• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CdTe and CdZnTe detectors in nuclear medicine
CdTe and CdZnTe detectors in nuclear medicine

... distance both due to geometrical considerations and to other spatial super-impositions of various biological sources that have physiologically, including circulating blood, or pathologically uptake the tracer. Ampli"cation of the contrast is achieved by the use of the computed tomography principle ( ...
A New Approach for Motion Correction in SPECT - CEUR
A New Approach for Motion Correction in SPECT - CEUR

... artefacts. These motion artefacts may significantly affect the diagnostic accuracy [2, 3, 4]. Different methods have been proposed for the correction of motion in SPECT studies. These methods may be divided into three categories. The first two approaches do produce motion corrected projections and t ...
Perfusion magnetic resonance imaging with continuous arterial spin
Perfusion magnetic resonance imaging with continuous arterial spin

... resonance imaging (MRI). One class of techniques utilizes electromagnetically labeled arterial blood water as a noninvasive diffusible tracer for blood flow measurements. The electromagnetically labeled tracer has a decay rate of T1, which is sufficiently long to allow perfusion of the tissue and mi ...
Module 4: Screening and Diagnosis
Module 4: Screening and Diagnosis

... alone in detecting carcinoma or carcinoma in situ. They did not find an excessive number of false positives, as has been raised by other researchers. ...
Provisional Monthly Diagnostic Imaging Dataset
Provisional Monthly Diagnostic Imaging Dataset

... Plain Radiography (X-ray) made up the majority of all tests performed during the year, with over 21 million X-rays being reported. The next most common procedures were Ultrasound and CT-scans, with about 7.7 and 3.3 million tests reported respectively. Medical Photography procedures accounted for th ...
3-D Image Postprocessing Educational Framework
3-D Image Postprocessing Educational Framework

... postprocessing techniques, such as volume rendering and multiplanar reformations, allow realtime viewing of exam data in any plane with the ability to screen-capture the images for permanent digital archive. A variety of measurements also may be extracted from the volume data. The consistency and ac ...
Guidelines On Teleradiology In Malaysia
Guidelines On Teleradiology In Malaysia

... reduction in clinically diagnostic image quality. The compression can be divided into two broad categories i.e. reversible/lossless and irreversible/lossy. Although lossless compression has been advocated, recent lossy compression using wavelets may be acceptable. However caution needs to be exercis ...
Examples-for-Preventice-Meeting
Examples-for-Preventice-Meeting

... Oracle . CX Strategy & Design Workshop . DesigningCX.com ...
Abdominal Pain in a Pregnant Patient
Abdominal Pain in a Pregnant Patient

... Delayed diagnosis may lead to perforation Surgery may lead to premature delivery and fetal loss Ultrasound is the initial imaging modality of choice MRI is performed if the ultrasound is inconclusive Key findings include an enlarged fluid-filled appendix and periappendiceal inflammation ...
Single Photon Emission Computed Tomography
Single Photon Emission Computed Tomography

... the patient over 180° or 360°. Although 180° data collection is commonly used (particularly in cardiac studies), 360° data acquisition is preferred by some investigators, because it minimizes the effects of attenuation and variation of resolution with depth. In 180° acquisition using a dual-head cam ...
Dynamic Imaging of Lymphatic Vessels and Lymph
Dynamic Imaging of Lymphatic Vessels and Lymph

... wound infections.3,5 In animal models, lymphography has been predominantly limited to the use of Evans blue dye7 and fluorescently labeled dextrans.8 Lymphoscintigraphy, which is traditionally used to localize sentinel lymph nodes, has low temporal and spatial resolution and fails to adequately demo ...
Optical Coherence Tomography: Newer Techniques, Newer Machines
Optical Coherence Tomography: Newer Techniques, Newer Machines

... Since 1991, when optical coherence tomography (OCT) was first introduced as a tool for investigation in ophthalmology,1 OCT has become the mainstay in retinal imaging and, in some situations, has supplanted fundus fluoresce in angiography which is regarded, even today, as the gold standard for investi ...
Applications for OCT Enhanced Depth Imaging
Applications for OCT Enhanced Depth Imaging

... Technology in the early 1990s,1 this imaging modality has allowed ophthalmologists to see the eye from a different perspective. The cross-sectional images it provides of the retina are analogous to histology slices, but in living tissue. These images, sometimes likened to a “virtual biopsy,” are obt ...
Shielding Of Medical Facilities. Shielding Design
Shielding Of Medical Facilities. Shielding Design

... • The placement of the door must be carefully considered to avoid the expense with installing one with substantial lead shielding. • It is a good idea to have the hot bathroom, reserved for PET patients, within the immediate imaging area, so that they do not alter the background counts of other dete ...
DECT: GU Applications - SCBT-MR
DECT: GU Applications - SCBT-MR

... • Acquire attenuation values of same structures at two different energy levels • Measure change in attenuation of voxels between two energies • Differentiate and quantify materials ...
Attenuation
Attenuation

... • Broad term first used medically in 1970s in computed tomography (CT). • Digital imaging is defined as any image acquisition process that produces an electronic image that can be viewed and manipulated on a computer. • In radiology, images can be sent via computer networks to a variety of locations ...
Enhancement of Focal Liver Lesions at Gadoxetic Acid–enhanced
Enhancement of Focal Liver Lesions at Gadoxetic Acid–enhanced

... MATERIALS AND METHODS: Study was supported by local ethics committee; all patients gave written informed consent. In 19 men and 14 women recruited in three clinical studies, histopathologic correlation and CT scans of 41 focal lesions (13 primary malignant lesions, 21 metastases, three adenomas, thr ...
NCAT Coding Guide for Radiotherapy (External Beam
NCAT Coding Guide for Radiotherapy (External Beam

... Single electron (e.g. breast boost / soft tissue mass etc) 3 or 4 field palliative Any other simple technique that does not require serial imaging. ...
Tomosynthesis used for a diagnostic mammogram identifies a true
Tomosynthesis used for a diagnostic mammogram identifies a true

... New York, NY.   ...
Radiologists` Preferences for Digital Mammographic
Radiologists` Preferences for Digital Mammographic

... Digital mammograms can be printed on film or displayed on a monitor. Typically, laser-printed films can display 4,000 ⫻ 5,000 pixels at 12-bit gray scale. Although most radiologists are currently more comfortable with the use of these printed images, the disadvantages of hard-copy image display at d ...
Comparison of Patient Localization Accuracy Between Stereotactic
Comparison of Patient Localization Accuracy Between Stereotactic

... In clinical situation, ETX and CBCT images are majorly applied to the patient localization before treatment. These are useful to be close to origin of the coordinate of PTV. In addition, it is possible to monitor the intra-fraction organ motion if we use them during treatment. The advantages of ETX ...
Magnetic Resonance Angiography Techniques
Magnetic Resonance Angiography Techniques

...  Resonance Angiography Limitations of Contrast-Enhanced Magnetic Resonance Angiography ■■ Postprocessing and Display Maximum Intensity Projection Algorithm Limitations of Maximum Intensity Projection Reformatting ■■ Summary Magnetic resonance (MR) imaging is well suited as a modality for evaluating ...
Ultrasound vs MRI in Diagnosis of Fetal and
Ultrasound vs MRI in Diagnosis of Fetal and

... Ultrasound is the screening modality of choice for the fetal imaging. However, there are circumstances in which an alternative imaging technique is needed for additional information regarding fetal anatomy and pathology as well as different maternal conditions. Magnetic resonance imaging (MRI) is be ...
DICOM Digital Mammography Subgroup
DICOM Digital Mammography Subgroup

... concerns about the relationship between Digital Mammography X-ray Image For Processing, Mammography CAD SR, and Digital Mammography X-ray Image For Presentation instances, given that most mammography CAD devices perform CAD on For Processing images, most softcopy workstations display only For Presen ...
Evaluation of Diagnostic Reference Levels for CT scan in Isfahan
Evaluation of Diagnostic Reference Levels for CT scan in Isfahan

... © 2014 Global Journal of Medicine Researches and Studies. All rights reserved for Academic Journals Center. ...
< 1 ... 58 59 60 61 62 63 64 65 66 ... 159 >

Medical imaging



Medical imaging is the technique and process of creating visual representations of the interior of a body for clinical analysis and medical intervention. Medical imaging seeks to reveal internal structures hidden by the skin and bones, as well as to diagnose and treat disease. Medical imaging also establishes a database of normal anatomy and physiology to make it possible to identify abnormalities. Although imaging of removed organs and tissues can be performed for medical reasons, such procedures are usually considered part of pathology instead of medical imaging.As a discipline and in its widest sense, it is part of biological imaging and incorporates radiology which uses the imaging technologies of X-ray radiography, magnetic resonance imaging, medical ultrasonography or ultrasound, endoscopy, elastography, tactile imaging, thermography, medical photography and nuclear medicine functional imaging techniques as positron emission tomography.Measurement and recording techniques which are not primarily designed to produce images, such as electroencephalography (EEG), magnetoencephalography (MEG), electrocardiography (ECG), and others represent other technologies which produce data susceptible to representation as a parameter graph vs. time or maps which contain information about the measurement locations. In a limited comparison these technologies can be considered as forms of medical imaging in another discipline.Up until 2010, 5 billion medical imaging studies had been conducted worldwide. Radiation exposure from medical imaging in 2006 made up about 50% of total ionizing radiation exposure in the United States.In the clinical context, ""invisible light"" medical imaging is generally equated to radiology or ""clinical imaging"" and the medical practitioner responsible for interpreting (and sometimes acquiring) the images is a radiologist. ""Visible light"" medical imaging involves digital video or still pictures that can be seen without special equipment. Dermatology and wound care are two modalities that use visible light imagery. Diagnostic radiography designates the technical aspects of medical imaging and in particular the acquisition of medical images. The radiographer or radiologic technologist is usually responsible for acquiring medical images of diagnostic quality, although some radiological interventions are performed by radiologists.As a field of scientific investigation, medical imaging constitutes a sub-discipline of biomedical engineering, medical physics or medicine depending on the context: Research and development in the area of instrumentation, image acquisition (e.g. radiography), modeling and quantification are usually the preserve of biomedical engineering, medical physics, and computer science; Research into the application and interpretation of medical images is usually the preserve of radiology and the medical sub-discipline relevant to medical condition or area of medical science (neuroscience, cardiology, psychiatry, psychology, etc.) under investigation. Many of the techniques developed for medical imaging also have scientific and industrial applications.Medical imaging is often perceived to designate the set of techniques that noninvasively produce images of the internal aspect of the body. In this restricted sense, medical imaging can be seen as the solution of mathematical inverse problems. This means that cause (the properties of living tissue) is inferred from effect (the observed signal). In the case of medical ultrasonography, the probe consists of ultrasonic pressure waves and echoes that go inside the tissue to show the internal structure. In the case of projectional radiography, the probe uses X-ray radiation, which is absorbed at different rates by different tissue types such as bone, muscle and fat.The term noninvasive is used to denote a procedure where no instrument is introduced into a patient's body which is the case for most imaging techniques used.
  • studyres.com © 2025