
Microwave Amplifiers
... For instance if the amplifier is required to drive 50Ω load the voltage across the load may be small, although the corresponding current may be large (there is current gain). For amplifiers functioning at lower frequency (such as IF frequency), it is the voltage gain that is of interest, since imped ...
... For instance if the amplifier is required to drive 50Ω load the voltage across the load may be small, although the corresponding current may be large (there is current gain). For amplifiers functioning at lower frequency (such as IF frequency), it is the voltage gain that is of interest, since imped ...
ERP020-030-040 data sheet revF 26OCT2016
... The ERP020/030/040 LED driver has been designed to operate with a 100 kΩ NTC resistor to provide a knee in the output current regulation between 90°C and 95°C . The graph in Figure 2 shows the reduction in output current as the temperature of the NTC rises above 90°C. For this example, the NTC is a ...
... The ERP020/030/040 LED driver has been designed to operate with a 100 kΩ NTC resistor to provide a knee in the output current regulation between 90°C and 95°C . The graph in Figure 2 shows the reduction in output current as the temperature of the NTC rises above 90°C. For this example, the NTC is a ...
CN-0270:完整的4 mA至20 mA HART解决方案
... The AD5420 contains ESD protection diodes that prevent damage from normal handling. The industrial control environment can, however, subject I/O circuits to much higher transients. To protect the AD5420 from excessively high voltage transients, external power diodes and a surge current limiting resi ...
... The AD5420 contains ESD protection diodes that prevent damage from normal handling. The industrial control environment can, however, subject I/O circuits to much higher transients. To protect the AD5420 from excessively high voltage transients, external power diodes and a surge current limiting resi ...
MAX761/MAX762 12V/15V or Adjustable, High-Efficiency, Low I , Step-Up DC-DC Converters
... (MAX762), or they can be set with two external resistors. With a 5V input, the MAX761 guarantees a 12V, 150mA output. Its high efficiency, low supply current, fast start-up time, SHDN controlling capability, and small size make the MAX761 ideal for powering flash memory. The MAX761/MAX762 have an in ...
... (MAX762), or they can be set with two external resistors. With a 5V input, the MAX761 guarantees a 12V, 150mA output. Its high efficiency, low supply current, fast start-up time, SHDN controlling capability, and small size make the MAX761 ideal for powering flash memory. The MAX761/MAX762 have an in ...
EXERCISES RESONAT CIRCUITS 5.21 The resonant circuit of the
... using an ideal capacitor, C, and a real inductor with L =2 mH and r = 8 The signal is provided by an antenna represented by a real voltage generator (Eg, Rg), being Rg = 20 K. For this propose, the two circuits shown in figure 1(a) and (b) are available. a) b) c) ...
... using an ideal capacitor, C, and a real inductor with L =2 mH and r = 8 The signal is provided by an antenna represented by a real voltage generator (Eg, Rg), being Rg = 20 K. For this propose, the two circuits shown in figure 1(a) and (b) are available. a) b) c) ...
Enlarge - Mouser
... Unless otherwise specified Min/Max limits apply across the −55°C to +125°C temperature range for DS9637AM and across the 0°C to +70°C range for the DS9637ASC. All typicals are given for VCC = 5V and TA = 25°C. All currents into the device pins are positive; all currents out of the device pins are ne ...
... Unless otherwise specified Min/Max limits apply across the −55°C to +125°C temperature range for DS9637AM and across the 0°C to +70°C range for the DS9637ASC. All typicals are given for VCC = 5V and TA = 25°C. All currents into the device pins are positive; all currents out of the device pins are ne ...
MAX1680/MAX1681 125mA, Frequency-Selectable, Switched-Capacitor Voltage Converters _______________General Description
... converters either invert or double the input voltage. They have low output resistance (3.5Ω) and can deliver up to 125mA output current. These devices operate at one of two selectable frequencies: 125kHz/250kHz (MAX1680) and 500kHz/1MHz (MAX1681). This provides the flexibility to optimize capacitor ...
... converters either invert or double the input voltage. They have low output resistance (3.5Ω) and can deliver up to 125mA output current. These devices operate at one of two selectable frequencies: 125kHz/250kHz (MAX1680) and 500kHz/1MHz (MAX1681). This provides the flexibility to optimize capacitor ...
ST3243EB
... protected to ± 8 kV USING IEC 1000-4-2 contact discharge and ± 15 kV using the human body model. The receiver R2 is always active to implement a wake-up feature for serial port. The ST3243E has a proprietary low-dropout transmitter output stage enabling true RS-232 performance from a 3.0 V to 5.5 V ...
... protected to ± 8 kV USING IEC 1000-4-2 contact discharge and ± 15 kV using the human body model. The receiver R2 is always active to implement a wake-up feature for serial port. The ST3243E has a proprietary low-dropout transmitter output stage enabling true RS-232 performance from a 3.0 V to 5.5 V ...
MAX1804 External Four-Input Feedback Integrator for Power Supplies General Description
... The MAX1804 feedback integrator is designed to improve voltage regulation in power-supply systems. The device corrects line- and load-regulation problems, and can be used to compensate for voltage drops in power-management distribution lines. The regulation set point is determined by an external ref ...
... The MAX1804 feedback integrator is designed to improve voltage regulation in power-supply systems. The device corrects line- and load-regulation problems, and can be used to compensate for voltage drops in power-management distribution lines. The regulation set point is determined by an external ref ...
Name - Bowles Physics
... 6. Setup your voltmeter with one wire attached to the BLACK terminal and one wire attached to the 5V terminal. You will read the scale using the BOTTOM set of numbers. If at any point and time the needle goes ALL THE WAY to the right. Move the wire attached to the 5V terminal to the 15V terminal. T ...
... 6. Setup your voltmeter with one wire attached to the BLACK terminal and one wire attached to the 5V terminal. You will read the scale using the BOTTOM set of numbers. If at any point and time the needle goes ALL THE WAY to the right. Move the wire attached to the 5V terminal to the 15V terminal. T ...
AP_Physics_B_-_Series_Circuit_Lab
... 6. Setup your voltmeter with one wire attached to the BLACK terminal and one wire attached to the 3V terminal. You will read the scale using the BOTTOM set of numbers. If at any point and time the needle goes ALL THE WAY to the right. Move the wire attached to the 3V terminal to the 10V terminal. T ...
... 6. Setup your voltmeter with one wire attached to the BLACK terminal and one wire attached to the 3V terminal. You will read the scale using the BOTTOM set of numbers. If at any point and time the needle goes ALL THE WAY to the right. Move the wire attached to the 3V terminal to the 10V terminal. T ...
OP77
... PSRR of 3 mV/V (110 dB) and CMRR of 1.0 mV/V maximum virtually eliminate errors caused by power supply drifts and common-mode signals. This combination of outstanding characteristics makes the OP77 ideally suited for high-resolution instrumentation and other tight error budget systems. ...
... PSRR of 3 mV/V (110 dB) and CMRR of 1.0 mV/V maximum virtually eliminate errors caused by power supply drifts and common-mode signals. This combination of outstanding characteristics makes the OP77 ideally suited for high-resolution instrumentation and other tight error budget systems. ...
EE 442
... usually be ignored, but a good engineer will make sure that assuming the meter to be ideal is a valid assumption. Since a voltmeter is connected in parallel to a circuit or circuit element being measured, it should ideally have an infinitely high resistance. This condition is necessary so the parall ...
... usually be ignored, but a good engineer will make sure that assuming the meter to be ideal is a valid assumption. Since a voltmeter is connected in parallel to a circuit or circuit element being measured, it should ideally have an infinitely high resistance. This condition is necessary so the parall ...