn. Individual turns are arranged in precise location with respect to each other. That is, turn one is always ...
... The coil winding process begins with skeining (looping) of the magnet wire. Because of the difficulty to form wire of high width-to-thickness ratio, several wires in parallel may make one turn. Individual turns are arranged in precise location with respect to each other. That is, turn one is always ...
Motion control Lexium 32i integrated drives
... 0.4 kW and 2.1 kW with three types of power supply: bb 110…120 V single-phase, from 0.4 kW to 0.75 kW (BMIpppTppp) bb 200…240 V single-phase, from 0.7 kW to 1.3 kW (BMIpppTppp) bb 208…480 V three-phase, from 0.4 kW to 2.1 kW (BMIpppPppp) Compliance with international standards and certifications The ...
... 0.4 kW and 2.1 kW with three types of power supply: bb 110…120 V single-phase, from 0.4 kW to 0.75 kW (BMIpppTppp) bb 200…240 V single-phase, from 0.7 kW to 1.3 kW (BMIpppTppp) bb 208…480 V three-phase, from 0.4 kW to 2.1 kW (BMIpppPppp) Compliance with international standards and certifications The ...
Choosing the Right Stator Bar for Your Next Rewind
... weaker area in the coil design and winding failures are often due to a surge and failure of the turn insulation. The choice of a multiturn coil or single turn bar is often dictated by the owner, perhaps based on previous bad experience, such as an untimely failure. Although rewinds can include a new ...
... weaker area in the coil design and winding failures are often due to a surge and failure of the turn insulation. The choice of a multiturn coil or single turn bar is often dictated by the owner, perhaps based on previous bad experience, such as an untimely failure. Although rewinds can include a new ...
User manual
... torque-, speed- and/or position-control, and to drive brushless synchronous servo motors, asynchronous motors and three-phase stepper motors. The rated voltage of the motors must be higher than, or at least equal to, the DC link voltage supplied by the servo amplifier. The digital servo amplifier Je ...
... torque-, speed- and/or position-control, and to drive brushless synchronous servo motors, asynchronous motors and three-phase stepper motors. The rated voltage of the motors must be higher than, or at least equal to, the DC link voltage supplied by the servo amplifier. The digital servo amplifier Je ...
March Pump General Installation Guide
... Install the pump as near to the suction source and as low as possible. Suction must be flooded. When using an elbow, valve, etc., the suction must have straight piping in length at least five (5) times the diameter of the pipe. 3. Suction piping should not be smaller than the pump suction size and p ...
... Install the pump as near to the suction source and as low as possible. Suction must be flooded. When using an elbow, valve, etc., the suction must have straight piping in length at least five (5) times the diameter of the pipe. 3. Suction piping should not be smaller than the pump suction size and p ...
Sensor-less Three-phase Brushless DC Motor Controller
... the microcontroller is lost, the motor can continue running at a pre-defined fixed duty cycle of 25%, 50%, 75% or 100%. ...
... the microcontroller is lost, the motor can continue running at a pre-defined fixed duty cycle of 25%, 50%, 75% or 100%. ...
Short-circuit current ratings 3MB
... An industrial control panel is an assembly that consists of at least two components. They may be “power” components such as motor controllers, overload relays, fused disconnect switches, and circuit breakers, or they may be “control circuit” components such as push buttons, pilot lights, selector sw ...
... An industrial control panel is an assembly that consists of at least two components. They may be “power” components such as motor controllers, overload relays, fused disconnect switches, and circuit breakers, or they may be “control circuit” components such as push buttons, pilot lights, selector sw ...
Chapter 2 - Sacramento - California State University
... 4. DESIGN OF FAN CONTROL SYSTEM…………………………...…………...26 4.1 Configuring ADC in ATmega168………………………………………....26 ...
... 4. DESIGN OF FAN CONTROL SYSTEM…………………………...…………...26 4.1 Configuring ADC in ATmega168………………………………………....26 ...
Electrical Installations Lab AEL-1 Advanced Electrical Laboratories (AEL-LABS):
... SCADA Systems - SCADA. Control Software: Software designed to control different applications that require an advance control system, such as generation systems remote control, distribution systems with control over power flows and isolating switches, etc. It is included if the application required i ...
... SCADA Systems - SCADA. Control Software: Software designed to control different applications that require an advance control system, such as generation systems remote control, distribution systems with control over power flows and isolating switches, etc. It is included if the application required i ...
Tram Service in Urban Mass Public Transport
... Electric equipment – traction drive • Traction DC motors are the same but have insulation in class H. Output is higher44 kW • TM are supplied with electronic pulse converters – Energy saving – Easier mentanance ~ minimum kontacts Petr Sýkora pro X14EPT ...
... Electric equipment – traction drive • Traction DC motors are the same but have insulation in class H. Output is higher44 kW • TM are supplied with electronic pulse converters – Energy saving – Easier mentanance ~ minimum kontacts Petr Sýkora pro X14EPT ...
Brushed DC electric motor
A brushed DC motor is an internally commutated electric motor designed to be run from a direct current power source. Brushed motors were the first commercially important application of electric power to driving mechanical energy,and DC distribution systems were used for more than 100 years to operate motors in commercial and industrial buildings. Brushed DC motors can be varied in speed by changing the operating voltage or the strength of the magnetic field. Depending on the connections of the field to the power supply, the speed and torque characteristics of a brushed motor can be altered to provide steady speed or speed inversely proportional to the mechanical load. Brushed motors continue to be used for electrical propulsion, cranes, paper machines and steel rolling mills. Since the brushes wear down and require replacement, brushless DC motors using power electronic devices have displaced brushed motors from many applications