• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
A2000 Multifunctional Power Meter
A2000 Multifunctional Power Meter

... Up to 12 measured values can be selected for storage to memory. The measuring instrument acquires these measured values once every 300 ms and stores them first to intermediate memory. These values are then averaged in accordance with the selected sampling rate and are stored to permanent memory as m ...
NCS5651 2 Amp PLC Line Driver Product Preview
NCS5651 2 Amp PLC Line Driver Product Preview

TS1 - Faculty of Engineering
TS1 - Faculty of Engineering

... application of large load, a loss of generation, a loss of large load, or a fault (short circuit) on the system. In most disturbances, oscillations are such magnitude that linearization is not permissible and nonlinear equations must be solved to determine the stability of the system. On the other h ...
High Voltage DC Circuit Breakers Design, Operation and Expectation
High Voltage DC Circuit Breakers Design, Operation and Expectation

... voltage can be adjusted by switching a second resistor into the circuit  Calculating the optimum switching time is a fourdimensional problem where the turn off time, toff is expressed as a function of the resistor, switching time, t1, and the two resistor values, Ro and R1. ...
Model of Voltage Source Inverter for Estimation Methods with
Model of Voltage Source Inverter for Estimation Methods with

Publication : Cost-Optimal Design of a 3
Publication : Cost-Optimal Design of a 3

... supplying power to the station auxiliaries like boiler feedpump, FD and ID fan-motors etc. 2) For supplying two transmission lines from a point at two different voltage levels. 3) Some of the H.V. transformers use star-connection for both primary and secondary winding for economic advantages. This p ...
Transmission lines
Transmission lines

...  Analyzing GTL on a transmission line  Transmission line impedances  DC measurements  High Frequency measurements Using Transmission Lines ...
Aalborg Universitet
Aalborg Universitet

... URING the last years photovoltaic (PV) generation has emerged as one of the most used renewable energy sources (RES) due to current trend at the reduction on its installation cost [1]. However, the intermittent nature of PV generators, added together with unpredictable load fluctuations, may cause i ...
Phono Stage - Classic Valve Design
Phono Stage - Classic Valve Design

... The Dynaco PAS series of pre-amplifiers has been one of the most successful and popular pre-amplifiers in history. They are reliable, hold their resale value and are incredibly popular “blank slates” to modify. The PAS-K phono board is an upgrade for the original PAS series of pre amplifiers designe ...
Power supply require..
Power supply require..

... could decide to jump over the edge of it. To test for this, a capacitor was mounted on a circuit board similar to the one used in the LNA and a voltage was applied over it. At 210 V no sign of breakdown was evident. Our power supply limited us to apply higher voltages. The rated voltage of this capa ...


... the energy from any renewable sources to conventional AC systems. The Photo Voltaic (PV) energy system is a very new concept in use, which is gaining popularity due to increasing importance to research on alternative sources of energy over depletion of the conventional fossil fuels world-wide. Among ...
Leak Mk1 FM Tuner restoration
Leak Mk1 FM Tuner restoration

... had a low emission triode section. I suspect that some of the tubes may even be the original fitment as they were Mullard manufactured, made in the UK; Checked the resistance measurement from HT to chassis – rather low, rising to only around 5kohms after an initial dip to almost zero on the meter as ...
Digital Storage Oscilloscopes - TPS2012B, TPS2014B
Digital Storage Oscilloscopes - TPS2012B, TPS2014B

... Unlike ground-referenced oscilloscopes, the TPS2000B input connector shells are isolated from each other and from earth ground. Within the specified 600 VRMS maximum float voltage, IsolatedChannel technology keeps current from flowing between the TPS2000B input BNC shells or from any BNC shell to ea ...
AVS2000 PRO
AVS2000 PRO

... Monster’s exclusive Clean Power circuitry, and several other groundbreaking designs. Richard’s background and research into amplifier and capacitors led to the development of the Servo-DC feedback circuit for power amplifiers – a technique used by virtually every manufacturer today. His status as th ...
RMF-‐1048 AC to DC Power Supply Owners Guide
RMF-‐1048 AC to DC Power Supply Owners Guide

design_review
design_review

Tips for connecting 24-volt power
Tips for connecting 24-volt power

... transformer be connected to earth ground. In the United States, for example: The National Electrical Code® requires (section 250.20) grounding transformers for AC systems of less than 50 volts if the primary voltage exceeds 150 volts to ground or if the main transformer supplying power to the buildi ...
Network Theorems
Network Theorems

... • Note – This is accomplished in the same manner as Thévenin equivalent resistance ...
EEE- Interview Question with Answers
EEE- Interview Question with Answers

... Electrical interview question: What is "pu" in electrical engineering? Answer: Pu stands for per unit and this will be used in power system single line diagram there it is like a huge electrical circuit with no of components (generators, transformers, loads) with different ratings (in MVA and KV). T ...
FSL136MRT Green-Mode Fairchild Power Switch (FPS™) FSL136MRT — Green-Mode Fair
FSL136MRT Green-Mode Fairchild Power Switch (FPS™) FSL136MRT — Green-Mode Fair

... PWM comparator inverting input voltage, together with the SenseFET current, slowly after startup. The typical soft-start time is 15ms. The pulse width to the power switching device is progressively increased to establish the correct working conditions for the transformers, inductors, and capacitors. ...
PDF
PDF

... Today we are using many portable devices such as LED products, notebooks, mobile phones, and car electronic products. And these products use the power converter for application. The challenges for the designer to provide consumers better conveniences are, to improve the conversion efficiency of powe ...
Overview of SLAC X-band program and Application to FELs
Overview of SLAC X-band program and Application to FELs

... Offsetting these advantages are the requirements of: - High power (100’s MW) HV pulses with fast rise times (100’s ns). - High surface gradients in the klystrons, waveguide transport system and accelerator structures. ...
electrical services
electrical services

CURRENT TRANSFORMERS (CT) OPERATED METER CHANGES
CURRENT TRANSFORMERS (CT) OPERATED METER CHANGES

VIPer100 THE MOST ADVANCED MONLITHIC SOLUTION FOR
VIPer100 THE MOST ADVANCED MONLITHIC SOLUTION FOR

... COMP pin is shorted to ground. After that, the current source is shut down, and the device tries to start up by switching again. ...
< 1 ... 589 590 591 592 593 594 595 596 597 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report