Download Promotional Bulletin

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Electrification wikipedia , lookup

Opto-isolator wikipedia , lookup

Power inverter wikipedia , lookup

Rectifier wikipedia , lookup

Electric power system wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Three-phase electric power wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Stray voltage wikipedia , lookup

Buck converter wikipedia , lookup

Control theory wikipedia , lookup

History of electric power transmission wikipedia , lookup

Electrical substation wikipedia , lookup

Hendrik Wade Bode wikipedia , lookup

Electrical grid wikipedia , lookup

Power engineering wikipedia , lookup

Wassim Michael Haddad wikipedia , lookup

Voltage regulator wikipedia , lookup

Rectiverter wikipedia , lookup

Islanding wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Metadyne wikipedia , lookup

Power electronics wikipedia , lookup

Voltage optimisation wikipedia , lookup

Distributed control system wikipedia , lookup

Alternating current wikipedia , lookup

Control system wikipedia , lookup

Resilient control systems wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Easily Integrate the New Single- and
Multi-Phase CL-7 Regulator Controls into
Your Smarter Grid System
This easy-to-use intelligent control is built to quickly adapt to emerging
changes you can expect from the Smarter Grid. Available as a singleor multi-phase device, the CL-7 control is designed with a full suite of
deployment options to enhance grid efficiency and power quality.
Smart Grid Ready Regulator Control Delivers Automation and Efficiency
Utilities, commercial, and industrial facilities need intelligent
solutions to improve system voltages and power factor in order to
reduce generation demand to achieve significant energy savings.
Regulators optimize these savings, improve power quality, and
minimize voltage fluctuations. In order to tie these great benefits
into a Smart Grid system, an easy-to-use regulator control is
needed.
The Cooper Power Systems CL-7 regulator control is the
newest member of a line of fully integrated controls which
features a modular, universal design, capable of being
deployed with various communications configurations to meet
differing application needs.
CL-7 Regulator Control - The Smarter Choice
The CL-7, a truly scalable regulator control, uses selectable
control strategies and communications to enable users to control
their systems in the optimum manner. The control is designed
to adapt and grow as your system evolves. The CL-7 control
strategy is based on field-proven algorithms, and utilizes
Cooper Power Systems standard front panel and
ProView NXG™ application software.
Available in both single and multi-phase designs, the CL-7
Smarter Grid Ready regulator control with modular, integral
communications easily fits into your existing system. The multiphase control expands on the intelligence of a single-phase
control by adding modular hardware to provide monitoring
and control of additional phases without additional controls.
The CL-7 control has a common look and feel to CBC-8000
capacitor controls and Form 4D switchgear controls for ease of
use and consistency across products.
This Smarter Grid control is designed for:
■■ Increased efficiency in energy delivery
■■ Flexible, easy-to-use communications
■■ Improved productivity
■■ Enhanced power quality
One Cooper | www.cooperpower.com | Online
The CL-7 control can be used with pad-mounted or overhead
voltage regulators.
Product
Name Control
CL-7 Regulator
Flexible, Easy-to-Use Communications
The CL-7 control is specifically designed for remote operation
and retrieval of field measurement data for analysis by integrated
volt/var applications. Benefits from this highly flexible and
programmable control include:
■■ Easy integration into radio networks and SCADA systems
using a variety of communication radios and modems
■■ Communication loss fail-safe modes for grid stability
■■ Unsolicited reporting of state change, field alarms, or
threshold violations for easy monitoring
■■ Available radio-ready
■■ Increased security with password protection
■■ Control configurations upgradable or downloadable through
Cooper Power Systems ProView NXG software
• Locally utilizing the control’s USB connection
• Remotely from office using radio communications
■■ Meets IEC standards supporting 120/240 V and 50/60 Hz
electrical systems for global applications
■■ Single access point communications for all three phases with
multi-phase control
The CL-7 control (single-phase panel shown above) is easily
integrated into a variety of systems and applications.
Improved Productivity
Reduce time in the field, and operating costs with remote control,
scanning, programming, and data log downloads over a secure
network.
■■ Remote, over-the-air settings updates:
• Simplified installation
• Less training needed
• Highly flexible operational settings
■■ Remote retrieval of data:
• Engineers can select nearly 400 data points
• Data logged into data log/sequence of events (SOE)
Three-Phase Power Quality Measurements with One
Multi-phase CL-7 Control
■■ Monitors every aspect of site’s health with full three-phase
voltage, current, var, and harmonic monitoring as well as
monitoring via analog inputs for greater accuracy
■■ Offers refined power quality event monitoring—in the event of
problems or grid anomalies that may need detailed analysis
Whether on a new installation or retrofit (as seen above), the
CL-7 three-phase control is easily programmed in the field.
2
■■ Monitors and improves power quality
■■ Allows customizeable solutions to system imbalance with
advanced features
Voltage Load Tap
Changer (LTC)
Voltage Regulators
and Controls
Capacitor Banks
and Controls
Overhead
Recloser
Transformers
Yukon IVVC
Software
Distribution Automation Solution
Power Factor Correction
Cooper Power Systems offers the full suite of power quality software
and apparatus to support your volt/var management solution. With
unparalleled expertise to make your automation seamless we offer:
Power factor correction is a crucial element in improving energy
efficiency and reducing losses. Regulators are used to correct
the distribution feeder voltage. The graph below represents
before and after effective implementation of Yukon volt/var
management software.
■■ CBC-8000 capacitor bank control
■■ Yukon™ volt/var management automation software
2005/2006 Power Factor
Comparison
for Balch Springs 1905
Power
Factor
■■ Capacitor banks
102.00%
100.00%
■■ CL-7 voltage regulator controls
Optimal Feeder Voltage
Yukon Volt/Var Control (IVVC) software uses capacitors and
regulators to flatten the feeder voltage profile. The regulator
works in conjunction with the capacitor to deliver the optimal
feeder voltage profile. The graph below represents the Yukon
IVVC software flattening the voltage profile – resulting in a
reduction in bus voltage from 122 to 118 volts.
94.00%
92.00%
90.00%
88.00%
86.00%
84.00%
82.00%
Without Volt/Var Automation
With Volt/Var Automation
Two-Day Profile
Voltage Profile: Local Regulation vs Yukon IVVC
Volts
96.00%
0:
00
:
2: 00
00
:0
4: 0
00
:
6: 00
00
:
8: 00
00
10 :00
:0
0
12 :0 0
:0
0
14 :0 0
:0
0
16 :0 0
:0
0
18 :0 0
:0
0
20 :0 0
:0
0
22 :0 0
:0
0:
0: 0 0
00
:
2: 00
00
:0
4: 0
00
:
6: 00
00
:0
8: 0
00
10 :00
:0
0
12 :0 0
:0
0
14 :0 0
:0
0
16 :0 0
:0
0
18 :0 0
:0
0
20 :0 0
:0
0
22 :0 0
:0
0:
0: 0 0
00
:0
0
■■ Voltage regulators
% Power Factor
98.00%
135
Power System Studies for Optimized Results
130
Maximize the benefits from implementing a volt/var management
application with Cooper Power Systems CYME™ Engineering
Services team. We offer power system studies to identify the
best combination of regulation equipment to optimize feeder
voltage profiles and substation var management.
125
120
Local Regulation
Yukon IVVC
115
110
0
2
4
6
8
10
12
14
16
Distance
3
The CL-7 control is specifically designed
to operate voltage regulating apparatus.
This highly flexible control can be
deployed in a number of operational
strategies using site metrics, which
include voltage and current.
Key Operating Features
■■ Single- or multi-phase control
4
■■ Local or remote control of regulators
■■ Multiple operating profiles
5
1
2
8
3
■■ Fully programmable preventative
maintenance tools
■■ Battery backup options to maintain
communications
Key Two-Way Communication
Features
■■ Single access communications
■■ Real-time scanning
■■ Site alarm notifications
■■ Radio-ready control
9
6
7
1. Left-side LEDs to indicate
regulator funtionality
2. USB data ports
3. Ten-key programing area
with LCD display
4. Right-side LEDs
to indicate control
information and
5. Metering-PLUS™ legend
6. Bottom color-coded area
for operating the control
7. Additional manual
controls for multi-phase
applications
8. Commuication status
LEDs
9. External power source and
voltmeter test terminals
Cooper Power Systems
2300 Badger Drive
Waukesha, WI 53188
P: 877.CPS.INFO (877.277.4636)
One Cooper | www.cooperpower.com | Online
B225-12089 • 0113
Cooper Power Systems and Yukon are valuable trademarks of Cooper Industries in the U.S. and other countries.
You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries.
©2012 Cooper Industries. All Rights Reserved.