• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
$doc.title

... liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typic ...
Power Electronics - Dr. Imtiaz Hussain
Power Electronics - Dr. Imtiaz Hussain

converter provides EMC and isolation in PLC
converter provides EMC and isolation in PLC

... minimum? At the same time, how do you fend off a diversity of challenges tied to wide input voltage range, multiple outputs, small solution size, electromagnetic compatibility (EMC), and high reliability? Consider factory automation and control end equipment segments such as programmable logic contr ...
DC Motors
DC Motors

... Analyze Kirchhoff’s current law in a three-wire Y-Y three phase circuit and in a four-wire Y-Y three phase circuit using a basic three phase generator that produces three balanced voltages with a Y connected balanced purely resistive loads. ...
Optimal DC Power Distribution System Design for Data Center with
Optimal DC Power Distribution System Design for Data Center with

Presentation - TI Training
Presentation - TI Training

BSL310C-DF - Philips Bodine
BSL310C-DF - Philips Bodine

... 1. Ensure the LED load’s rated power is greater than or equal to the power output of this emergency LED driver. This is to ensure that this emergency product will not produce more power than the LED load can handle, thus ensuring that the LED load will not be damaged when the system is in the em ...
FM 24-24 Chapter 3 Multiplex Equipment Section I. Time Division
FM 24-24 Chapter 3 Multiplex Equipment Section I. Time Division

Using Thyristors in Heating Applications
Using Thyristors in Heating Applications

... To provide full protection for thyristor devices is not straightforward. In particular the use of HBC fuses (type gG or gL in Europe) alone will most probably not offer adequate protection against either overload or short circuit. Special semiconductor fuses (type aR) provide correct protection agai ...
PmodHB5™ Reference Manual Overview 1 Functional Description 2
PmodHB5™ Reference Manual Overview 1 Functional Description 2

... The PmodHB5 utilizes a full H-Bridge circuit to allow users to drive DC motors from the system board. Two sensor feedback pins are incorporated into the motor connection header and are specifically designed to work with the Digilent motor/gearbox. ...
Process Variation Aware Dynamic Power Management in Multicore Systems with
Process Variation Aware Dynamic Power Management in Multicore Systems with

... The following subsections discuss our core selection/thread-tocore mapping and DVFS strategies for both problems P1 and P2. 5.1 Core Selection and Thread-to-Core Mapping In DSM technology nodes, due to process variations, each core in a homogeneous CMP behaves heterogeneously, dissipating different ...
AN1889
AN1889

bi-dirctional three-level front- end converter for
bi-dirctional three-level front- end converter for

x8407_projects
x8407_projects

An Investigation of Short Circuit Analysis in Komag Sarawak
An Investigation of Short Circuit Analysis in Komag Sarawak

... programs that are equipped with comprehensive analysis platform for the design, simulation and operation of industrial power system. The short circuit analysis function is the fundamental or basic functions that are available in almost all computer aided power system analysis programs. These program ...
High Power Microwave Sources and Applications
High Power Microwave Sources and Applications

... High power microwaves (HPM) is an imprecise term used by several communities [1]. In the DoD it pertains primarily to the generation of high peak power bursts of narrowband (coherent) electromagnetic radiation spanning the frequency range of approximately 1GHz to 100 GHz. The technology used to gene ...


SLP-2002 Stereo Balanced Vacuum Tube Preamplifier
SLP-2002 Stereo Balanced Vacuum Tube Preamplifier

... outputs. The main power fuse holder and an IEC standard AC power cable connector are the remaining features of the rear panel. We chose to offer XLR and RCA inputs for the main source components so that music lovers have more choice in matching the SLP-2002 with other high performance audio componen ...
Introduction, Features and Applications
Introduction, Features and Applications

... Introduction, Features and Applications Introduction The KL-8078 are high performance microstepping drivers based on one of the most advanced technologies in the world today. They are suitable for driving 2-phase and 4-phase hybrid stepping motors. By using advanced bipolar constant-current chopping ...
Usare foto Tact switches - ib-lab
Usare foto Tact switches - ib-lab

Application guide for power factor testing of power
Application guide for power factor testing of power

D N IAGNOSTIC EWS
D N IAGNOSTIC EWS

... Iris Power DCR-50 Ramp Tester Shows New Talents Continued... ...
the manual
the manual

... If the monitor suddenly stops working... • Turn the outputs of your sound system down or off. • Repeat the steps in the Troubleshooting sections above before continuing to the next steps. • Carefully check to see if the amplifier’s back plate is hot. If the monitor has been running at its highest ...
Voodoo Labs Pedal Power 2 Manual
Voodoo Labs Pedal Power 2 Manual

... If you have any questions, this is the first place to look! Can I use my U.S. model Pedal Power in a country with 230V mains? No. Pedal Power units purchased in North America should only be powered with 120VAC. Attempting to use 220-240VAC mains directly will cause permanent damage to your Pedal Pow ...
Nuclear Plant Cable Aging Management in the U.S. with
Nuclear Plant Cable Aging Management in the U.S. with

< 1 ... 549 550 551 552 553 554 555 556 557 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report