• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Medium Voltage Switchgear Condition Assessments
Medium Voltage Switchgear Condition Assessments

... have been specifically developed for the performance of objective, transparent and comparable condition assessments. Siemens condition assessments provide the basis for a targeted maintenance strategy of critical substation assets like high voltage gas insulated switchgear (GIS), high voltage circui ...
AC voltage controller
AC voltage controller

... Input and output characteristics The maximum output frequency and the harmonics in the output voltage are the same as in single-phase circuit. Input power factor is a little higher than single-phase circuit. Harmonics in the input current is a little lower thanthe single- phase circuit due to the c ...
HVTC Product Information
HVTC Product Information

... increasingly important for insulation systems of a lower voltage level. Changing to switching power supply and to IGBT control of induction motors, for instance, raise demands and testing needs for the insulation system. The modular concept of Power Diagnostix’ instruments allows offering customized ...
2# Power Amplifier
2# Power Amplifier

... CLASS B POWER AMPLIFIER ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... A power quality problem exists if any voltage, current or frequency variation results in a failure or in a bad operation of customer’s apparatus. Though, it is important to notice that the quality of power supply implies basically voltage quality and supply dependability. Voltage quality problems re ...
KW3419541958
KW3419541958

... renewable energy applications. Smart Grid organization provides the consumers with the ability to monitor and control energy consumption. This is crucial because as the world population grows the electricity demand will also increase, but at the same time, we will need to reduce our electricity cons ...
mmic amplifier biasing procedure
mmic amplifier biasing procedure

... for the drain-source and a negative supply for the gate-source. If there are multiple gate controls it is assumed for this procedure that they are connected together. Use knob style voltage power supplies – not key pad entry types. The supplies should be used in a floating manner with no connection ...
Power Supplies - ITCK
Power Supplies - ITCK

... • Verify that electricity is getting to the power supply before you do anything. • Power supplies will not start unless they’re connected to a motherboard. • First, try an ATX tester. Many companies make these devices. • Look for one that supports both 20- and 24-pin motherboard connectors as well a ...
T80 TURBOCHARGER™ 80 AMP MPPT BATTERY CHARGE
T80 TURBOCHARGER™ 80 AMP MPPT BATTERY CHARGE

... Point Tracking, battery charge management, state of charge information and communications into a single device. With 80 Amps continuous output, the T80 has the largest capacity in the industry by over 30%. Continuous Power Rating Up to 45oC/113˚F Ambient The T80 TurboCharger™ produces full-rated pow ...
5-13. Magnet Field
5-13. Magnet Field

U3e Test Review Electrical Technology 1
U3e Test Review Electrical Technology 1

Dynamic Resistance
Dynamic Resistance

... In a standard power supply that regulates output voltage the load resistance has a simple calculation: RO = VO / IO LEDs are PN junction diodes with a dynamic resistance that shifts as their forward current changes. When the load is an LED or string of LEDs, the load resistance is replaced with the ...
Paper Title (use style: paper title)
Paper Title (use style: paper title)

... exceeding the critical demand level. Power meters are practical energy saving devices that can help monitor electricity consumption in a plant. This paper discusses the development and implementation of a micro-controller based portable digital power meter that has the capability to measure three ph ...
CIRCUIT IDEAS FOR DESIGNERS Zero
CIRCUIT IDEAS FOR DESIGNERS Zero

... an illustration, a sensor with outputs ranging from 0.1V to 0.5V is used. 0.1V may represent a “0”, or OFFstate, while 0.5V may represent a “1”, or ON-state. A MOSFET device with a precision threshold voltage of 0.4V +/-0.02V can be used. This MOSFET has a threshold voltage sufficiently accurate tha ...
PM100 and PM150 Family Propulsion Inverters
PM100 and PM150 Family Propulsion Inverters

... ‐ PM100DXR provides 450Arms peak current in the smallest package for 400V‐class applica ons  ‐ PM150DZR provides 400Arms peak current for 800V‐class applica ons for 300kW peak output  These version trade useful opera ng life for increased peak power handling in transients.  Example  applica ons incl ...
Voltage Transducer LV 100-400 V = 400 V
Voltage Transducer LV 100-400 V = 400 V

Alternating Current * Learning Outcomes
Alternating Current * Learning Outcomes

Low Power Design of Integrated Systems Assoc. Prof. Dimitrios
Low Power Design of Integrated Systems Assoc. Prof. Dimitrios

... Frequency ...
Current Sensor Tamura - Purdue College of Engineering
Current Sensor Tamura - Purdue College of Engineering

... PCB Design Considerations  2 PCB boards  Power Adapter: Small, narrow to allow for portability.  Base Unit: Must be able to fit a small LCD display (10”)  Microchip Transceiver close to PCB edge.  Current Sensor must be close to PCB edge.  High Electromagnetic Interference from the power ...
PPT
PPT

... what is a tesla coil ...
Energy efficiency of low-voltage installations
Energy efficiency of low-voltage installations

what is a tesla coil
what is a tesla coil

... what is a tesla coil ...
Document
Document

... what is a tesla coil ...
EUP8095  1.5A Linear Li-Ion/Polymer Charger IC with Integrated FET and Charger Timer
EUP8095 1.5A Linear Li-Ion/Polymer Charger IC with Integrated FET and Charger Timer

... The EUP8095 series are highly integrated single cell Li-Ion/Polymer battery charger IC designed for handheld devices. This charger is designed to work with various types of AC adapters or a USB port and capable of operating with an input voltage as low as 2.65V. The EUP8095 operates as a linear char ...
sot-23 bipolar transistors transistor(npn)
sot-23 bipolar transistors transistor(npn)

< 1 ... 957 958 959 960 961 962 963 964 965 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report