• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Investigation of a Power Factor Correction Fed
Investigation of a Power Factor Correction Fed

Types of overcurrent protective devices 1.9MB
Types of overcurrent protective devices 1.9MB

... LVPCBs 1. May be required upstream of MCCBs and ICCBs (which have instantaneous trips or overrides) for selective coordination capabilities 2. Can "hold-in" on faults for up to 30 cycles (.5 seconds) in order to achieve coordination with ...
Calculating the main and leakage inductance matrix of the 3
Calculating the main and leakage inductance matrix of the 3

CENTRAL STAFF TRAINING AND RESEARCH INSTITUTE  MINISTRY OF LABOUR AND EMPLOYMENT
CENTRAL STAFF TRAINING AND RESEARCH INSTITUTE MINISTRY OF LABOUR AND EMPLOYMENT

... voltage, current, resistance, Verification of law of series and with dimensioning. and ...
hAvOC pRO ESC bASIC SET-up GuIDE hAvOC pRO CuSTOM
hAvOC pRO ESC bASIC SET-up GuIDE hAvOC pRO CuSTOM

DC GENERATOR
DC GENERATOR

ee6401 electrical machines-i
ee6401 electrical machines-i

UNIT 17 MOTOR CONTROL
UNIT 17 MOTOR CONTROL

... if the motor should stall. The motor current depends upon the supply voltage. Naturally then, a given size of motor starter could handle a higher horsepower motor at 460 V than at 230 V. NEMA sizes and horsepower ratings are given in Table 17-1. Motor starters are available with two poles or three p ...
S1000 Specific characteristics of this series:
S1000 Specific characteristics of this series:

Application Note No. 7038
Application Note No. 7038

... If on loadside of the final Branch Circuit overcurrent device and MMP is marked “Suitable as Motor Disconnect” Must be part of a listed combination, typically from same manufacturer Cost increases as interrupting rating increases Limits application to solidly grounded wye systems only, not permitted ...
PicoTurbine Deluxe Windmill Plans
PicoTurbine Deluxe Windmill Plans

Electrical troubleshooting Yerf Dog LAST UPDATED: 10/8/2011 See
Electrical troubleshooting Yerf Dog LAST UPDATED: 10/8/2011 See

AH5795  SINGLE PHASE HALL EFFECT LATCH SMART FAN MOTOR CONTROLLER
AH5795 SINGLE PHASE HALL EFFECT LATCH SMART FAN MOTOR CONTROLLER

... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
Siemens Standard Drives Application Handbook
Siemens Standard Drives Application Handbook

submersible pump with hazardous location motor end
submersible pump with hazardous location motor end

... For use with product built with USEM motor. ORDERING REPLACEMENT PARTS: Product improvements are made from time to time. The latest part design will be furnished as long as it is interchangeable with the old part.When ordering replacement parts, always furnish the following information: (1) pump ser ...
Fig. 2.12: Simplified equivalent circuit of a transformer at full
Fig. 2.12: Simplified equivalent circuit of a transformer at full

Motor Vehicle Level 3
Motor Vehicle Level 3

... •Voltage signal produced is sent to the input of the ECU for analysation. •The ECU will covert this Analogue signal to Digital signal which the ECU can read. •The ECU will now react (alter the brake pressure depending on this voltage signal. ...
Superconductors - Maritime Symposium Rotterdam
Superconductors - Maritime Symposium Rotterdam

... disappears when the material is cooled below a certain critical temperature. Metals conducting electricity at room temperature always have a resistance that results in a loss of power which is converted to heat. There are also insulators like plastic and rubber that conduct no electricity or very li ...
KS2518741883
KS2518741883

... practical device. In addition, electrolytic capacitors are not suitable for high-temperature applications, such as in HEVs. Overall, these disadvantages of the electrolytic capacitor affect the reliability of the converter. For the secondary input power source, a boost converter that consists of a b ...
AH5792  SINGLE PHASE HALL EFFECT LATCH SMART FAN MOTOR CONTROLLER
AH5792 SINGLE PHASE HALL EFFECT LATCH SMART FAN MOTOR CONTROLLER

... diode D1 between power supply and Vdd terminal. In such case of using reverse power protection diode D1 because of there is no way to return current to power supply, please take necessary measures like below. - Connect Dz (Zener diode) between Vdd and Vss terminal, not to exceed the absolute maximum ...
Lesson: 23
Lesson: 23

... transmission lines. The cross sectional area of the conductor of the lines accordingly should be large. Hence cost involved in transmitting a given amount of power rises many folds. Not only that, the transmission lines has their own resistances. This huge amount of current will cause tremendous amo ...
Design Principles of Integrated Magnetic Bearings - ETH E
Design Principles of Integrated Magnetic Bearings - ETH E

HV-Maxx Instructions.pm
HV-Maxx Instructions.pm

Document
Document

...  Manufacturers always specify the voltage rating of the primary and secondary windings.  Under no circumstances should the primary voltage rating be exceeded.  In many cases, the rated primary and secondary voltages are printed on the transformer.  Regardless of how the secondary voltage is spec ...
B. Tech. (Electrical Engineering)
B. Tech. (Electrical Engineering)

< 1 ... 38 39 40 41 42 43 44 45 46 ... 226 >

Induction motor



An induction or asynchronous motor is an AC electric motor in which the electric current in the rotor needed to produce torque is obtained by electromagnetic induction from the magnetic field of the stator winding. An induction motor therefore does not require mechanical commutation, separate-excitation or self-excitation for all or part of the energy transferred from stator to rotor, as in universal, DC and large synchronous motors. An induction motor's rotor can be either wound type or squirrel-cage type.Three-phase squirrel-cage induction motors are widely used in industrial drives because they are rugged, reliable and economical. Single-phase induction motors are used extensively for smaller loads, such as household appliances like fans. Although traditionally used in fixed-speed service, induction motors are increasingly being used with variable-frequency drives (VFDs) in variable-speed service. VFDs offer especially important energy savings opportunities for existing and prospective induction motors in variable-torque centrifugal fan, pump and compressor load applications. Squirrel cage induction motors are very widely used in both fixed-speed and variable-frequency drive (VFD) applications. Variable voltage and variable frequency drives are also used in variable-speed service.