• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DES 70/10 Operating Instructions
DES 70/10 Operating Instructions

... Important: If the motor vibrates or becomes loud, the selected amplification is too high and the potentiometer P4 must be readjusted until the instability of the drive’s closed loop ceases under all loads. Adjust set value to zero, e.g. by short-circuiting the set value. Then, with the potentiometer ...
Microelectromechanical Devices
Microelectromechanical Devices

... In this case the three upper devices (Q1, Q3, and Q5) are turned on sequentially in the middle of the positive half-cycles of the phase voltages and the lower devices (Q2,Q4 and Q6) are chopped sequentially in the middle of the negative half-cycles of the phase voltages to achieve the desired curren ...
Series and Parallel Circuits
Series and Parallel Circuits

... form a loop ...
EET 3092 SWITCHGEAR AND PROTECTION
EET 3092 SWITCHGEAR AND PROTECTION

Harmonic Design - GE Industrial Solutions
Harmonic Design - GE Industrial Solutions

Clicker questions_farady_induction
Clicker questions_farady_induction

Tariff Rule No. 2 Character of Servic
Tariff Rule No. 2 Character of Servic

... more than 200 KVA or above 600 volts must be approved by the Company. For such applications, the Company may require that the customer furnish an increment starting device capable of limiting the current increment between successive steps to 3.3 amperes per running ampere and limiting the total curr ...
dynamic model of pm synchronous motors
dynamic model of pm synchronous motors

... inductance value at a small current and may not be suitable to predict characteristics of the motor. The small signal inductance value may be lower than unsaturated inductance value since permeability of iron decreases at very low flux densities [8]. Since inductance is also subject to saturation, w ...
Quantum Hall Effect Manual
Quantum Hall Effect Manual

... the coil with a superconducting shunt, any current present in the coil will circulate indefinitely, thus maintaining an extremely stable, perpetual magnetic field. However, the inclusion of this superconducting shunt creates a problem: any current we attempt to put through the coil will simply trave ...
Vehicle Power Plant and Transmission Characteristics
Vehicle Power Plant and Transmission Characteristics

Table showing DTMF Low and High frequency tones and decoded
Table showing DTMF Low and High frequency tones and decoded

Focus 3 - Emerson Industrial
Focus 3 - Emerson Industrial

TSB 2013.08.006
TSB 2013.08.006

... MOUNTING – The larger-sized manual circuit breakers (50 and 70 Amp) sold by Hannay Reels can be purchased with a convenient mounting bracket. Mount the breaker away from any heat source such as an exhaust manifold or radiator. Since this style of breaker must be manually reset if tripped, it should ...
Development of Environment-Friendly Latching Relay 1
Development of Environment-Friendly Latching Relay 1

... Since mechanical lock types usually have high cost due to their complex structures, electromagnetic lock types using permanent magnets are more commonly used. They are also called polarized relays because the (+) pole of the driving coil is determined by specifications. JSL relays are classified as ...
an1088 application note
an1088 application note

Use of 690 V for LV industrial distribution network to save
Use of 690 V for LV industrial distribution network to save

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... 4.1 Open Loop Response At Normal Condition: At normal and healthy condition i.e. when there is no fault in the inverter circuit, the current and voltage remain unchanged for it is the flux component of the stator current. The speed and torque are also continuous with time as motor is running smoothl ...
Self Inductance.
Self Inductance.

... has an inductance of 0.20H. When the switch S is open, the current falls from 5.0A to zero in 1.0s. a. What is the induced voltage? b. What is the resistance, R, of the coil c. What is the energy stored when S is ...
Rotary Phase Converters
Rotary Phase Converters

International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.1, pp. 1716-1726
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.1, pp. 1716-1726

... In the present paper, a three-phase SCIM rated 3 HP, 220 V, 1430 RPM is fed by a sinusoidal PWM inverter has been considered for analysis purpose. The sinusoidal reference wave base frequency is used 50 Hz while the triangular carrier wave's frequency is calculated and set to 1650 Hz. The modulation ...
ABB micro drives - ACS55, 0.25 to 3 hp/0.18 to 2.2 kW, Catalog
ABB micro drives - ACS55, 0.25 to 3 hp/0.18 to 2.2 kW, Catalog

... ACS55 micro drives are designed for use in a wide variety of simple machinery applications where only 115 V single phase power is available. Feed-thru wiring with power leads entering at the top and motor cables exiting at the bottom allows for easy replacement of contactors and motor starters. Thes ...
Power Tool Safety Terms
Power Tool Safety Terms

... Double-Insulated (DI) – a form of electrical protection featuring two separate insulation systems to help protect against electrical shock from internal malfunctions. DI tools have no provision for grounding (no third grounding prong), and are equipped with a polarized two-prong plug (See “Polarized ...
200400045 VECTRON ELEKTRONIK MANUAL
200400045 VECTRON ELEKTRONIK MANUAL

... gives information on irregularities in operation; the last four trips show the accurate operating point of the drive. ...
FPGA Based Speed Control of Three
FPGA Based Speed Control of Three

... Abstract — In this paper a digital speed control strategy for three-phase induction motor is implemented. This strategy depends on varying the stator voltage to control the speed of induction motor. The system consists of six bidirectional switches. The digital control strategy uses saw-tooth wavefo ...
Catheter Guidewire Control System
Catheter Guidewire Control System

< 1 ... 110 111 112 113 114 115 116 117 118 ... 213 >

Brushed DC electric motor



A brushed DC motor is an internally commutated electric motor designed to be run from a direct current power source. Brushed motors were the first commercially important application of electric power to driving mechanical energy,and DC distribution systems were used for more than 100 years to operate motors in commercial and industrial buildings. Brushed DC motors can be varied in speed by changing the operating voltage or the strength of the magnetic field. Depending on the connections of the field to the power supply, the speed and torque characteristics of a brushed motor can be altered to provide steady speed or speed inversely proportional to the mechanical load. Brushed motors continue to be used for electrical propulsion, cranes, paper machines and steel rolling mills. Since the brushes wear down and require replacement, brushless DC motors using power electronic devices have displaced brushed motors from many applications
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report