2016China International Conferenceon Electricity Distribution
... a new power conversion equipment, which is based on power electronic converter and high frequency link. SST has the advantage of voltage regulation, reactive power compensation, bi-directional power flow control features etc[3-5]. SST has been regarded as one of the ten most emerging technologies in ...
... a new power conversion equipment, which is based on power electronic converter and high frequency link. SST has the advantage of voltage regulation, reactive power compensation, bi-directional power flow control features etc[3-5]. SST has been regarded as one of the ten most emerging technologies in ...
Document
... Recent advancements in renewable energy have created a need for both high stepup and high efficiency dc-dc converters. These needs have typically been addressed with converters using high frequency transformers to achieve the desired gain. The transformer design, however, is challenging. This paper ...
... Recent advancements in renewable energy have created a need for both high stepup and high efficiency dc-dc converters. These needs have typically been addressed with converters using high frequency transformers to achieve the desired gain. The transformer design, however, is challenging. This paper ...
IDA 200 - Maxtech
... In the past, using traditional measuring methods (often variations of the classical Schering bridge), high voltages up to several thousand volts have been required in order to get accurate results. One of the reasons for this has been the corruption of measurements caused by mains frequency interfer ...
... In the past, using traditional measuring methods (often variations of the classical Schering bridge), high voltages up to several thousand volts have been required in order to get accurate results. One of the reasons for this has been the corruption of measurements caused by mains frequency interfer ...
Introduction Simulation Methodology.
... Once the load line has been designed, it is time for large signal simulation. The input matching section is designed in a similar manner as the output section with the exception that since the return loss can be measured during simulation, it is much easier to either manually tune or automatically o ...
... Once the load line has been designed, it is time for large signal simulation. The input matching section is designed in a similar manner as the output section with the exception that since the return loss can be measured during simulation, it is much easier to either manually tune or automatically o ...
Understanding The Difference Between Three
... Understanding The Difference Between Three-Phase And Single Phase Generators Choosing Between Single-Phase and Three-Phase Generators: The output of single-phase generators is usually limited to 25 kVA. At higher ratings, it is less expensive to draw single-phase power supply from a three-phase gene ...
... Understanding The Difference Between Three-Phase And Single Phase Generators Choosing Between Single-Phase and Three-Phase Generators: The output of single-phase generators is usually limited to 25 kVA. At higher ratings, it is less expensive to draw single-phase power supply from a three-phase gene ...
9. electromagnetic induction
... in the form of heat energy. This loss of energy is known as copper loss. To minimise this energy loss the primary and secondary coils are made of thick copper wire. 63. Magnetic flux leakage : Some magnetic flux leaks in air between primary and secondary. Hence the flux produced in the primary does ...
... in the form of heat energy. This loss of energy is known as copper loss. To minimise this energy loss the primary and secondary coils are made of thick copper wire. 63. Magnetic flux leakage : Some magnetic flux leaks in air between primary and secondary. Hence the flux produced in the primary does ...
Power MultiMeter PMM-1 Version 2.5 Multi
... The Power MultiMeter (PMM-1) version 2.5 is a nextgeneration multifunction instrument for measuring ac or dc voltage, ac primary and secondary current, power, reactive power, power factor, phase angle and frequency of a single or three-phase electrical system. In the single-phase mode, the PMM-1 is ...
... The Power MultiMeter (PMM-1) version 2.5 is a nextgeneration multifunction instrument for measuring ac or dc voltage, ac primary and secondary current, power, reactive power, power factor, phase angle and frequency of a single or three-phase electrical system. In the single-phase mode, the PMM-1 is ...
250W PWM inverter circuit SG3524.
... fluorescent nigth lights and LED light bulbs. For the conventional fluorescent (or discharge) lights is necessary to disconnect the capacitor. Circuit Switching Inverter with modified sine wave typically consists of two parts: 1) DC/DC converter that increases the DC input voltage of 12V (24V, 48V) ...
... fluorescent nigth lights and LED light bulbs. For the conventional fluorescent (or discharge) lights is necessary to disconnect the capacitor. Circuit Switching Inverter with modified sine wave typically consists of two parts: 1) DC/DC converter that increases the DC input voltage of 12V (24V, 48V) ...
Design of a Three-Phase Unity Power Factor Single-Stage
... This section presents the design of the converter based on the mathematical analysis performed in the previous section. The Mathcad software was used to determine the design parameters. The program uses the specifications given in Table 1 as the input data and provides results by simultaneously solv ...
... This section presents the design of the converter based on the mathematical analysis performed in the previous section. The Mathcad software was used to determine the design parameters. The program uses the specifications given in Table 1 as the input data and provides results by simultaneously solv ...
TB#106 Altitude De-rating of Components Placed
... be avoided for line side station class and intermediate class arresters as the conducting impedance of these arresters is so low that when conducted during a fault will cause serious damage. So consider installing distribution class arresters for this application which have higher conducting impedan ...
... be avoided for line side station class and intermediate class arresters as the conducting impedance of these arresters is so low that when conducted during a fault will cause serious damage. So consider installing distribution class arresters for this application which have higher conducting impedan ...
... work piece, therefore, freely available to be touched. We have successfully used voltages between 40 and 75 volts. The Power Supply Let us settle on a nominal 50 volts. To obtain this from our 230v RMS mains supply we need to use a transformer. This is essentially a device which magnetically couples ...
GK-12 Breadboard Tips and Techniques for Digital Circuit
... This circuit provides an easy way of inputting values to a digital circuit. The Dip Switch is the red component and the Resistor Network Pack is the blue component. The Resistor Network Pack shown also in Figure 4, has a pin configuration that must be followed. The side of the resistor pack with the ...
... This circuit provides an easy way of inputting values to a digital circuit. The Dip Switch is the red component and the Resistor Network Pack is the blue component. The Resistor Network Pack shown also in Figure 4, has a pin configuration that must be followed. The side of the resistor pack with the ...
EE 241L-Introductory Circuits Lab-Hassan A Khan
... Familiarize students with basic laboratory instruments used in circuits and electronics ...
... Familiarize students with basic laboratory instruments used in circuits and electronics ...
Transformer types
A variety of types of electrical transformer are made for different purposes. Despite their design differences, the various types employ the same basic principle as discovered in 1831 by Michael Faraday, and share several key functional parts.