• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
IEEE Transactions on Magnetics
IEEE Transactions on Magnetics

... The structure of the ZVS-SVM controlled three-phase PWM rectifier is similar to the ACRDCL converter. With the special SVM scheme proposed by the authors, both the main switches and the auxiliary switch have the same and fixed switching frequency. The reverse recovery current of the switch be turned ...
AN-9050 FDMF6704 Power Loss Calculation  Introduction
AN-9050 FDMF6704 Power Loss Calculation Introduction

... When designing a Sync Buck application, critical design parameters are input/output voltage, output current, switching frequency and inductor value. Typically input and output voltages are decided by the system application. Switching frequency and output inductor are then optimized to get the best t ...
Optical fibre current sensor for electrical power engineering
Optical fibre current sensor for electrical power engineering

... Also electric transducers of measured quantitative have undergone qualitative changes. Optical transformers of the current making use of the magnetooptic phenomenon belong to the unconventional transformers. Presently, they are being more and more implemented in electric power systems. Measurement s ...
Alternator voltage regulator with load response control
Alternator voltage regulator with load response control

... The alternator voltage is compared with a reference voltage in an amplifier. This device senses the battery voltage in two ways: the B+ pin and the S pin. The last could be left unconnected. In this condition the battery voltage is sensed from the VGO pin, otherwise the S pin is used. This second co ...
Superconductors As Surge Current Protectors
Superconductors As Surge Current Protectors

Physics with a car headlamp and a computer
Physics with a car headlamp and a computer

... students to answer relevant questions as opposed to just verifying a well-known law. By using the computer in this way, students can be given an awareness of many mathematical techniques used in data analysis not otherwise possible because of time constraints or students lack of knowledge. Templates ...
AND9038 - Efficiency Improvements Using DSN2 Schottky Diodes
AND9038 - Efficiency Improvements Using DSN2 Schottky Diodes

... “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. ...
construction, dynamically balanced • Full-featured microprocessor based con-
construction, dynamically balanced • Full-featured microprocessor based con-

MAX9737 Mono 7W Class D Amplifier General Description Features
MAX9737 Mono 7W Class D Amplifier General Description Features

... Note 1: Thermal performance of this device is highly dependent on PCB layout. See the Applications Information section for more detail. Note 2: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-layer board. For detailed information on ...
Kopasakis2006-SolidOxideCellModel.pdf
Kopasakis2006-SolidOxideCellModel.pdf

... reformer, humidifiers, and diffusers. In this system, the fuel cell, together with the heat exchanger, effectively replaces the combustor section in a typical gas turbine engine as shown in figure 2. The GTE and the FC both generate electrical energy, which is delivered to electrical loads by an ele ...
Switch Mode Power Supplies For Electrostatic Precipitators
Switch Mode Power Supplies For Electrostatic Precipitators

... V-I curves A and B indicate that SMPS is capable of providing 10 to 20% more average secondary voltage and 60 to 100% more corona power when compared to conventional 60 Hz power supplies. A 10% increase in average secondary voltage is typically equivalent to a migration velocity enhancement factor ...
Source Impedance - Controlled Power Company
Source Impedance - Controlled Power Company

WECC VGITF White Paper - Draft - Western Electricity Coordinating
WECC VGITF White Paper - Draft - Western Electricity Coordinating

... reactive power requirements for variable generation power plants. Early plants were only required to operate at the unity power factor at the point of interconnection. FERC issued Order 661-A in 2005, requiring a transmission planner to determine the power plant reactive power requirements on a case ...
Technician Handbook For Huurre WIC With Petrol Genset
Technician Handbook For Huurre WIC With Petrol Genset

... This lamp can be put off by pressing the ‘Reset’ button once. NOTE: Also in the cases of single phasing, phase reversal etc. in the network supply, the same is disconnected and the generator starts and run connect generator power to the selected unit automatically. IMPORTANT: The 12 V car battery on ...
5W, Qi Wireless Power Receiver with Integrated Rectifier and LDO
5W, Qi Wireless Power Receiver with Integrated Rectifier and LDO

... signal by rectifying the AC power from the transmitter and storing it on a capacitor connected to VRECT. During the "ping" phase, the rectifier provides about 5V at the VRECT pin. An internal linear voltage regulator provides the supply voltage for the digital section to enable WPC communication. To ...
TPS92010 数据资料 dataSheet 下载
TPS92010 数据资料 dataSheet 下载

Voltage profile - Mon`s group Sydney
Voltage profile - Mon`s group Sydney

... Ф output = Ф 1 + Ф 2 depending on the position of moving coil. ...
ILT 195 - Northeast Alabama Community College
ILT 195 - Northeast Alabama Community College

... knowledge (troubleshooting) needed to perform stated entry-level industry competencies. The performance objective of this course is for each student to apply foundational knowledge (troubleshooting) to electronic problems and exercises encountered in class. INDUSTRY COMPETENCIES/STUDENT PERFORMANCE ...
Chapter 24 Electrical Power
Chapter 24 Electrical Power

... master relay, which connects power to the electrical system. The master switch is in series with the field switch so that the complete electrical system can be cut of by means of a master switch. The voltage regulator, receiving power from the battery via the master switch in combination with the fi ...
Quasi-z-source inverter for photovoltaic power generation
Quasi-z-source inverter for photovoltaic power generation

... Photovoltaic (PV) power generation is becoming more promising since, the introduction of the thin film PV technology due to its lower cost, excellent high temperature performance, low weight, flexibility, and glassfree easy installation. However, there are still two primary factors limiting the wide ...
KSH45H11 PNP Epitaxial Silicon Transistor Absolute Maximum Ratings
KSH45H11 PNP Epitaxial Silicon Transistor Absolute Maximum Ratings

... which, (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. ...
Design of Low Power Sequential Circuit by using Adiabatic
Design of Low Power Sequential Circuit by using Adiabatic

... language which means no energy transfer with outer environment, this process is known as a thermodynamic. So the dissipated heat loss in adiabatic logic families is very less. But in CMOS logic design, charge flow in the circuit is studied and many methods can be used for minimizing power dissipatio ...
Sure-Lites ELX6 spec sheet ADX041053
Sure-Lites ELX6 spec sheet ADX041053

... power connectors, integral handles, and simple wiring combine to make installation of the ELX Series Exit fast and easy. AC Only versions are standard 120/277 VAC or can also be specified as 120/347 VAC. If necessary, ELX Series electronics trays, housings, and trim assemblies can be shipped separat ...
$doc.title

... Most  runs  at  two  power  levels  (5W  and  6.5W  glow  –  fan  is  0.5W  so  total  power  is  5.5   or  7W)   Noise  is  both  Seebeck  voltage  &  input  power  varia
RM450 Rack Kit - Aim-TTi
RM450 Rack Kit - Aim-TTi

... naturally by the design of the rack, and it may be possible to omit the lower 1U space. An equivalent situation could exist at the top of a rack. The exact ventilation requirements for a particular situation will depend upon ambient temperatures within the rack (Note 2). Note 1 - Heat Generation and ...
< 1 ... 490 491 492 493 494 495 496 497 498 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report