• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Hierarchical Coordinated Control of Multi bus
Hierarchical Coordinated Control of Multi bus

Disclaimer - IEEE Industrial Electronics Society
Disclaimer - IEEE Industrial Electronics Society

FML9
FML9

... otherwise dispose of the same, no express or implied right or license to practice or commercially exploit any intellectual property rights or other proprietary rights owned or controlled by ROHM CO., LTD. is granted to any such buyer. Products listed in this document are no antiradiation design. ...
CK22543550
CK22543550

... operate. Main DG technologies include gas turbines, microturbines, wind turbines generator, fuel cells, photovoltaic cell (PV cell), etc. DGs come in different forms such as on-site gas or diesel fired turbines, reciprocating engines, micro-turbines, small hydro induction generators, wind turbines a ...
Evaluates:  MAX8569A/MAX8569B MAX8569 Evaluation Kit General Description Features
Evaluates: MAX8569A/MAX8569B MAX8569 Evaluation Kit General Description Features

... Place a shunt between pins 2-3 of jumper JU_ to shut down the MAX8569_ and reduce the input current to less than 1µA. During shutdown, the BATT_ input is connected to VOUT_ through the inductor and the internal synchronous rectifier. This allows the input battery (rather than a separate backup batte ...
Technical Data Sheet HCI634H - Winding 311 and 312
Technical Data Sheet HCI634H - Winding 311 and 312

... against sustained over-excitation, caused by internal or external faults. This de-excites the machine after a minimum of 5 seconds. Over voltage protection is built-in and short circuit current level adjustments is an optional facility. ...
EEE 107-3240
EEE 107-3240

... Where RV is the virtual damping resistance at harmonic frequencies. With this harmonic current reference (9), the DG unit essentially works as a small equivalent harmonic resistor at the end of the feeder, when it is viewed at power distribution system level [33], [34]. By providing sufficient dampi ...
Lab Title - Chabot College
Lab Title - Chabot College

... Set the dial selector on the DVM to the “Ω” position to measure resistance. To measure resistance, the DVM supplies a fixed current to the speaker, and measures the resulting voltage across the speaker. Because of this, it is very important to NEVER attempt to measure resistance of a component when ...
Electricity and Multimeters
Electricity and Multimeters

... but not amps. Measure voltage and amps while the electricity is on. Measure resistance and continuity while the electricity is off. For the specific details of how to use your multimeter, consult the manual, which explains what you can measure with the multimeter and how to use it. Multimeters are s ...
Power Supply Measurement and Analysis
Power Supply Measurement and Analysis

... Switch-Mode Power Supply Basics The prevailing DC power supply architecture in most modern systems is the Switch-Mode Power Supply (SMPS), which is known for its ability to handle changing loads efficiently. The power signal path of a typical SMPS includes passive, active, and magnetic components. T ...
DOWN LOAD HERE - NOISE LABORATORY CO.,LTD.
DOWN LOAD HERE - NOISE LABORATORY CO.,LTD.

... the LSS-15AX series simulators provide a testing facility for up to 15kV test voltage without sacrificing safety and ease of use. The LSS-15AX simulators generate the two combination pulses 1.2/50 µs (8/20 µs) and 10/700 µs (5/320 µs) Fully programmable and easy to use simulator that meets and far e ...
Tetra® LED Systems Power Supply
Tetra® LED Systems Power Supply

... NOTE: For CSA approval, a disconnect/toggle switch of appropriate rating needs to be placed within 29.5 ft. (9 m) of primary side of the power supply. The minimum rating of the switch must be either 120 or 220 Volts AC. The switch must also support twice the amount of input current. NOTE: When inst ...
Electrical Engineering Standards
Electrical Engineering Standards

... Identify and explain how electrical problems relate to basic electron theories concepts (conductors, insulators, electrical charges, voltage, current, resistance, capacitance, and inductance). Apply mathematical concepts and laws in understanding and solving problems with electrical circuits ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Lotfi Zadeh , the father of fuzzy logic , claimed that many sets surrounding us are defined by a non – distinct by a non – distinct boundary. He extern ad two valued logic , defined by pair of binary { 0 , 1}, to the whole continuous internal [0,1], there by introducing a gradual transition of false ...
Diode Applications
Diode Applications

... same as the input. The average VDC or VAVG = Vp/ ...
stepper motors - WordPress.com
stepper motors - WordPress.com

MT-FD 6 - Newmar
MT-FD 6 - Newmar

... Now press and hold the SET button until the red status LED begins flashing then release the button. The red LED will stay illuminated at this point. Note: At this point, if programming mode has been entered unintentionally or if you don’t want to save any changes, press the RESET switch to abort pro ...
Generator Compatibility of Passive Filters - Trans-Coil
Generator Compatibility of Passive Filters - Trans-Coil

A Family of Single-Stage Switched
A Family of Single-Stage Switched

... (buck, boost, buck–boost, cuk, zeta, and sepic) have been used in various electronic applications due to their numerous advantages such as simple structure, good performance, high efficiency, easy design, and ...
DA100J Series - Murata Power Solutions
DA100J Series - Murata Power Solutions

... i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously ...
Aalborg Universitet Model Predictive Current Control for High-Power Grid-Connected Converters with
Aalborg Universitet Model Predictive Current Control for High-Power Grid-Connected Converters with

... In order to keep power losses within acceptable margins, high-power converters (around 5 MW) present a critical limitation on the switching frequency. Available power semiconductors are usually limited to operate below 600 HZ. For a 3-level neutral point connected (NPC) converter this means that the ...
Submersible Instruction Manual
Submersible Instruction Manual

... To open the L.V. circuit manually, move the handle from “C” (closed) to “O” (open). When it coincides with the “O” position, the L.V. circuit is open. The breaker operating handle can be operated with a hot line tool. Oil Immersed Expulsion Fuses Transformers protected with an internal oil immersed ...
Inverter_User
Inverter_User

Pololu - Understanding Destructive LC Voltage Spikes
Pololu - Understanding Destructive LC Voltage Spikes

SNP-G20
SNP-G20

< 1 ... 587 588 589 590 591 592 593 594 595 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report