
Formula for two-carrier intermodulation distortion
... AVELENGTH conversion is a key technology for the implementation of future flexible WDM networks [1]. Among the possible technologies for its implementation, the use of the semiconductor optical amplifiers (SOA’s) under nonlinear operation has attracted considerable attention, leading to the successf ...
... AVELENGTH conversion is a key technology for the implementation of future flexible WDM networks [1]. Among the possible technologies for its implementation, the use of the semiconductor optical amplifiers (SOA’s) under nonlinear operation has attracted considerable attention, leading to the successf ...
AD827
... feedback resistors is connected between CH2 and Z2 and the other is connected between CH2 and Z2. In Figure 25, Z1 and W1 are tied together, as are Z2 and W2, providing a 3 k feedback resistor for the op amp. The 2 pF capacitors connected between the AD539s W1 and CH1 and W2 and CH2 pins are in para ...
... feedback resistors is connected between CH2 and Z2 and the other is connected between CH2 and Z2. In Figure 25, Z1 and W1 are tied together, as are Z2 and W2, providing a 3 k feedback resistor for the op amp. The 2 pF capacitors connected between the AD539s W1 and CH1 and W2 and CH2 pins are in para ...
Chapter 5 PCM Modulator
... The Operation Theory of PCM Modulation PCM modulation is a kind of source coding. The meaning of source coding is the conversion from analog signal to digital signal. After converted to digital signal, it is easy for us to process the signal such as encoding, filtering the unwanted signal and so on. ...
... The Operation Theory of PCM Modulation PCM modulation is a kind of source coding. The meaning of source coding is the conversion from analog signal to digital signal. After converted to digital signal, it is easy for us to process the signal such as encoding, filtering the unwanted signal and so on. ...
LOW COST VIRTUAL INSTRUMENT FOR FAST ECG MONITORING
... There are three directions that influence the development of medical instruments and establish an early position in a very competitive market: producing safe, high-quality devices for patient care; reduced development time and low cost system. Designing a medical product that has features and capabi ...
... There are three directions that influence the development of medical instruments and establish an early position in a very competitive market: producing safe, high-quality devices for patient care; reduced development time and low cost system. Designing a medical product that has features and capabi ...
AD827 High Speed, Low Power Dual Op Amp Data Sheet (REV. C)
... and a low input offset voltage of 2 mV maximum. Commonmode rejection ratio is a minimum of 80 dB. Power supply rejection ratio is maintained at better than 20 dB with input frequencies as high as 1 MHz, thus minimizing noise feedthrough from switching power supplies. The AD827 is also ideal for use ...
... and a low input offset voltage of 2 mV maximum. Commonmode rejection ratio is a minimum of 80 dB. Power supply rejection ratio is maintained at better than 20 dB with input frequencies as high as 1 MHz, thus minimizing noise feedthrough from switching power supplies. The AD827 is also ideal for use ...
ANSI_SCTE 06 2009
... sum. This procedure describes a technique for measuring this difference using a spectrum analyzer (SA) in the LOG mode. For consistency with existing measurements and specifications, the results of measurements made using any other technique must be correlated with the results from this technique. D ...
... sum. This procedure describes a technique for measuring this difference using a spectrum analyzer (SA) in the LOG mode. For consistency with existing measurements and specifications, the results of measurements made using any other technique must be correlated with the results from this technique. D ...
Velleman Inc.
... generator and bode plotter. With the generator, you can create your own waveforms using the integrated signal wave editor. For automated measurements, it is even possible to generate wave sequences, using file or computer RS232 input. ...
... generator and bode plotter. With the generator, you can create your own waveforms using the integrated signal wave editor. For automated measurements, it is even possible to generate wave sequences, using file or computer RS232 input. ...
DN2.49x - 16 channel 16 bit digitizerNETBOX up to 60 MS/s
... The Gated Sampling mode allows data recording controlled by an external gate signal. Data is only recorded if the gate signal has a programmed level. In addition a pre-area before start of the gate signal as well as a post area after end of the gate signal can be acquired. The number of gate segment ...
... The Gated Sampling mode allows data recording controlled by an external gate signal. Data is only recorded if the gate signal has a programmed level. In addition a pre-area before start of the gate signal as well as a post area after end of the gate signal can be acquired. The number of gate segment ...
AN-16o data sheet v5.3.indd
... The rear panel shall have Neutrik® EtherCon® connectors for A-Net digital signal input and output, as well as for the A-Net Expansion connections. The AN-16/o model shall employ two DB25 multipin connectors for the sixteen analog audio outputs. Its dimensions shall be 19 inches wide, 9 inches deep, ...
... The rear panel shall have Neutrik® EtherCon® connectors for A-Net digital signal input and output, as well as for the A-Net Expansion connections. The AN-16/o model shall employ two DB25 multipin connectors for the sixteen analog audio outputs. Its dimensions shall be 19 inches wide, 9 inches deep, ...
Chapter 1 Time Interval Measurement Literature Review
... This method also allows for high resolutions to be achieved. The resolution as well as the speed is limited mainly by the ADC. Dead-time can be reduced by increasing the discharge rate of the capacitor. This type of time interval measurement is also know as start-stop. A slight modication to the ...
... This method also allows for high resolutions to be achieved. The resolution as well as the speed is limited mainly by the ADC. Dead-time can be reduced by increasing the discharge rate of the capacitor. This type of time interval measurement is also know as start-stop. A slight modication to the ...