• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Grid Connect - damon`s solar training
Grid Connect - damon`s solar training

... NB: if 4 strings of 9 modules were used this would mean 36 modules and 7380w which will not fit within the power rating of the inverter, even according the earlier calculations such an array may be ok. From the table highest output would be 4 strings of eight modules and output wattage 6560 watts. D ...
NPCC Glossary - Northeast Power Coordinating Council
NPCC Glossary - Northeast Power Coordinating Council

... Bottled Energy/Power/Capacity — Energy/Power/Capacity which is available at the source but which cannot be delivered to the point of use because of restrictions in the transmission system. Also referred to as Locked-In Energy/Power/Capacity. A-10, (C-1) Bulk power system — The interconnected electri ...
Small signal analysis for DC bus voltage
Small signal analysis for DC bus voltage

... unified power flow control, high voltage direct current transmission, and power transmission for solar, wind, and other renewable energies. It can be also foreseen that the VSC could become the main connection device of future smart grid technologies, such as in grid energy storage, flexible power t ...
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP FSAR
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP FSAR

... The U.S. EPR FSAR includes the following COL Item in Section 8.2.1.1. A COL applicant that references the U.S. EPR design certification will provide site specific information regarding the communication agreements and protocols between the station and the transmission system operator, independent sy ...
Power Electronics Reliability Comparison of Grid Connected Small
Power Electronics Reliability Comparison of Grid Connected Small

... operating conditions, and consequently has evolved rapidly along with the large scale WECS for generation of electricity either on-grid or off-grid applications. Such a WECS is considered as a complex system of many subsystems ranging from mechanical (rotor, hub, gear box etc.) to electrical (conver ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... inverter with both active and reactive power flow control in a wide range under two types of renewable energy. The power flow is controlled by varying the switching pulse of the power semiconductor device used in the half bridge cascade dual buck multilevel grid-tie inverter. The multicarrier sinuso ...
Utility Static Var Compensator (SVC)
Utility Static Var Compensator (SVC)

... are switched according to inverse time curve with faster behaviour as the instantaneous operation point of SVC is far from 0 MVAr. ° Normal condition: reactive elements are switched in long term to a pre-defined operation condition. The reactive elements are divided in three groups according to its ...
Aalborg Universitet Penetration
Aalborg Universitet Penetration

... impact of wind generation on power system stability. In [4], the author compared the effect of variable speed wind power plant and that of conventional synchronous generator to voltage and transient stability and concluded that the modern wind power plants equipped with power electronic devices and ...
STUDY AND DESIGN OF ENLARGED AUTOMATED TEST STATION FOR GRID AUTOMATION CONTROL CABINETS
STUDY AND DESIGN OF ENLARGED AUTOMATED TEST STATION FOR GRID AUTOMATION CONTROL CABINETS

... Name of Supervisor Olavi Mäkinen The purpose of this thesis was to get acquainted with the routine testing of Control Cabinet which ABB manufactures as part of medium voltage product portfolio. The objective of the thesis was to study how product testing could be automatized due to increasing produc ...
A Distributed Static Series Compensator System for
A Distributed Static Series Compensator System for

... schematically in Fig. 4. DSSC modules can be deployed on select lines, or on all lines. Overall operation of the modules is coordinated using a single (or redundant) communication channel (RF or PLC), with a built-in fail-safe operating mode in case of fast transients (such as system faults) or comm ...
Cascaded Current–Voltage Control to Improve the Power Quality for
Cascaded Current–Voltage Control to Improve the Power Quality for

... grid-connected or vice versa [8]. It is advantageous to operate inverters as voltage sources because there is no need to change the controller when the operation mode is changed. A parallel control structure consisting of an output voltage controller and a grid current controller was proposed in [8] ...
62-814 - Florida Administrative Code
62-814 - Florida Administrative Code

... new transmission line, or new distribution line, that the facility owner has begun a continuous program of actual on-site construction or physical modification of the electrical facility, to be completed within a reasonable period of time. (5) “Department” means the Florida Department of Environment ...
Aalborg Universitet grid-connected voltage source converters
Aalborg Universitet grid-connected voltage source converters

... LCL-filtered voltage source converters [1]. A wide variety of resonance damping technologies have been reported, among which active damping control methods are usually preferred over passive dampers in order to avoid extra power losses [2]. Generally, the active damping can be attained either by int ...
Aalborg Universitet Analysis and design of grid-current
Aalborg Universitet Analysis and design of grid-current

... LCL-filtered voltage source converters [1]. A wide variety of resonance damping technologies have been reported, among which active damping control methods are usually preferred over passive dampers in order to avoid extra power losses [2]. Generally, the active damping can be attained either by int ...
View PDF - Research Trend
View PDF - Research Trend

... variable speed as well as constant speed prime movers, low unit cost, reduced maintenance, rugged and brushless rotors, absence of a separate d.c. source for excitation, absence of moving contacts, inherent overload protection, improved performance due to low transient impedance, natural protection ...
Transmission - Iowa State University
Transmission - Iowa State University

... then the inductances for the three phases are the same. However, construction costs are lower for other configurations such as the vertical or horizontal configurations. For these configurations, the mutual couplings between phases are not identical, and for balanced current loadings, the phases wil ...
Academic paper: Implementation of Shunt and Series FACTS
Academic paper: Implementation of Shunt and Series FACTS

... parameters of Unified Power Flow Controllers (UPFCs) to unify the power flow in electrical power systems. Shunt and Series FACTS devices are used for controlling the transmission voltage, power flow and reducing reactive losses and damping of power system oscillations for high power transfer levels. ...
Downloaded
Downloaded

... compensation will, however, increase the torque capability of the induction machine at speeds outside the normal operating range, resulting in higher maximum torque, and correspondingly higher stresses on the drive-train during the recovery process after the fault [24], [30], [31]. This will be the ...
LIGHTNING THEORY – Explanations
LIGHTNING THEORY – Explanations

... 2.2 Smart Grid and Communications Much has been written about the protection of equipment connected to Smart Grid AC power [see for example www.NEMASURGE.com], but little has been said about protection of Smart Grid communications. Protection of communication links is important, because Smart Grid o ...
Document
Document

... report indicating the affected area or the system, extant of outage and the likely cause of initiation. ...
grid stds
grid stds

... report indicating the affected area or the system, extant of outage and the likely cause of initiation. ...
Aalborg Universitet
Aalborg Universitet

... deep-discharge in one of the ESS and over-charge in the others. Therefore, during the process of charging, it is expected to prioritize the charge of the unit with the smallest state of charge (SoC), and similarly, during the process of discharging, the unit with the highest SoC should provide more ...
cathode-mixing.pdf
cathode-mixing.pdf

... Seems like it could be a way to mix out-of-phase signals plus produce gain at the same time. I doubt if this is new, there's probably a little something about it in RDH4 ;) Depends on where you get your signals from as to what kind of input would be appropriate for you. Imagine again a typical triod ...
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP

... analysis tool used by the transmission operator to determine, in real time, the impact that the loss or unavailability of various transmission system elements will have on the condition of the transmission system to provide post-trip voltages at the switchyard. The information provided will be consi ...
Z35149151
Z35149151

... Vol. 3, Issue 5, Sep-Oct 2013, pp.149-151 and load centers. As the generating stations are far away from the load centers they run over hundreds of kilometers. Since faults can destabilize the power system they must be isolated immediately. Fault analysis is very important issue in power system engi ...
< 1 ... 9 10 11 12 13 14 15 16 17 ... 48 >

Electrical grid



An electrical grid is an interconnected network for delivering electricity from suppliers to consumers. It consists of generating stations that produce electrical power, high-voltage transmission lines that carry power from distant sources to demand centers, and distribution lines that connect individual customers.Power stations may be located near a fuel source, at a dam site, or to take advantage of renewable energy sources, and are often located away from heavily populated areas. They are usually quite large to take advantage of the economies of scale. The electric power which is generated is stepped up to a higher voltage at which it connects to the electric power transmission network.The bulk power transmission network will move the power long distances, sometimes across international boundaries, until it reaches its wholesale customer (usually the company that owns the local electric power distribution network).On arrival at a substation, the power will be stepped down from a transmission level voltage to a distribution level voltage. As it exits the substation, it enters the distribution wiring. Finally, upon arrival at the service location, the power is stepped down again from the distribution voltage to the required service voltage(s).
  • studyres.com © 2025