• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
- UTas ePrints
- UTas ePrints

... Currently, the doubly fed induction generator (DFIG)-based wind turbines are widely used because of many salient features [2]. The stator of DFIG is usually directly connected to the utility grid and a partially scaled back-to-back connected voltage source converter (VSCs) links the rotor circuit to ...
Power Quality Analysis in Microgrid
Power Quality Analysis in Microgrid

... Speed Drive (VSD) electronic components with the effect of triple harmonic current, etc. Excessive neutral current level due to the effect of unbalance, leads to overloading of the distribution feeder and transformer with addition of creating heat losses. Also the neutral current caused common mode ...
STP 3 & 4 8.2  Offsite Power Systems
STP 3 & 4 8.2 Offsite Power Systems

... further designed so the loss of an independent right-of-way may necessitate some reduction in generation output, but does not reduce the availability of the offsite supply of power. The transmission system is designed to maintain a voltage variance of +/5% without STP 3 & 4 reactive support in accor ...
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER CCNPP Unit 3
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER CCNPP Unit 3

... The transmission system consists of two circuits. One circuit consists of two separate threephase 500 kV transmission lines (single right-of-way) from the CCNPP site to the Waugh Chapel Substation in Anne Arundel County. The other circuit is a single line circuit from the CCNPP site routed northwest ...
8.0 ELECTRIC POWER
8.0 ELECTRIC POWER

... The U.S. EPR FSAR includes the following COL Item in Section 8.1.1: A COL applicant that references the U.S. EPR design certification will provide site-specific information describing the interface between the offsite transmission system, and the nuclear unit, including switchyard interconnections. ...
FAC-010-2 1 System Operating Limits Methodology for the Planning
FAC-010-2 1 System Operating Limits Methodology for the Planning

... specified in Table 1 is Category P7, Multiple Contingency, addressing “the loss of: 1) Any two adjacent (vertically or horizontally) circuits on common structure, 2) Loss of a bipolar DC line.” Because the RD is addressed in other NERC standards, it should be deleted from FAC-010-2.1 as it adds no a ...


... 3) Allow sufficient room around the inverter to enable easy installation and removal from the mounting surface. 4) Height from ground level should be at least 1 meter. 5) Access panels on the front surface of the inverter allow inspection and maintenance of hardware; and must not be blocked. The fol ...
A Review Paper on Icing and Methods to De
A Review Paper on Icing and Methods to De

... In some conditions, many 220kV or 110kV transmission lines only require less than 25Mvar power source while deicing. Under the worst hazardous condition, it is even harder to get the de-icing power from the ac substation. Therefore, the mobile dc power supply deicer is needed. This deicer obtains th ...
Stakeholder Comparison Comment Rationale Matrix 2010-07-15 AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comparison Comment Rationale Matrix 2010-07-15 AESO AUTHORITATIVE DOCUMENT PROCESS

... NOTE: The AESO is asking market participants to give an initial indication of their support for, or opposition to, the specific Alberta Reliability Standard variances to the NERC requirements referenced below. Such an initial indication assists in the AESO’s practical understanding of the receptivit ...
Picture - SolarToday
Picture - SolarToday

... · There is possiblity of duing to electrical shock and high voltage. · Do not touch the operating component of the inverter, it might result in burning or death. · To prevent risk of electric shock during installation and maintenance, please make sure that all AC and DC terminals are plugged out. · ...
Interconnect Protection of IPP Generators Using Digital Technology
Interconnect Protection of IPP Generators Using Digital Technology

... The Utility Industry Today: Acquisition and Consolidation ...
Aalborg Universitet Advanced Control Architectures for Intelligent MicroGrids, Part I
Aalborg Universitet Advanced Control Architectures for Intelligent MicroGrids, Part I

... engineers have to face a new scenario in which small distributed power generators and dispersed energy storage devices have to be integrated together into the grid. The new electrical grid, also named smart-grid (SG), will deliver electricity from suppliers to consumers using digital technology to c ...
Aalborg Universitet Benchmarking of Voltage Sag Generators
Aalborg Universitet Benchmarking of Voltage Sag Generators

... The highly increased penetration of renewable energy systems, especially photovoltaic (PV) systems and wind turbine (WT) power systems, stirs up research on the integration and control of such environmentally-friendly power generation units. However, it may also cause some negative impact on the pow ...
Advanced Control Architectures for Intelligent MicroGrids, Part I
Advanced Control Architectures for Intelligent MicroGrids, Part I

... engineers have to face a new scenario in which small distributed power generators and dispersed energy storage devices have to be integrated together into the grid. The new electrical grid, also named smart-grid (SG), will deliver electricity from suppliers to consumers using digital technology to c ...
Electric generator
Electric generator

... Ince in 1882, to market his Ferranti-Thompson Alternator, invented with the help of renowned physicist Lord Kelvin.[11] His early alternators produced frequencies between 100 and 300 Hz. Ferranti went on to design the Deptford Power Station for the London Electric Supply Corporation in 1887 using an ...
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER CCNPP Unit 3
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER CCNPP Unit 3

... The transmission system consists of two circuits. One circuit consists of two separate three-phase 500 kV transmission lines (single right-of-way) from the CCNPP site to the Waugh Chapel Substation in Anne Arundel County. The other circuit is a single line circuit from the CCNPP site routed northwes ...
PowerPoint-Präsentation
PowerPoint-Präsentation

... limit. During such angular oscillation period significant cycle variations in voltages, currents, transmission line flows will take place. It is important to damp these oscillations as quickly as possible because they cause mechanical wear in power plants and many power quality problems. The system ...
STP 3 & 4 8.2   Offsite Power Systems
STP 3 & 4 8.2 Offsite Power Systems

... transmission grid associated with the plant is further designed so the loss of an independent right-of-way may necessitate some reduction in generation output, but does not reduce the availability of the offsite supply of power. The transmission system is designed to maintain a voltage variance of + ...
Syllabus B.Tech. ( semester Electrical Engineering), 3
Syllabus B.Tech. ( semester Electrical Engineering), 3

... test, equivalent circuits, back-to-back (Sumpner’s test), phasor diagram, Voltage regulation Efficiency, Condition for maximum efficiency, all day efficiency, parallel operation , ...
Full-power converter based test bench for low voltage
Full-power converter based test bench for low voltage

... features and operation. Finally, measurement results from LVRT tests using a 1.8 MVA full-scale test bench are shown. ...
8.0 ELECTRIC POWER
8.0 ELECTRIC POWER

... The U.S. EPR FSAR includes the following COL Item in Section 8.1.1: A COL applicant that references the U.S. EPR design certification will provide site-specific information describing the interface between the offsite transmission system, and the nuclear unit, including switchyard interconnections. ...
Product note Medium and high voltage generators for
Product note Medium and high voltage generators for

... ABB is a leader in power and automation technologies that enable utility and industry customers to improve their performance while lowering environmental impact. The ABB group of companies operates in around 100 countries and employs about 150,000 people. ABB is the technology and market leader in m ...
Analysis of the Maximum Wind Energy Penetration in the Island of
Analysis of the Maximum Wind Energy Penetration in the Island of

... potential. The average wind speed is more than 7m/sec while in some areas; especially in the eastern part, the annual average speed exceeds 10m/sec. The electricity cost produced by the conventional power plants in Crete is quite high reaching 5 to 7 times the power production on the Mainland. Consi ...
MS Word
MS Word

... Small signal transistors in metal can packages Power products in TO3 packages Small signal transistors in TO92 package Small outline transistors and diodes – low power Small outline transistors and diodes – high power Surface mount devices medium power transistors Through hole package medium power t ...
IEC-61968-2-DTR2
IEC-61968-2-DTR2

... This glossary, accompanying the IEC 61968 series, is the second part in the series that, taken as a whole, define interfaces for the major elements of an interface architecture fo r Distribution Management Systems (DMS). This part of IEC 61968, referred to as Part 2, identifies and explains terms an ...
< 1 ... 5 6 7 8 9 10 11 12 13 ... 48 >

Electrical grid



An electrical grid is an interconnected network for delivering electricity from suppliers to consumers. It consists of generating stations that produce electrical power, high-voltage transmission lines that carry power from distant sources to demand centers, and distribution lines that connect individual customers.Power stations may be located near a fuel source, at a dam site, or to take advantage of renewable energy sources, and are often located away from heavily populated areas. They are usually quite large to take advantage of the economies of scale. The electric power which is generated is stepped up to a higher voltage at which it connects to the electric power transmission network.The bulk power transmission network will move the power long distances, sometimes across international boundaries, until it reaches its wholesale customer (usually the company that owns the local electric power distribution network).On arrival at a substation, the power will be stepped down from a transmission level voltage to a distribution level voltage. As it exits the substation, it enters the distribution wiring. Finally, upon arrival at the service location, the power is stepped down again from the distribution voltage to the required service voltage(s).