• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Ideal Radionuclide
Ideal Radionuclide

... • localises only in organ of interest • t1/2 of elimination from body similar to duration of test ...
HIPAA Transaction Standard Impact
HIPAA Transaction Standard Impact

... reducing costs does not improve quality – 69% reduction of redundant lab tests (Bates, 1999) ...
Medical Imaging Primer with a Focus on X
Medical Imaging Primer with a Focus on X

... acquisition is used to reconstruct the slice of the patient imaged. This process is then repeated for different areas of the patient, thus resulting in a 2D stack of axial images of the patient. Advanced data acquisition techniques and computer processing can be employed to produce a variety of imag ...
Clinical commissioning and use of the Novalis Tx linear accelerator
Clinical commissioning and use of the Novalis Tx linear accelerator

... (IR) cameras, dual X-ray imagers, and a robotic couch. The IR cameras guide the initial patient setup by monitoring 4–5 external IR markers attached to the patient surface. Two kilovoltage (kV) planar X-ray images are acquired and coregistered with the 3D CT images, using a fully automatic intensity ...
MAGNETIC RESONANCE IMAGING
MAGNETIC RESONANCE IMAGING

... to visualize detailed structures within the human body. MRI provides superior contrast between the different soft tissues of the body. Today MRI is the gold standard in multiple medical specialties. Magnetic resonance imaging tests use special equipment that utilizes a constant and powerful magnetic ...
Control of patient exposure with true anatomy
Control of patient exposure with true anatomy

... Maintaining quality and consistency In today’s digital x-ray world, modern systems use automatic image processing, so the ratio between detector exposure and image brightness is not always clear. The old visual control function for excessive dosage has been removed, so over/under exposures may go un ...
imagination at work
imagination at work

... Lowering dose while delivering high image quality and more efficient imaging workflow. A proven leader in dose-reduction technologies, GE continues to develop important dose-optimization features available across all platforms. The Brivo CT385 offers many tools to help manage dose, with clinically d ...
Investigation of Electrostatic Charging Phenomenon in Multiphase
Investigation of Electrostatic Charging Phenomenon in Multiphase

... based tomography systems are the most prominent due to their low construction cost, high speed, and safety. The development of electrical tomography has been mainly focused on permittivity, conductivity, or permeability imaging. Successful implementation of tomography systems depends on the sensor c ...
Slide 1
Slide 1

... If you have recently viewed medical records, these records will appear in a list If no records have been recently viewed, no records will be displayed ...
physics lecture
physics lecture

... - enhances natural tissue contrast and does not produce scatter radiation; more radiation for the patient (bad) - most common reaction in lowenergy photons 3) Compton Scattering - contribute almost all the scatter radiation in diagnostic radiology incident photon strike a free OUTER shell electron; ...
Advanced Imaging Techniques in Multiple Sclerosis
Advanced Imaging Techniques in Multiple Sclerosis

... Magnetization transfer imaging (MTI) is increasingly used to characterize the evolution of MS lesions and normal appearing brain tissue. Evidence suggests that the dynamics of magnetization transfer changes correlate with the extent of demyelination and remyelination. Magnetic resonance spectroscopy ...
Innovation Focus Hybrid Imaging
Innovation Focus Hybrid Imaging

... procedure to reconstruct images taken by sections with the aim to transform them in first several two dimensional pictures, which when combined can provide three-dimensional representation. Adaptation of this technology led to the development of CT, SPECT, PET and MRI scanners. ...
New Imaging Concepts in Central Nervous System Neoplasms
New Imaging Concepts in Central Nervous System Neoplasms

... characterise using conventional and advanced sequences  DWI and MRS are no good predictors for tumor grading in glial tumors  Still a lot of research has to be done to look for new radiological biomarkers in other common brain tumors like glial tumors ...
Commissioning of linear accelerators: From acceptance to first
Commissioning of linear accelerators: From acceptance to first

... End-to-end testing of image-based localization and the entire process, from simulation to dose delivery must be performed Independent verification of the beam model data, absolute calibration, and end-to-end testing is helpful ...
ScImage and NextGen Healthcare expand partnership Offers
ScImage and NextGen Healthcare expand partnership Offers

... offers a broad, multi-specialty portfolio of specialty specific clinical content across more than 25 specialties which encompasses traditional cardiology and radiology PACS, and expands to additional sub-specialties such as obstetrics, orthopedics, mammography and dental. ScImage’s flexible PICOM365 ...
Quality assurance for image-guided radiation therapy
Quality assurance for image-guided radiation therapy

... image-guided radiotherapy. The first integrated clinical system combining a linac and an in-treatment-room CT unit was developed by Uematsu et al. in Japan.26 The original system was primarily designed for noninvasive, frameless, fractionated stereotactic treatments of brain and lung cancers. The di ...
View Event Brochure - Emory Core Facilities
View Event Brochure - Emory Core Facilities

... technologies that bridge the in vitro and ex vivo molecular analysis and non-invasive high resolution clinical diagnostic imaging. This brief overview is an entry-point introduction on MR physics, signal sources, contrast mechanisms, instrumentation/scanners and general MRI parameters and techniques ...
2008 January DAI News - Carl E Ravin Advanced Imaging
2008 January DAI News - Carl E Ravin Advanced Imaging

... chest correlation and stereo imaging. The system is capable of acquiring multi-projection images from any verticalor horizontal-oblique orientation within a ±20 degree range. A clinical trial has commenced with over 45 human subjects with confirmed subtle lung nodules already imaged. We have also in ...
Bicycle Stress Echocardiography Protocol
Bicycle Stress Echocardiography Protocol

...  Have patient pedal until green light comes on.  Start ECG timer and bike timer at the same time.  Do a blood pressure every 2 minutes and multiply the systolic blood pressure number by the heart rate at each stage for the RPP (Rate Pressure Product).  A minimum RPP of 20,000 is required to make ...
Neuroradiology Articles From Around the World
Neuroradiology Articles From Around the World

... predictor for herniation shrinkage. Seventy-two patients with 80 disc herniations (detected on initial CT) who presented with lower back pain or sciatica of more than 3 months entered the study. Gadolinium-enhanced MRI with a delay of 30 seconds was performed at enrollment, then every 6 months for 1 ...
Recent Advances in Brain MR Imaging
Recent Advances in Brain MR Imaging

... Departments of Radiology, Oncology and Biomedical Engineering Emory University School of Medicine and Department of Radiology Duke University Medical Center ...
RAD 354 Chapt. 28 The Digital Image
RAD 354 Chapt. 28 The Digital Image

... gray = BLACK AND WHITE! ...
Interventional Radiology
Interventional Radiology

... for better listening so as not to miss important points; less note taking. Easier to review along with the Core Curriculum manual, thank you. ...
Nuclear Medicine
Nuclear Medicine

... In nuclear medicine studies, the radiopharmaceutical given to the patient makes them, and the organ system or body part being studied, radioactive for a short time. This ionising radiation (usually a gamma ray) is emitted or released from the body, and can be detected and measured using a nuclear me ...
Multi-Level Codes deliver dramatic improvements in ultrasound
Multi-Level Codes deliver dramatic improvements in ultrasound

... transmission and retrieval strategies. When applied to ultrasound, Code technology forms and transmits digitally encoded pulse sequences – pulse sequences which have been encoded with unique signatures that stay with them throughout the transmit and receive process. When these specially encoded sign ...
< 1 ... 123 124 125 126 127 128 129 130 131 ... 173 >

Image-guided radiation therapy

Image-guided radiation therapy (IGRT) is the process of frequent two and three-dimensional imaging, during a course of radiation treatment, used to direct radiation therapy utilizing the imaging coordinates of the actual radiation treatment plan. The patient is localized in the treatment room in the same position as planned from the reference imaging dataset. An example of IGRT would include localization of a cone beam computed tomography (CBCT) dataset with the planning computed tomography (CT) dataset from planning. IGRT would also include matching planar kilovoltage (kV) radiographs or megavoltage (MV) images with digital reconstructed radiographs (DRRs) from the planning CT. These two methods comprise the bulk of IGRT strategies currently employed circa 2013.This process is distinct from the use of imaging to delineate targets and organs in the planning process of radiation therapy. However, there is clearly a connection between the imaging processes as IGRT relies directly on the imaging modalities from planning as the reference coordinates for localizing the patient. The variety of medical imaging technologies used in planning includes x-ray computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET) among others. The precision of IGRT is significantly improved when N-localizer technology is used in conjunction with these medical imaging technologies. Through advancements in imaging technology, combined with a further understanding of human biology at the molecular level, the impact of IGRT on radiotherapy treatment continues to evolve.