• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Single-ended triode Amplifier using zero
Single-ended triode Amplifier using zero

... • 600V/120mA at plate, +39V of grid bias and grid exciting voltage of 82V rms for 30W output in A2 class operation (THD: 3.6%) • Grid current varies from 21mA(at idle) to 48mA(at maximum output) for which parallel connection of 5998A for CF is mandatory (for highest drive power) • Current of 6C19P f ...
High Voltage Direct Current(HVDC)
High Voltage Direct Current(HVDC)

... ones. The solid type is in many cases the most economic one. Its insulation consists of paper tapes impregnated with a high viscosity oil. No length limitation exists for this type and designs are today available for depths of about 1000 m. The self –contained oil-filled cable is completely filled w ...
Promotional Bulletin
Promotional Bulletin

... Smart Grid Ready Regulator Control Delivers Automation and Efficiency Utilities, commercial, and industrial facilities need intelligent solutions to improve system voltages and power factor in order to reduce generation demand to achieve significant energy savings. Regulators optimize these savings, ...
Text - kbcheney
Text - kbcheney

... They suggest that after reaching the energy to excite a mercury atom ( Ea ) the electrons accelerate through one free path lambda (  ) before striking and exciting a mercury atom and losing all their kinetic energy. The mean free path is for reasonable conditions much shorter than the distance betw ...
ASU Power Engineering Program: An Overview
ASU Power Engineering Program: An Overview

... Vijay Vittal ...
Easy DENTRON MLA–2500 Conversion using SVETLANA
Easy DENTRON MLA–2500 Conversion using SVETLANA

... The MLA-2500 manual did not specify a typical grid current rating; the only comment made is that 200 mA should not be exceeded. The Svetlana 3CX400A7 data sheet shows five watts maximum grid dissipation. It does not have a specified maximum grid current limit. The 3CX400A7 has about 80% of cathode a ...
Influence of increased wind energy infeed on the transmission network
Influence of increased wind energy infeed on the transmission network

... transmission over several hundreds of kilometers. One crucial factor is that no capacitive charging current at all put a stress on DC cables. Furthermore a DC connection does not transmit any short circuit currents from the shore to the medium-voltage distribution level in the wind farm, thus making ...
Class Z3 Nano Prism Lens 2CFL 2x2
Class Z3 Nano Prism Lens 2CFL 2x2

... The Corelite Z3 recessed luminaire meets the demands of the new energy culture with superior lighting and energy performance. Its engineered optical system delivers luminaire efficiencies greater than 85% while maintaining a soft luminous glow for high visual comfort. Its unique light distribution f ...


... flexible installation options, and durability are required. ...
Report 2015
Report 2015

... effectiveness of power management when using active filters or power supplies with built-in power correctors. Fig.7 shows the screen form regime suppress current harmonics active filter designed to reduce harmonic distortion of the current in the cable and power transformers. Source THDi determined ...
ii. ii. finite-difference time-domain method
ii. ii. finite-difference time-domain method

... Fields can therefore be propagated through the whole grid by alternately evaluating the electric and magnetic field strengths at each time step. This time stepping is continued until either a steady-state response is found or the desired response is obtained. It can be seen that using this technique ...
Performance evaluation of sinusoidal and Space Vector Pulse
Performance evaluation of sinusoidal and Space Vector Pulse

... and energy loses over long power transmission network. It is believed that distributed generation is capable of avoiding the need for the development of new transmission and distribution lines. At the minimum, the grid has to be available as a backup supply so as to increase the system reliability a ...
0901008
0901008

... (Katiraei F 2006). Distributed generation systems are also presented as a suitable solution offer high reliable electrical power supply as well as make up local ac micro grids (Lasseter R et al. 2002). And different kinds of energy resource are available, such as photovoltaic panels, fuel cells, or ...
msc_projects_2016-17
msc_projects_2016-17

... o Network/communication system design o CAD/CAM design and modelling in Matlab/Simulink. ...
AC DC Internet Articles Medium Wikipedia
AC DC Internet Articles Medium Wikipedia

... that AC was the future of electric power distribution, although DC distribution was used in downtown metropolitan areas for decades thereafter. Low frequency (50–60 Hz) alternating currents can be more dangerous than similar levels of DC since the alternating fluctuations can cause the heart to lose ...
ZFAD SERIES
ZFAD SERIES

... • Ballasts T5: Electronic programmed start, normal light output, high power factor, THD less than 10%. Lutron or Advance dimming ballasts as specified. • Ballasts 40W-TT5: Electronic instant start, normal light output, high power factor, THD less that 10%. Optional performances: rapid start circui ...
Modeling and Transient Analysis of Wind Generator during
Modeling and Transient Analysis of Wind Generator during

... 5) Primary Distribution The secondary transmission line terminates at the sub-station where voltage is reduced from 33kv to 11kv 3-phase, 3wire. This forms the primary distribution. From this the large consumers which are using 11kv are distributed from here. 6) Secondary Distribution The electric p ...
Aalborg Universitet Maheshwari, Ramkrishan; Trintis, Ionut; Gohil, Ghanshyamsinh Vijaysinh; Chaudhary, Sanjay
Aalborg Universitet Maheshwari, Ramkrishan; Trintis, Ionut; Gohil, Ghanshyamsinh Vijaysinh; Chaudhary, Sanjay

... A front-end converter is required for sinusoidal input current at unity power factor and realized by a voltage source converter. Typically, the converter is realized using Si based semiconductor devices. However, novel power devices based on wide-bandgap (WBG) semiconductors have become commercially ...
SWITCHGEAR - National Grid
SWITCHGEAR - National Grid

... defined in the Bilateral agreement. The principles of this document applies to equipment connected at other voltages”. This document defines the technical requirements for switchgear connected to the National Grid Electricity Transmission System at 400kV, 275kV, 132kV. The principles of this documen ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... 16 | Page ...
Point out the Limitations and difficulties of HVDC Transmission System
Point out the Limitations and difficulties of HVDC Transmission System

... transmission voltage, the type of terrain, the cost of equipment, and other factors. This particular aspect will be treated Later on in the chapter. Thus dc transmission plays a significant role in situations where it is more economical to generate power at the mine mouth, hydrosite, or gas well and ...
Aurora - Power One Invertor Product Specs
Aurora - Power One Invertor Product Specs

... input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as transformerless operation for high performance efficiencies of up to 97.0%. The wide input voltage range makes the inverter suitable to low ...
Schneider Conext XW Application Note
Schneider Conext XW Application Note

... Conext XW is adaptable and scalable, powering off-grid communities around the world and helping them qualify for renewable energy funding programs to establish reliable, high-quality localized community power plants. By coupling to renewable PV energy generation through the DC system, Conext XW deli ...
OR3425552561
OR3425552561

... source. It provides voltage support by generating or absorbing reactive power at the point of common coupling without the need of large external reactors or capacitor banks. Using the controller, the VSC and the coupling transformer, the STATCOM operation is illustrated in Figure below. The charged ...
SALAZAR et al 2010 Renewable Energy for Desalinization Using Reverse Osmosis
SALAZAR et al 2010 Renewable Energy for Desalinization Using Reverse Osmosis

... degasification before being transferred to the distribution system for use as drinking water. The product passes through an aeration column in which the pH is elevated from a value of approximately 5 to a value close to 7. In many cases, this water is discharged to a storage cistern for later use. ...
< 1 ... 32 33 34 35 36 37 38 39 40 ... 48 >

Electrical grid



An electrical grid is an interconnected network for delivering electricity from suppliers to consumers. It consists of generating stations that produce electrical power, high-voltage transmission lines that carry power from distant sources to demand centers, and distribution lines that connect individual customers.Power stations may be located near a fuel source, at a dam site, or to take advantage of renewable energy sources, and are often located away from heavily populated areas. They are usually quite large to take advantage of the economies of scale. The electric power which is generated is stepped up to a higher voltage at which it connects to the electric power transmission network.The bulk power transmission network will move the power long distances, sometimes across international boundaries, until it reaches its wholesale customer (usually the company that owns the local electric power distribution network).On arrival at a substation, the power will be stepped down from a transmission level voltage to a distribution level voltage. As it exits the substation, it enters the distribution wiring. Finally, upon arrival at the service location, the power is stepped down again from the distribution voltage to the required service voltage(s).