
Lecture 1410
... To keep Pheat we must keep I rms as low as possible. The only way to accomplish this is by increasing Erms . In our example Erms 735 kV. To do that we need a device that can change the amplitude of any ac voltage (either increase or decrease) ...
... To keep Pheat we must keep I rms as low as possible. The only way to accomplish this is by increasing Erms . In our example Erms 735 kV. To do that we need a device that can change the amplitude of any ac voltage (either increase or decrease) ...
Introduction_Power_Supply-6-9-10
... • All electronic circuits and equipment need a power supply, usually one that supplies are very specific DC voltage. • A battery is a near perfect DC supply but it is used mainly in portable applications. • Most equipment uses an AC to DC power supply. • In most AC to DC supplies, the 120 volt AC li ...
... • All electronic circuits and equipment need a power supply, usually one that supplies are very specific DC voltage. • A battery is a near perfect DC supply but it is used mainly in portable applications. • Most equipment uses an AC to DC power supply. • In most AC to DC supplies, the 120 volt AC li ...
Self Switching Power Supply
... This is achieved with the help of transistors Q1 and Q2, diodes D7 and D8, and capacitor C2. When a load is connected at the output, potential drop across diodes D7 and D8 (approximately 1.3V) is sufficient for transistors Q2 and Q1 to conduct. As a result, the relay gets energized and remains i ...
... This is achieved with the help of transistors Q1 and Q2, diodes D7 and D8, and capacitor C2. When a load is connected at the output, potential drop across diodes D7 and D8 (approximately 1.3V) is sufficient for transistors Q2 and Q1 to conduct. As a result, the relay gets energized and remains i ...
Wireless Music transmission and reception by IR communication
... pins are configured as outputs when voltage level on them is equal to 0, direct confectioning to LEDs is carried out as it is shown on figure (Low current LED, cathode is connected to output pin). Switches and Pushbuttons: A push button switch is used to either close or open an electrical circuit de ...
... pins are configured as outputs when voltage level on them is equal to 0, direct confectioning to LEDs is carried out as it is shown on figure (Low current LED, cathode is connected to output pin). Switches and Pushbuttons: A push button switch is used to either close or open an electrical circuit de ...
Electricity And Load Shedding Monitoring
... possible for someone to monitor them24 hours. When load shedding occurs in an area the complete power to the concerned area is cut off, these include street lights, traffic signals and important utilities like hospitals, police stations & fire brigade even their power is turned OFF. In this project ...
... possible for someone to monitor them24 hours. When load shedding occurs in an area the complete power to the concerned area is cut off, these include street lights, traffic signals and important utilities like hospitals, police stations & fire brigade even their power is turned OFF. In this project ...
View/Open - Library@Atmiya
... man”),where instead of each socket being individually wired, a cable was brought from the fuse or circuit breaker in the distribution board and wired in sequence to a number of sockets before being taken back to the distribution board and wired to the same fuse or circuit breaker. This provided cons ...
... man”),where instead of each socket being individually wired, a cable was brought from the fuse or circuit breaker in the distribution board and wired in sequence to a number of sockets before being taken back to the distribution board and wired to the same fuse or circuit breaker. This provided cons ...
Problems 2 - MyCourses
... breaker chops the fault current when it has an intantaneous value of 100A. Calculate the restriking voltage set up across the circuit breaker. Neglect resistance. 21. W10.9 A long overhead line has a surge impedance of 500 and an effective resistance at the frequency of the surge of 7/km. If a sur ...
... breaker chops the fault current when it has an intantaneous value of 100A. Calculate the restriking voltage set up across the circuit breaker. Neglect resistance. 21. W10.9 A long overhead line has a surge impedance of 500 and an effective resistance at the frequency of the surge of 7/km. If a sur ...
chapter 8: generation of electricity
... The electrical power produced at Power Stations in Malaysia has a voltage of 11 kV. It is then increased to 275 kV or 500 kV by step-up transformer stations. The high-voltage electrical power is transmitted through overhead cables. The electrical power then enters the Switch Zone and is transmitted ...
... The electrical power produced at Power Stations in Malaysia has a voltage of 11 kV. It is then increased to 275 kV or 500 kV by step-up transformer stations. The high-voltage electrical power is transmitted through overhead cables. The electrical power then enters the Switch Zone and is transmitted ...
Transformer types
A variety of types of electrical transformer are made for different purposes. Despite their design differences, the various types employ the same basic principle as discovered in 1831 by Michael Faraday, and share several key functional parts.