• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Crompton Instruments DIN-rail enclosure 3-in-1 current transformers
Crompton Instruments DIN-rail enclosure 3-in-1 current transformers

... enclosure 3-in-1 current transformers A range of 3-in-1 current transformers combine three traditional current transformers in one low profile DIN-rail enclosure. 3-in-1 current transformers can be directly mounted onto a DIN-rail, thus saving installation time where fitting three standard individua ...
COMBOLIGHT New Construction Recessed Trimless - 12V AR70 - 5 Light
COMBOLIGHT New Construction Recessed Trimless - 12V AR70 - 5 Light

... meshplate assembly are all steel construction. Perforated meshplate allows for trimless installation in drywall/plaster ceilings by allowing the ceiling’s mudding compound to be applied right up to the edge of the fixture opening. Includes a beveled “knife-edge” lips to ensure a clean edge. Can acco ...
COMBOLIGHT New Construction Recessed Trimless - 12V AR70 - 3 Light
COMBOLIGHT New Construction Recessed Trimless - 12V AR70 - 3 Light

... assembly are all steel construction. Perforated meshplate allows for trimless installation in drywall/plaster ceilings by allowing the ceiling’s mudding compound to be applied right up to the edge of the fixture opening. Includes a beveled “knife-edge” lips to ensure a clean edge. Can accommodate 0. ...
COMBOLIGHT New Construction Recessed Trimless - 12V AR70 - 2 Light
COMBOLIGHT New Construction Recessed Trimless - 12V AR70 - 2 Light

... assembly are all steel construction. Perforated meshplate allows for trimless installation in drywall/plaster ceilings by allowing the ceiling’s mudding compound to be applied right up to the edge of the fixture opening. Includes a beveled “knife-edge” lips to ensure a clean edge. Can accommodate 0. ...
COMBOLIGHT New Construction Recessed Trimless - 12V AR70 - 4 Light
COMBOLIGHT New Construction Recessed Trimless - 12V AR70 - 4 Light

... meshplate assembly are all steel construction. Perforated meshplate allows for trimless installation in drywall/plaster ceilings by allowing the ceiling’s mudding compound to be applied right up to the edge of the fixture opening. Includes a beveled “knife-edge” lips to ensure a clean edge. Can acco ...
TRANSFORMER TYPES Potential Transformers
TRANSFORMER TYPES Potential Transformers

Open-End-Winding PMSG for Wind Energy Conversion System with
Open-End-Winding PMSG for Wind Energy Conversion System with

... power converters and reduction or even elimination of the mechanical gear stage. Currently state of- the-art commercial wind turbines reach up to 7.5MW, and present developments are aiming at the 10MW milestone. First configurations for WECS used squirrel-cage induction generators operating at fixed ...
With the output diode rectifier configuration at the point when the left
With the output diode rectifier configuration at the point when the left

... Qa source starts to fall, a corresponding voltage will start to develop across Lr as indicated by the figure to the left. This will lead to a di/dt in the primary. As the voltage across Lr increases as the voltage on QB falls, the di/dt in the primary will eventually exceed the di/dt that is occurri ...
Power Tool Safety Terms
Power Tool Safety Terms

... third grounding prong), and are equipped with a polarized two-prong plug (See “Polarized Plug”). Doubleinsulated tools will be marked with a “double square” ( ), or the words “Double-Insulated” on the tool’s rating plate. Ear Protection – Devices such as ear muffs or ear plugs that reduce the intens ...
Bulletin 284 ArmorStart Launch Update
Bulletin 284 ArmorStart Launch Update

... Enhanced Diagnostics ...
Current Transducer HAT 200..1500
Current Transducer HAT 200..1500

... This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. ...
T4900 VAr Load Sharer
T4900 VAr Load Sharer

... increase and decrease pulses to the ­motorized potentiometer. Via the motor­ ized potentiometer, the setting of the automatic voltage regulator (AVR) is done in order to regulate the reactive power with optimum speed and ­stability. The width of the pulses is proportional to the voltage / KVar load ...
ComboLight New Construction Recessed Trimless - 12V AR111 - 4 Light
ComboLight New Construction Recessed Trimless - 12V AR111 - 4 Light

... meshplate assembly are all steel construction. Perforated meshplate allows for trimless installation in drywall/plaster ceilings by allowing the ceiling’s mudding compound to be applied right up to the edge of the fixture opening. Includes a beveled “knife-edge” lips to ensure a clean edge. Can acco ...
ComboLight New Construction Recessed Trimless - 12V AR111 - 3 Light
ComboLight New Construction Recessed Trimless - 12V AR111 - 3 Light

... EMT, C Channel, Tbar fasteners, and bar hangers. Four tabs on housing for securing to structure. Perforated flaps along housing sides for securing trimless insert to fixture and drywall. ...
ComboLight New Construction Recessed Trimless - 12V AR111 - 6 Light
ComboLight New Construction Recessed Trimless - 12V AR111 - 6 Light

... meshplate assembly are all steel construction. Perforated meshplate allows for trimless installation in drywall/plaster ceilings by allowing the ceiling’s mudding compound to be applied right up to the edge of the fixture opening. Includes a beveled “knife-edge” lips to ensure a clean edge. Can acco ...
135w 250w ac dc switching power supply 135w
135w 250w ac dc switching power supply 135w

... operating ambient 110 ℃, and automatic recovery. Operating Temperature: 0℃ to 70℃ ambient, de-rating at 2.5% per degree from 50℃ to 70℃. Operating Humidity: 5% to 90% RH, Non-condensing. Storage Humidity: 5% to 95% RH, Non-condensing. Storage Temperature: -20 to 85 ℃. Vibration: 5 ~ 50 Hz, accelerat ...
Total Power International, Inc. AC/DC EXTERNAL WALLMOUNT
Total Power International, Inc. AC/DC EXTERNAL WALLMOUNT

... (2) Output voltage tolerance is the variation of an output voltage due to the combined effect of output load change from minimum to maximum, input voltage change within the specified input voltage range. For example, with an output voltage tolerance of 20V +/-3%, the output voltage will be between 1 ...
control strategies for generator side converter of direct driven
control strategies for generator side converter of direct driven

... increased excessively since the wind turbine continues to for the WECS and also depends on the conversion generate the power but the grid cannot absorb the fully efficiency. PMSG has received much attention in windgenerated power. Therefore, several literatures regarding energy application because o ...
Stresa, Italy, 26-28 April 2006  IMEC, Kapeldreef 75, 3001 Leuven, Belgium
Stresa, Italy, 26-28 April 2006 IMEC, Kapeldreef 75, 3001 Leuven, Belgium

... ABSTRACT Scaling down of electronic systems has generated a large interest in the research on miniature energy sources. In this paper a closer look is given to the use of vibration based scavengers in industrial environments, where waste energy is abundantly available as engine related vibrations or ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... A load flow study for the considered test system is conducted using Newton-Raphson method [14]. The bus voltage of the system without FACTS (base case) is shown in Fig. 4. From this Figure it can be seen that the us 5 has the lowest voltage magnitude compared to other buses. To analyze the static vo ...
How Things Work - How Everything Works
How Things Work - How Everything Works

... – Input circuit: current/voltage represents sound – Output circuit: amplified “sound” current/voltage – Power circuit: provides power for amplification ...
Power Quality Problems and Solutions
Power Quality Problems and Solutions

... having an input current up to and including 16 A per phase, and beyond 16 A respectively.  IEEE Standard 142-1991 presents a thorough investigation of the problems of grounding and the methods for solving these problems.  IEEE Standard 446-1987 provides guidelines for the selection and application ...
FUNDAMENTALS OF WATER
FUNDAMENTALS OF WATER

... Wye configuration: for office buildings and shopping centers ...
reactive power - Carnegie Mellon Electricity Industry Center
reactive power - Carnegie Mellon Electricity Industry Center

Single-Supply, Low-Power Measurements Of
Single-Supply, Low-Power Measurements Of

... output from the bridge. Gain is easily adjusted with RT. If 1% resistors are used for R4-R7, common-mode rejection will be better than 80dB for gains greater than 200V/V. A CMR of 80dB is quite acceptable in this application. The instrumentation amplifier’s reference connection is made to a 0.5V ref ...
< 1 ... 891 892 893 894 895 896 897 898 899 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report