XAPP231
... The multi-drop Virtex-E LVDS line driver adheres to all the standard ANSI/TIA/ EIA-644 LVDS Interface Standard DC input levels as specified in Table 2. The output common-mode voltage typically averages to VCCO/2. Component value derivations for RS, RDIV, and CSLEW can be found in Appendix B on page ...
... The multi-drop Virtex-E LVDS line driver adheres to all the standard ANSI/TIA/ EIA-644 LVDS Interface Standard DC input levels as specified in Table 2. The output common-mode voltage typically averages to VCCO/2. Component value derivations for RS, RDIV, and CSLEW can be found in Appendix B on page ...
Op Amps for Everyone Design Guide (Rev. A)
... latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications a ...
... latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications a ...
Calibration Procedures for Direct
... battery rheostat, Rh. The current divides at M into parts which are nearly equal through the branches MPO and MNO, thus applying approxi mately equal loads on these two branches of the network. The advantage of the circuit of figure 2 is that, since the nominal resistance of each arm; A and B, of a ...
... battery rheostat, Rh. The current divides at M into parts which are nearly equal through the branches MPO and MNO, thus applying approxi mately equal loads on these two branches of the network. The advantage of the circuit of figure 2 is that, since the nominal resistance of each arm; A and B, of a ...
74HC1G66; 74HCT1G66 1. General description Single-pole single-throw analog switch
... To avoid drawing VCC current out of pin Z, when switch current flows in pin Y, the voltage drop across the bidirectional switch must not exceed 0.4 V. If the switch current flows into pin Z, no VCC current will flow out of terminal Y. In this case there is no limit for the voltage drop across the sw ...
... To avoid drawing VCC current out of pin Z, when switch current flows in pin Y, the voltage drop across the bidirectional switch must not exceed 0.4 V. If the switch current flows into pin Z, no VCC current will flow out of terminal Y. In this case there is no limit for the voltage drop across the sw ...
NX3L4684 1. General description Low-ohmic dual single-pole double-throw analog switch
... The NX3L4684 is a dual low-ohmic single-pole double-throw analog switch, suitable for use as an analog or digital multiplexer/demultiplexer. Each switch has a digital select input (nS), two independent inputs/outputs (nY0 and nY1) and a common input/output (nZ). Schmitt trigger action at the digital ...
... The NX3L4684 is a dual low-ohmic single-pole double-throw analog switch, suitable for use as an analog or digital multiplexer/demultiplexer. Each switch has a digital select input (nS), two independent inputs/outputs (nY0 and nY1) and a common input/output (nZ). Schmitt trigger action at the digital ...
General Description Features
... The MAX16000/MAX16001/MAX16003/MAX16004/ MAX16006 offer independent outputs for each monitored voltage. The MAX16001/MAX16002/MAX16004– MAX16007 offer a reset output that asserts whenever any of the monitored voltages fall below their respective thresholds or the manual reset input is asserted. The ...
... The MAX16000/MAX16001/MAX16003/MAX16004/ MAX16006 offer independent outputs for each monitored voltage. The MAX16001/MAX16002/MAX16004– MAX16007 offer a reset output that asserts whenever any of the monitored voltages fall below their respective thresholds or the manual reset input is asserted. The ...
X - IBIS Open Forum
... 9. The I-V data tables should use enough data points around sharply curved areas of the I-V curves to describe the curvature accurately. In linear regions there is no need to define unnecessary data points. 10. The use of tab characters is legal, but they should be avoided as much as possible. This ...
... 9. The I-V data tables should use enough data points around sharply curved areas of the I-V curves to describe the curvature accurately. In linear regions there is no need to define unnecessary data points. 10. The use of tab characters is legal, but they should be avoided as much as possible. This ...
ABB Comp-AC User`s Manual ACS 400 AC Drives for Speed Control
... The ACS 400 should only be mounted vertically on a smooth, solid surface, free from heat, dampness, and condensation. Ensure minimum air flow gaps of 8 in (200 mm) above and below, and 2 in (50 mm) around the sides of the unit. 1 Using the mounting template, mark the position of the mounting holes. ...
... The ACS 400 should only be mounted vertically on a smooth, solid surface, free from heat, dampness, and condensation. Ensure minimum air flow gaps of 8 in (200 mm) above and below, and 2 in (50 mm) around the sides of the unit. 1 Using the mounting template, mark the position of the mounting holes. ...
Chapter 3: Data Converter Architectures
... Kelvin divider or string DAC as shown in Figure 3.4. An N-bit version of this DAC simply consists of 2N equal resistors in series and 2N switches (usually CMOS), one between each node of the chain and the output. The output is taken from the appropriate tap by closing just one of the switches (there ...
... Kelvin divider or string DAC as shown in Figure 3.4. An N-bit version of this DAC simply consists of 2N equal resistors in series and 2N switches (usually CMOS), one between each node of the chain and the output. The output is taken from the appropriate tap by closing just one of the switches (there ...
Document
... Before using the product, read the safety instruction section carefully. Keep the manual in a safe place and available to engineering and installation personnel during the product functioning period. Gefran S.p.A has the right to modify products, data and dimensions without notice. The data can only ...
... Before using the product, read the safety instruction section carefully. Keep the manual in a safe place and available to engineering and installation personnel during the product functioning period. Gefran S.p.A has the right to modify products, data and dimensions without notice. The data can only ...
Chapter 3 Amplifiers with Active Loads – CMOS Amplifiers
... The small signal equivalent circuit of the CMOS amplifier is shown in Fig. 3.1-10. The impedances ro1 and ro 2 are the output impedances of Q1 and Q2 respectively. For ro1 and ro 2 , refer to Section 2.4. ...
... The small signal equivalent circuit of the CMOS amplifier is shown in Fig. 3.1-10. The impedances ro1 and ro 2 are the output impedances of Q1 and Q2 respectively. For ro1 and ro 2 , refer to Section 2.4. ...