• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Radiologic Findings in Multiple Sclerosis
Radiologic Findings in Multiple Sclerosis

... Received cyclophosphamide therapy and plasmapheresis within the past year MRI scans taken in March and in September ...
Three-Dimensional Radiation Treatment Planning
Three-Dimensional Radiation Treatment Planning

... At the University of Michigan Thornton et al. [31] demonstrated a significant saving of normal brain tissue with conformal nonaxial techniques in 50 patients. When compared with conventional parallel opposed fields, uniform target volume coverage could be maintained while saving 30% of brain tissue ...
Case 1
Case 1

... High incidence of morbidity in survivors from short gut syndrome and dependence on TPN leading to cirrhosis May present at any age, but 60% present by one month of age Present with bilious vomiting :Diagnose with upper GI :Malrotation Abnormally positioned duodenojejunal junction Right of spine Infe ...
X-ray - Pharos University in Alexandria
X-ray - Pharos University in Alexandria

... images of the body. Sonography uses highfrequency sound waves to create crosssectional still or real-time (motion) images of the body. ...
Image-Guided Interventions: Applications, Modalities, and Future
Image-Guided Interventions: Applications, Modalities, and Future

... Michael Vannier, M.D. Professor of Radiology, University of Iowa Robot-Assisted and 3D Ultrasound-Guided Prostate Brachytherapy Aaron Fenster, Ph.D. Director of the Imaging Research Department, Robarts Research Institute Professor of Medical Biophysics, University of Western Ontario Image-Guided Int ...
A Summary of Radiation Dose Guidelines and Limits Applicable to
A Summary of Radiation Dose Guidelines and Limits Applicable to

... Radiation dose guidelines apply to the dose from all radionuclide procedures and all diagnostic radiology (x-ray) procedures related to the research study, together with doses from other research studies in which the subject may be participating or has participated in during the year. The above dose ...
X-ray Technician Refresher Training
X-ray Technician Refresher Training

... – Digital resulted in good images without changing factors, even if patient dose was higher, so factors were not optimized to lower dose. – Also, techniques were used to reduce signal noise that resulted in increased dose. ...
Optical microscopy
Optical microscopy

... of the heart is imaged more than once while an ECG trace is recorded. The ECG is then used to correlate the CT data with their corresponding phases of cardiac contraction. Once this correlation is complete, all data that were recorded while the heart was in motion (systole) can be ignored and images ...
Precise ex-vivo histological validation of heightened
Precise ex-vivo histological validation of heightened

... Radiology and Biophysics, Medical College of Wisconsin INTRODUCTION It has been generally accepted that the edema surrounding brain tumors, which is apparent as abnormally high signal on FLAIR (fluid attenuated inversion recovery) images, is likely comprised of invading tumor cells. Consequently, ra ...
Refresher Training for X-Ray Equipment Operators
Refresher Training for X-Ray Equipment Operators

... – Digital resulted in good images without changing factors, even if patient dose was higher, so factors were not optimized to lower dose. – Also, techniques were used to reduce signal noise that resulted in increased dose. ...
Slide 1
Slide 1

... magnification. To keep magnification small (close to m=1) requires the image receptor to be as close as possible to the patient and the focus patient distance to be large. Typical conditions are: a  1mm d1  1 m ...
ACR–AAPM Technical Standard for Medical Physics Performance
ACR–AAPM Technical Standard for Medical Physics Performance

... rapidly gathered to identify the position of a target in space. These implementations often use x-ray generators that are in the diagnostic energy range to obtain better image quality as compared to traditional treatment portal images. In addition, some imaging systems mount the x-ray sources and el ...
Radiation Protection Of Medical Staff
Radiation Protection Of Medical Staff

... can range from very short fluoroscopy times (<0.5 min for a typical orthopaedic procedure) to very long fluoroscopy times, such as 60–90 min for an aortic aneurysm treatment. The main issue is that the non-radiologist specialists and nurses involved in these procedures are often outside the umbrella o ...
Diagnostic Imaging
Diagnostic Imaging

... a large tube that looks like a large doughnut standing on its side, and the person lies on the table in the center. – The X-ray tube rotates around the body. – The table slowly moves through the inside of the machine. – Each rotation yields several images of thin slices of the body. ...
X-ray generation, interaction and detection
X-ray generation, interaction and detection

... • Provide wide range of Dose/IQ selections to operator • Provide Dose Feedbacks to clinician for awareness and decision making. • Automate the process as much as ...
Breast Plan Simulation Directive
Breast Plan Simulation Directive

... Electronically signed by controlled access password ...
Establishing national diagnostic reference levels for digital
Establishing national diagnostic reference levels for digital

... [4] NHS Breast Screening Programme Publication Number 54, UK, February 2003 [5] Ionising Radiation (Medical Exposure) Regulations, (SI 2000 No 1059), UK:HMSO, 2000 [6] Dosimetry Working Party of the Institute of Physical Sciences in Medicine. National protocol for patient dose measurements in diagno ...
A case reportof the cervix
A case reportof the cervix

... Rationale: brachytherapy is administered in the treatment of patients with locally advanced cervical cancer following chemoradiotherapy. Lack of local anatomy evaluation prior to this procedure might lead to the selection of an inappropriate brachytherapy applicator, increasing the risk of side effe ...
Date approved or revised
Date approved or revised

... L. Exposure Indicator Determination M. Gross Exposure Error (e.g., mottle, light or dark, low contrast) ...
Refresher Training for X-Ray Equipment Operators
Refresher Training for X-Ray Equipment Operators

... – Digital resulted in good images without changing factors, even if patient dose was higher, so factors were not optimized to lower dose. – Also, techniques were used to reduce signal noise that resulted in increased dose. ...
a time of opportunity for medical physics
a time of opportunity for medical physics

... physicists are becoming increasingly responsible for designing, deploying and monitoring the treatments using sophisticated instrumentation and computer-based platforms. As new imaging technologies, and improvements in existing technologies, are introduced into radiology and radiation oncology, phy ...
Medical radiation exposure and accidents. Dosimetry and radiation
Medical radiation exposure and accidents. Dosimetry and radiation

... rules to avoid them Accidents and risks from MRE have been described before. Several millions of medical diagnostic and therapeutic radiation procedures are performed annually worldwide, so MRA may be expected, some of them late to recognize. Most of MRA are easy to manage, do not usually causes cas ...
CMPI Exam Format - College of Medical Physics, India
CMPI Exam Format - College of Medical Physics, India

... 6.2 The candidates desiring to take only the written examination will have to pay Rs 2000 /- only, however such candidates will have to pay Rs 3000 /- as oral examination fee while appearing for the oral examination. Candidates can pay the fees in total or in parts as given above. 6.3 Reappearance i ...
EXAM: MYOVIEW STRESS TEST (ADENOSINE or LEXISCAN
EXAM: MYOVIEW STRESS TEST (ADENOSINE or LEXISCAN

... chemical. A Nuclear Medicine Technologist will inject another dose of radioisotope. After the patient completes the chemical stress, the patient will need to allow the radioisotope to circulate a minimum of 45 minutes. The patient will then be imaged for about 15-20 minutes. The study is completed a ...
Generation of Hard Quasimonochromatic Radiation Using a Table
Generation of Hard Quasimonochromatic Radiation Using a Table

... organic materials Concern Radiation-induced damage: photon energy deposited per unit mass (dose) can cause observable changes in structure ...
< 1 ... 53 54 55 56 57 58 59 60 61 ... 78 >

Radiosurgery

Radiosurgery is surgery using radiation, that is, the destruction of precisely selected areas of tissue using ionizing radiation rather than excision with a blade. Like other forms of radiation therapy, it is usually used to treat cancer. Radiosurgery was originally defined by the Swedish neurosurgeon Lars Leksell as “a single high dose fraction of radiation, stereotactically directed to an intracranial region of interest”. In stereotactic radiosurgery (SRS), the word stereotactic refers to a three-dimensional coordinate system that enables accurate correlation of a virtual target seen in the patient's diagnostic images with the actual target position in the patient anatomy.Technological improvements in medical imaging and computing have led to increased clinical adoption of stereotactic radiosurgery and have broadened its scope in recent years. Notwithstanding these improvements, the localization accuracy and precision that are implicit in the word “stereotactic” remain of utmost importance for radiosurgical interventions today. Stereotactic accuracy and precision are significantly increased by using a device known as the N-localizer that was invented by the American physician and computer scientist Russell Brown and that has achieved widespread clinical use in several stereotactic surgical and radiosurgical systems.Recently, the original concept of radiosurgery has been expanded to include treatments comprising up to five fractions, and stereotactic radiosurgery has been redefined as a distinct neurosurgical discipline that utilizes externally generated ionizing radiation to inactivate or eradicate defined targets in the head or spine without the need for a surgical incision. Irrespective of the similarities between the concepts of stereotactic radiosurgery and fractionated radiotherapy, and although both treatment modalities are reported to have identical outcomes for certain indications, the intent of both approaches is fundamentally different. The aim of stereotactic radiosurgery is to destroy target tissue while preserving adjacent normal tissue, where fractionated radiotherapy relies on a different sensitivity of the target and the surrounding normal tissue to the total accumulated radiation dose. Historically, the field of fractionated radiotherapy evolved from the original concept of stereotactic radiosurgery following discovery of the principles of radiobiology: repair, reassortment, repopulation, and reoxygenation. Today, both treatment techniques are complementary as tumors that may be resistant to fractionated radiotherapy may respond well to radiosurgery and tumors that are too large or too close to critical organs for safe radiosurgery may be suitable candidates for fractionated radiotherapy.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report