• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Image reconstruction
Image reconstruction

... a remarkable paper, ‘Reconstruction of densities from their projections, with applications in radiological physics’, Cormack (1973) compared different approaches to transaxial section reconstruction and related how ‘it has recently come to the author’s attention that the problem of determining a fun ...
Searching for relevant patents using TRIZ and Patent Citation Analysis
Searching for relevant patents using TRIZ and Patent Citation Analysis

... Magnetic Resonance Imaging (MRI) is extensively used as an image analysis tool for diagnosis of the human body. Today MRI is widely used in defining the soft tissue anatomy, characterization or dynamic study in 4D. There are challenges in Magnetic Resonance (MR) image acquisition and analysis for pa ...
Learning objectives
Learning objectives

...  Increased radio-sensitivity, small size, longevity. ...
Phantom Patient for Stereotactic End-to
Phantom Patient for Stereotactic End-to

... Stereotactic Radiosurgery (SRS) necessitates a high degree of accuracy in target localization and dose delivery. Small errors can result in significant under treatment of portions of the tumor volume and overdose of nearby normal tissues. The CIRS Stereotactic End-toEnd Verification Phantom “STEEV” ...
Imaging of multiple myeloma: Current concepts Thorsten Derlin
Imaging of multiple myeloma: Current concepts Thorsten Derlin

... of soft tissue manifestations and the ability to differentiate between physiological and myeloma-infiltrated bone marrow[6,33-35]. The involvement of the bone marrow is classified in three different patterns[9,36-38]: focal lesions, homogenous diffuse bone marrow infiltration and mixed “salt-and-pep ...
Imaging of the liver
Imaging of the liver

... • uses the magnetic properties of the hydrogen nucleus present in water molecules (thus in all body tissues) • nuclei behave like compass needles that are partially aligned by a strong magnetic field in the scanner • the nuclei can be rotated using radio waves • subsequently oscillate in the magneti ...
Accuracy of linear measurement in Galileos cone beam CT under
Accuracy of linear measurement in Galileos cone beam CT under

... Computed tomography which is a 3D imaging modality had long been in use in medical radiology before its use in dental implant imaging. The first modern computed tomography (CT) scanner developed by Godfrey Hounsfield in 1967 was first introduced in clinics in 1971. The basic concept of CT includes m ...
DIAGNOSTIC PERFORMANCE OF LOW-DOSE ATTENUATION-CORRECTED REST/STRESS Tc-99m TETROFOSMIN
DIAGNOSTIC PERFORMANCE OF LOW-DOSE ATTENUATION-CORRECTED REST/STRESS Tc-99m TETROFOSMIN

... DNM 530c SPECT to conventional SPECT, some patients with breast attenuation noted in the anterior wall on conventional SPECT had no loss of counts on D530c SPECT. Instead some of these patients had a mild count loss in the inferior wall.1 Attenuation correction may be performed on the DNM 530c by re ...
Quantification of SPECT myocardial perfusion imaging. Acampa W
Quantification of SPECT myocardial perfusion imaging. Acampa W

... SPECT imaging provides important prognostic information in patients with either known or suspected coronary artery disease. An important significance has been given to the evaluation of the extent of myocardial perfusion defects. For example, in patients with known coronary artery disease and LV dys ...
NDAC TITLE 114 ND MEDICAL IMAGING and RADIATION
NDAC TITLE 114 ND MEDICAL IMAGING and RADIATION

... licensed practitioner, who uses radiofrequencies transmission within a high strength magnetic field on humans for diagnostic, therapeutic or research purposes. 25. “Mammography technologist” means an individual, other than a licensed practitioner, that is responsible for administration of ionizing r ...
Mammography
Mammography

... • You’ll need to see your doctor or nurse for a clinical breast exam. All women in their 20s and 30s should have a breast exam as part of their regular health checkups at least every 3 years. • After the age of 40, have a breast exam ...
Complications and post-transplant follow-up - 公務出國報告
Complications and post-transplant follow-up - 公務出國報告

... did not fit the Milan criteria. One patient had 5 tumors less than 3-cm and the largest tumor was treated by 1 session of RFA. One patient had 4 tumors less than 3-cm, and 2 of the 4 tumors were treated by 1 session of RFA. Another patient had 2 tumors, and 1 session of RFA was performed on 1 tumor, ...
Total Solutions
Total Solutions

... Alignment Adds Safety ...
Institutionen för medicin och hälsa Department of Medical and Health Sciences
Institutionen för medicin och hälsa Department of Medical and Health Sciences

... Moreover, in theory a single quantitative measurement makes it possible to postsynthesize an infinite number of contrast-weighted images that with the conventional technique each need a separate scan to be acquired. The approach of quantitative MRI (qMRI) has been discussed since the end of the 1990 ...
Time-resolved projection angiography after bolus injection of
Time-resolved projection angiography after bolus injection of

... months due to the development of gradient systems for fast imaging. Three-dimensional acquisition schemes based on gradient echo techniques with short echo times on the order of 2-4 ms and short repetition times of 4-7 ms have been used to acquire three-dimensional datasets within one breathhold (1- ...
Professional capabilities for medical radiation practice
Professional capabilities for medical radiation practice

... Level of capability when entering or re-entering the profession in Australia ................................................. 2 Domain 1: Professional and ethical conduct ................................................................................................. 3 Domain 2: Communication and ...
MR 450W: Abdominal Imaging PDF 2MB
MR 450W: Abdominal Imaging PDF 2MB

... The large FOV of 50 cm covered by the Anterior Array coil (AA), combined with the Posterior Array coil (PA) makes it possible to scan the liver and the small bowel in the same acquisition. Cube (a) and LAVA Flex (b) provide high resolution images (3D) for the evaluation of oncologic and inflammatory ...
Magnetic resonance imaging in canine spontaneous - E
Magnetic resonance imaging in canine spontaneous - E

... ISBN 952-91-2208-X (nid.) ISBN 952-91-2209-8 (PDF version) Helsingin yliopiston verkkojulkaisut HELSINKI 2000 ...
X-Ray Equipment PROCEDURE MANUAL - Dartmouth
X-Ray Equipment PROCEDURE MANUAL - Dartmouth

... PBL (positive beam limitation): Place a cassette of the most commonly used size in the Bucky. Allow the PBL to set the collimators. Check to make sure the light field is slightly smaller (to account for beam divergence) than the cassette size. Record the size of cassette used and the size of the lig ...
Brain tumor cell density estimation from multi-modal - Sophia
Brain tumor cell density estimation from multi-modal - Sophia

... the accumulation of the contrast agents in both blood vessels and active tumor regions. Then, multi-sequence MR images are synthesized using characteristic image textures for healthy and pathological tissue classes (Fig. ??). We generate synthetic pathological cases with varying tumor location, tumo ...
ACR–SPR Practice Parameter for the Performance of Renal
ACR–SPR Practice Parameter for the Performance of Renal

... patients. Practice Parameters and Technical Standards are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care 1. For these reasons and those set forth below, the American College of Radiol ogy and our collaborating med ...
Applications of Adaptive Optics Scanning Laser Ophthalmoscopy
Applications of Adaptive Optics Scanning Laser Ophthalmoscopy

... averaging multiple images from the same location. But averaging multiple frames in AOSLO is not straightforward. The scanning nature of the system means that each pixel and each line is obtained in sequence. At 30 fps, each frame takes about 30 ms to acquire. During that time the eye will move by si ...
Absolute quantification in SPECT
Absolute quantification in SPECT

... The probability of detection in SPECT consequently depends on the (unknown) location of the decay d and on the linear attenuation coefficients μ(r) of the object. In contrast, in PET imaging the probability only depends on the line of response (LOR) where the decay happened, and not on the exact loc ...
- Frank`s Hospital Workshop
- Frank`s Hospital Workshop

... film and film processors. This system, built on phosphor imaging plate technology, offers the following benefits: • Diagnostic quality images — every time. • Lowers the price of dental imaging by eliminating the need for costly film, chemistry and film processors. • Imaging plates are reusable. • Sa ...
daily electronic portal imaging for morbidly
daily electronic portal imaging for morbidly

... Table 1 summarizes the magnitude of patient positioning error in each direction. The most pronounced direction of positioning error was LR. Mean daily lateral error was 11.4 mm for all patients considered as a group. The median error was 8 mm, and the range was 0 – 42 mm. Error in the lateral direct ...
< 1 ... 54 55 56 57 58 59 60 61 62 ... 159 >

Medical imaging



Medical imaging is the technique and process of creating visual representations of the interior of a body for clinical analysis and medical intervention. Medical imaging seeks to reveal internal structures hidden by the skin and bones, as well as to diagnose and treat disease. Medical imaging also establishes a database of normal anatomy and physiology to make it possible to identify abnormalities. Although imaging of removed organs and tissues can be performed for medical reasons, such procedures are usually considered part of pathology instead of medical imaging.As a discipline and in its widest sense, it is part of biological imaging and incorporates radiology which uses the imaging technologies of X-ray radiography, magnetic resonance imaging, medical ultrasonography or ultrasound, endoscopy, elastography, tactile imaging, thermography, medical photography and nuclear medicine functional imaging techniques as positron emission tomography.Measurement and recording techniques which are not primarily designed to produce images, such as electroencephalography (EEG), magnetoencephalography (MEG), electrocardiography (ECG), and others represent other technologies which produce data susceptible to representation as a parameter graph vs. time or maps which contain information about the measurement locations. In a limited comparison these technologies can be considered as forms of medical imaging in another discipline.Up until 2010, 5 billion medical imaging studies had been conducted worldwide. Radiation exposure from medical imaging in 2006 made up about 50% of total ionizing radiation exposure in the United States.In the clinical context, ""invisible light"" medical imaging is generally equated to radiology or ""clinical imaging"" and the medical practitioner responsible for interpreting (and sometimes acquiring) the images is a radiologist. ""Visible light"" medical imaging involves digital video or still pictures that can be seen without special equipment. Dermatology and wound care are two modalities that use visible light imagery. Diagnostic radiography designates the technical aspects of medical imaging and in particular the acquisition of medical images. The radiographer or radiologic technologist is usually responsible for acquiring medical images of diagnostic quality, although some radiological interventions are performed by radiologists.As a field of scientific investigation, medical imaging constitutes a sub-discipline of biomedical engineering, medical physics or medicine depending on the context: Research and development in the area of instrumentation, image acquisition (e.g. radiography), modeling and quantification are usually the preserve of biomedical engineering, medical physics, and computer science; Research into the application and interpretation of medical images is usually the preserve of radiology and the medical sub-discipline relevant to medical condition or area of medical science (neuroscience, cardiology, psychiatry, psychology, etc.) under investigation. Many of the techniques developed for medical imaging also have scientific and industrial applications.Medical imaging is often perceived to designate the set of techniques that noninvasively produce images of the internal aspect of the body. In this restricted sense, medical imaging can be seen as the solution of mathematical inverse problems. This means that cause (the properties of living tissue) is inferred from effect (the observed signal). In the case of medical ultrasonography, the probe consists of ultrasonic pressure waves and echoes that go inside the tissue to show the internal structure. In the case of projectional radiography, the probe uses X-ray radiation, which is absorbed at different rates by different tissue types such as bone, muscle and fat.The term noninvasive is used to denote a procedure where no instrument is introduced into a patient's body which is the case for most imaging techniques used.
  • studyres.com © 2025