MAX15003 Triple-Output Buck Controller with Tracking/Sequencing General Description
... down to 0.6V and delivers up to 15A for each output with excellent load and line regulation. The MAX15003 is optimized for high-performance, small-size power management solutions. The options of coincident tracking, ratiometric tracking, and output sequencing allow the tailoring of the powerup/power ...
... down to 0.6V and delivers up to 15A for each output with excellent load and line regulation. The MAX15003 is optimized for high-performance, small-size power management solutions. The options of coincident tracking, ratiometric tracking, and output sequencing allow the tailoring of the powerup/power ...
30 W 18 to 60-V Input DC/DC Converter w/Auto Track Sequencing
... have the capability of following a common ramp voltage applied to an input called Track. The PTB78560 series is specifically designed to control the Track voltage of any number of nonisolated downstream modules powered from its output. This ensures that the outputs of the downstream modules all rise ...
... have the capability of following a common ramp voltage applied to an input called Track. The PTB78560 series is specifically designed to control the Track voltage of any number of nonisolated downstream modules powered from its output. This ensures that the outputs of the downstream modules all rise ...
CH 215 EXPERIMENT # 1 Ohm`s Law
... 3. Connect the milliammeter in series to complete the circuit between the resistor and point "a", so that all three batteries are included in the circuit. NOTE: Set or connect the meters so that when the switch is closed the meter needle will not deflect off scale, otherwise the meter may be damaged ...
... 3. Connect the milliammeter in series to complete the circuit between the resistor and point "a", so that all three batteries are included in the circuit. NOTE: Set or connect the meters so that when the switch is closed the meter needle will not deflect off scale, otherwise the meter may be damaged ...
MAX15035 15A Step-Down Regulator with Internal Switches General Description Features
... The MAX15035 pulse-width modulation (PWM) controller provides high efficiency, excellent transient response, and high DC-output accuracy. Combined with the internal low on-resistance MOSFETs, the MAX15035 provides a highly efficient and compact solution for small form factor applications that need a ...
... The MAX15035 pulse-width modulation (PWM) controller provides high efficiency, excellent transient response, and high DC-output accuracy. Combined with the internal low on-resistance MOSFETs, the MAX15035 provides a highly efficient and compact solution for small form factor applications that need a ...
UCC28019A 数据资料 dataSheet 下载
... operating in Continuous Conduction Mode (CCM). The controller is suitable for systems in the 100 W to 2 kW range over a wide-range universal ac line input. Start-up current during under-voltage lockout is less than 200 µA. The user can control low power standby mode by pulling the VSENSE pin below 0 ...
... operating in Continuous Conduction Mode (CCM). The controller is suitable for systems in the 100 W to 2 kW range over a wide-range universal ac line input. Start-up current during under-voltage lockout is less than 200 µA. The user can control low power standby mode by pulling the VSENSE pin below 0 ...
AN-1521 POEPHYTEREV-I / -E Evaluation Board User's Guide 1 Introduction
... Please note that TP4 and TP8 are two different return pins for the PoE and AUX inputs, respectively. They are not connected to the same circuit node, and they should not be interchanged. For the output connection, the load can be either a passive resistor or active electronic load. Attention should ...
... Please note that TP4 and TP8 are two different return pins for the PoE and AUX inputs, respectively. They are not connected to the same circuit node, and they should not be interchanged. For the output connection, the load can be either a passive resistor or active electronic load. Attention should ...
... such as in temperature sweeping. Single phase acquisition requires that the system is phased properly and that the lock-in amplifier phase angle is set and fixed at e during the data acquisition. In this mode of operation, some information may be lost since the out of phase signal is not monitored o ...
Capacitor Self
... 1. Laboratory reports will be due at the beginning of each lab meeting. Work that was performed the previous lab meeting is to be documented and turned in the following week at the beginning of the lab period. 2. Late reports will have points deducted at a rate of 10% per weekday. A report will be c ...
... 1. Laboratory reports will be due at the beginning of each lab meeting. Work that was performed the previous lab meeting is to be documented and turned in the following week at the beginning of the lab period. 2. Late reports will have points deducted at a rate of 10% per weekday. A report will be c ...
DCAC_Circuits-Voltmeter_Design_Testing-Student_Guide
... 5. Now, repeat the tests using the full range value of Vin. This time you will take four voltage readings. Use the DMM to adjust the input voltage, to read the voltage drop across the multiplier resistor, and the voltage drop across the meter movement. Also record the reading on the analog lab built ...
... 5. Now, repeat the tests using the full range value of Vin. This time you will take four voltage readings. Use the DMM to adjust the input voltage, to read the voltage drop across the multiplier resistor, and the voltage drop across the meter movement. Also record the reading on the analog lab built ...
MAX3766 622Mbps LAN/WAN Laser Driver with Automatic Power Control and Safety Shutdown
... MD is approximately 2V below VCC. If the loop cannot close due to excess or insufficient photocurrent, a failure is detected by the failure-detection circuit. Internal circuitry prevents the voltage at MD from dropping below VCC - 3.2V. The stability and time constant of the APC feedback loop is det ...
... MD is approximately 2V below VCC. If the loop cannot close due to excess or insufficient photocurrent, a failure is detected by the failure-detection circuit. Internal circuitry prevents the voltage at MD from dropping below VCC - 3.2V. The stability and time constant of the APC feedback loop is det ...
Dual SiC MOSFET Driver Reference Design
... configured by switches to drive as a half-bridge configuration with one side on and with dead time protection. It can also be configured to provide concurrent drive with the requirement to study UIS or double pulse testing. This design can be used with most Microsemi SiC MOSFET discrete and module d ...
... configured by switches to drive as a half-bridge configuration with one side on and with dead time protection. It can also be configured to provide concurrent drive with the requirement to study UIS or double pulse testing. This design can be used with most Microsemi SiC MOSFET discrete and module d ...
EKT112 - UniMAP Portal
... This field acts with or against the permanent magnet. The coil pivots, pushing against the spring, and moving the pointer. The hand points at a scale indicating the electric current. A useful meter generally contains some provision for damping the mechanical resonance of the moving coil and poin ...
... This field acts with or against the permanent magnet. The coil pivots, pushing against the spring, and moving the pointer. The hand points at a scale indicating the electric current. A useful meter generally contains some provision for damping the mechanical resonance of the moving coil and poin ...
AP3440 Description Pin Assignments
... The output voltage is set with a resistor divider from the FB pin. It is recommended to use divider resistors with 1% tolerance or better. Start with a 10kΩ R2 resistor and use the equation 4 to calculate R1. To improve efficiency at very light loads consider using larger value resistors. If the val ...
... The output voltage is set with a resistor divider from the FB pin. It is recommended to use divider resistors with 1% tolerance or better. Start with a 10kΩ R2 resistor and use the equation 4 to calculate R1. To improve efficiency at very light loads consider using larger value resistors. If the val ...
Valve RF amplifier
A valve RF amplifier (UK and Aus.) or tube amplifier (U.S.), is a device for electrically amplifying the power of an electrical radio frequency signal.Low to medium power valve amplifiers for frequencies below the microwaves were largely replaced by solid state amplifiers during the 1960s and 1970s, initially for receivers and low power stages of transmitters, transmitter output stages switching to transistors somewhat later. Specially constructed valves are still in use for very high power transmitters, although rarely in new designs.