• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Lab 5 AEV System Analysis 1
Lab 5 AEV System Analysis 1

SNP-HF3 Series
SNP-HF3 Series

Electric Drive System- Kramer on Shaft.pages
Electric Drive System- Kramer on Shaft.pages

没有幻灯片标题 - Cetrex
没有幻灯片标题 - Cetrex

... embedded real time operation system . PSOS system is specially designed for ultra-high reliability and real time quality industrial control system, its cores had been certificated by FAA and FDA, and which had been used in Boeing airplanes.  PSOS system provides many kinds of standard protocol pack ...
SMA CLUSTER CONTROLLER - Professional monitoring and
SMA CLUSTER CONTROLLER - Professional monitoring and

Electrostatic motor
Electrostatic motor

... Principle: This type of motor is based on Coulomb forces, and its energy output is related to the change in electrostatic energy that occurs when charges are moved between the terminals of a high-voltage (HV) supply. This is different from a regular motor, which is based on magnetic forces and the c ...
A Current-Sensorless Digital Controller for Active Power Factor
A Current-Sensorless Digital Controller for Active Power Factor

... must be estimated, often from experimental data, simulations, or simple models. The estimator error covariance matrix P must be initialized to a reasonable value. EKFs, though computationally expensive, are tractable with readily available microprocessors. In addition to matrix multiplications, ther ...
Technical Information CR EB4 N Motor Controller
Technical Information CR EB4 N Motor Controller

... software package the Horiso Smart Motor Control that provides safety soft limits (prevents damage if motor limits fail). Precise facade element/s adjustment in angle degree or mm for facade uniformity, preset stops, programmable parameters and basic scheduling. In addition to controlling 4 motors, e ...
OMD23-2 Micro
OMD23-2 Micro

... In general, unregulated DC (or linear regulated) power supplies are best suited for stepper motor applications. Switching power supplies, which tend to be very cost efficient, are also suited for many stepper motor applications. However, their ability to provide surge currents is limited and may req ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Energy Management and Power Control for a Grid-Connected PMSG Wind Energy …. back power converter is needed. In recent researches, the use of a synchronous generator with full-power backto-back converters is studied and appears to be the most successful configuration. In this topology, boost convert ...
Flash Memory - School of Electrical Engineering and Computer
Flash Memory - School of Electrical Engineering and Computer

... We gained a good knowledge in various power management algorithms. ...
Standards of Power Quality with reference to the Code of Practice for
Standards of Power Quality with reference to the Code of Practice for

... If the quantity and nature of non-linear equipment to be installed in the building cannot be assessed initially, appropriate harmonic reduction devices shall be provided at a later date after occupation. ...
svc
svc

... AC system bus-bar and the low voltage bus-bar to which the thyristor valves are connected. Once the SVC capacity is determined, the best way to design the valve is to use the thyristor current capability at its maximum. Then the minimum necessary AC voltage is derived to obtain the given capacity. T ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Introduction ...
48x36 Poster Template
48x36 Poster Template

... increased memory capacity with low fabrication cost. Due to high write power and long write latency, MLC PCM requires careful power management to ensure write reliability. However, the existing power management schemes applied to MLC PCM result in low write throughput and large performance degradati ...
Study Notes for Test 1
Study Notes for Test 1

... 0 angle (parallel) = least (zero) voltage 14. In an AC generator, what is the relation between conductor and field? Mechanical force is applied to the system to move one part in relation to the other one (which is fixed) in order to generate electrical force (energy). Conductor may rotate within a ...
Innovative power flow management and voltage control technologies
Innovative power flow management and voltage control technologies

... limiting factor under steady-state conditions. The corrective actions include correcting the power factor and compensating the reactive losses in lines by supplying reactive power. High voltage at light load is an undesirable occurrence in the transmission and distribution systems and may be diminis ...
WBPT Series - Panel Mount Isolation Transformers
WBPT Series - Panel Mount Isolation Transformers

... On-line specialists in power products ...
How Computers Work – Course Information
How Computers Work – Course Information

... other power supply is in use. Some new computers, particularly those designed for use as servers, provide redundant power supplies. This means that there are two or more power supplies in the system, with one providing power and the other acting as a backup. The backup supply immediately takes over ...
File
File

Power Quality issues and its improvement in wind
Power Quality issues and its improvement in wind

... electrical power on the grid and leads to large voltage fluctuations. Thus the network needs to manage, the excessive voltage transients which are to be avoided. Today in the variable-speed wind turbine designs, the uses of power electronic converters are mostly used. Thus the issue of harmonic dist ...
Desertec – Energy from the desert – Version 5
Desertec – Energy from the desert – Version 5

... currents under 2,500 A are necessary – in other words with a very high voltage of more than 400 kV. Therefore, in the case of the transmission of large amounts of electric power, high-voltage power lines are preferable for distances over several hundreds of kilometres. Transmission via alternating c ...
Critical Power / UPS Catalog
Critical Power / UPS Catalog

... headaches and frustrations caused by these unannounced power failures. With an SBS battery monitoring system, you can be sure your batteries will continue to support your applications, systems and networks during any power disturbance or failure. Power Generation Products: The generator is only one ...
Experiment 9
Experiment 9

... bias current is the only DC current following through it. Capacitor C2 is a by-pass to insure that the lower end of Rl is at AC ground potential. Since the DC input to the op-amp is 6V, the DC output will also be 6 V DC level. The circuit has gain of plus one, and the output is duplicated of the inp ...


... oscillations and sensitivity. Recently, there are many successful applications of fuzzy logic control to power system problems. The phase-plane fuzzy logic control is one of them that has been proved to work in many power system applications. For example, the implementation of fuzzy logic control ba ...
< 1 ... 893 894 895 896 897 898 899 900 901 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.