• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Restructuring of First Courses in Power Electronics and
Restructuring of First Courses in Power Electronics and

... be structured such that students learn the basic principles on which these devices and components operate in order to control them optimally in exciting new applications. This restructuring has the added benefit of drawing students to these fields where otherwise, due to lack of student interest, co ...
INTERNETWORKING I
INTERNETWORKING I

... Is UTP a good conductor of electricity? (yes/no) Why or why not? It’s copper-based, which is an excellent conductor. What would happen if the ground wire for a networking device in one location has a slightly different potential than another device on the same network segment? The closed circuit of ...
power loss ride-through in a variable speed drive system
power loss ride-through in a variable speed drive system

... the grid needs support most. However in this case, the VSDs must not make things worse in the grid, and as a consequence a variety of national grid codes has appeared over the last decade, defining how operation under a degraded grid has to be, depending on the actual or on the statistically most li ...
1110/1120 electro-magnetic locks
1110/1120 electro-magnetic locks

Läs mer - DiViTec
Läs mer - DiViTec

... each independently able to handle the complete frame power ...
"Shoot from the hip" Electronic trouble
"Shoot from the hip" Electronic trouble

... Salesman’s view of solving instrument problems New! ...
Aalborg Universitet Advanced Control Architectures for
Aalborg Universitet Advanced Control Architectures for

Bertan 230 Series of High Voltage Power Supplies, Spellman High
Bertan 230 Series of High Voltage Power Supplies, Spellman High

Model Question Paper BASIC ELECTRICAL ENGINEERING
Model Question Paper BASIC ELECTRICAL ENGINEERING

... coil has 500turns and a galvanometer of 450 Ω is connected in series with it. The coil is moved in 0.1s from the given field to another field of 0.3mWb. Find the average induced emf and the average current through the ...
4-20 mA SENSOR / TRANSMITTER MODEL TR-1000
4-20 mA SENSOR / TRANSMITTER MODEL TR-1000

... ELECTRICAL CODE REQUIREMENTS. NOTE: To prevent shorting problems do not leave ground wire to box bare (if one is used) – cover with electrical tape. ...
Terminator I/O Discrete Input Modules
Terminator I/O Discrete Input Modules

... modules include jumpers for selecting the internal 24 VDC power supply available for 2- and 3-wire field devices. Clearly labeled triple stack terminals make it easy to wire 2- and 3-wire devices ensuring clean wiring with only one wire per termination. ...
here - ECE - University of Maryland
here - ECE - University of Maryland

Lesson C7-1
Lesson C7-1

... Is a measure of electrical power.  Electrical power is work being done by current(amperage) under pressure(voltage) in getting the electrons through the resistance of wires and machines back to the ...
Aalborg Universitet Advanced Control Architectures for Intelligent Microgrids—Part II
Aalborg Universitet Advanced Control Architectures for Intelligent Microgrids—Part II

... microgrids should mostly be designed as self-sustainable, if frequent load shedding is not intended [12]. Having an inter-tie would also expose the microgrids and utility grid to their respective inner disturbances, like harmonics, unbalance and other power quality “noises”. To better isolate the gr ...
Electrical Coordination - System Studies
Electrical Coordination - System Studies

... Included in the analysis is an examination of insulation withstand ratings of equipment. A withstand rating is the highest test voltage that can be applied to an electrical insulation system without causing flashover, puncture or other such electrical failure. System overvoltage scenarios are compar ...
Power Supply Tracker Can Also Margin Supplies
Power Supply Tracker Can Also Margin Supplies

... down by 10%. The first tracking cell connected to pins TRACK1 and FB1 causes the 2.5V supply to track this 3.3V supply during power up and power down as shown in Figure 4. The tracking cell connected to TRACK2 and FB2 is used to margin the 2.5V supply up and down by 10%. The operation of the circuit ...
Automatic Voltage Control
Automatic Voltage Control

The PV Combiner Multiple Strings May Need Combiner
The PV Combiner Multiple Strings May Need Combiner

... The dc PV Disconnect Photo 4. Dead front PV source-circuit combiner (photo credit AMTec Solar) ...
PDS secondo le IEC 61800-n
PDS secondo le IEC 61800-n

BMS-24-40 OG
BMS-24-40 OG

... Should a product manufactured by DuraComm fail or malfunction due to manufacturing defect, or faulty component, DuraComm, at its option, will repair or replace the faulty product or parts thereof, which, after examination by DuraComm, prove to be defective or not operational according to specificati ...


... • Lower Repair Costs: Repair costs in detecting problems at an early stage are often only 1% of the cost incurred if failure occurs during normal operation of an asset . • Predict Catastrophic Failures: Maximize revenue from the generator by reducing risk of catastrophic asset failures and schedul ...
transformers - BRUSH SEM sro
transformers - BRUSH SEM sro

... The AE series on-load tapchangers are built on the successful results of the design of the AT range. The AE uses many common parts from the AT including the complete drive mechanism. This range has a maximum of 17 tapping positions (16 steps) and is possible for linear regulation and 33 tapping posi ...
HRC100/s
HRC100/s

PDF
PDF

... Abstract Wind energy has become one of the significant alternative renewable energy resources because of its abundance and the strong drive for its commercialization. Dynamic electric load variations and wind velocity excursions cause excessive changes in the prime mover kinetic energy and the corre ...
±80°/sec Yaw Rate Gyro, SPI Interface Evaluation Board ADIS16080/PCB Preliminary Technical Data
±80°/sec Yaw Rate Gyro, SPI Interface Evaluation Board ADIS16080/PCB Preliminary Technical Data

... The ADIS16080’s digitized outputs can be accessed using the 4wire serial port interface (SPI) signals on J1: SCLK, CS, DOUT and DIN. For specific information on using the ADIS16080’s SPI interface, refer to the ADIS16080 datasheet. Auxiliary functions, such as the two 12-bit ADC inputs, can be acces ...
< 1 ... 708 709 710 711 712 713 714 715 716 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report