• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
FSQ0370RNA, FSQ0370RLA Green Mode Fairchild Power Switch (FPS™) FSQ0370RNA / FSQ0370RLA
FSQ0370RNA, FSQ0370RLA Green Mode Fairchild Power Switch (FPS™) FSQ0370RNA / FSQ0370RLA

... 4. Maximum practical continuous power in an open-frame design with sufficient drain pattern as a heat sink at 50°C ambient. ...
Elimination of the motor neutral voltage
Elimination of the motor neutral voltage

... Elimination of the motor neutral voltage:  The neutral voltage is not required in the proposed method, only the three motor terminal voltages need to be detected. Elimination of the fixed phase shift circuit:  The proposed specific average line to line voltage inherently lags 30 electric degrees c ...
Evaluation Board User Guide
Evaluation Board User Guide

... responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Analog Devices reserves the right to change devices or specifications at any time without notice. Trademarks and registered trademarks are the ...
M-1500/2000 Power Amplifier
M-1500/2000 Power Amplifier

... The fans should be kept free of all obstructions and be accessible to cool fresh air when possible. It is important that the fans be used in a dust free environment. 2. CIRCUIT BREAKER When the circuit breaker is cut, push to reset again. In case of occuring trouble to the set by means of overload o ...
The Mosfet Transistor
The Mosfet Transistor

... Insulated Gate Bipolar Transistor (IGBT)  For both types of IGBT, a positive voltage VGE will involve a conduction channel in p-type layer underneath the gate  As VCE is higher than Vbi of J1, then MOS part of the device will inject electrons in n-type layer  N-type layer is the base of a PNP tra ...
CHAPTER 3 Week 7
CHAPTER 3 Week 7

... 5.3 Maximum Power Transfer Maximum Power Transfer Theorem - To obtain maximum power from a source with a fixed internal resistance, the resistance of the load must be made the same as that of the source. ...
FSFR2100 — Fairchild Power Switch (FPS™) for Half-Bridge Resonant Converters
FSFR2100 — Fairchild Power Switch (FPS™) for Half-Bridge Resonant Converters

... The soft-start time is three to four times of the RC time constant. The RC time constant is as follows: ...
Applications Circuits: Current Measurement
Applications Circuits: Current Measurement

... amp is “tricked” into acting as a differential amplifier by floating its output and common. These are then fed to the inputs of the INA117, where the common mode voltage is rejected. An applications circuit using this approach is shown in Figure 7- 6. The OPA277 op amp preamplifier provides a gain o ...
7a- Curr Meas Apps
7a- Curr Meas Apps

... amp is “tricked” into acting as a differential amplifier by floating its output and common. These are then fed to the inputs of the INA117, where the common mode voltage is rejected. An applications circuit using this approach is shown in Figure 7- 6. The OPA277 op amp preamplifier provides a gain o ...
Aalborg Universitet A Comprehensive Review of Low-Voltage-Ride-Through Methods for Fixed-Speed
Aalborg Universitet A Comprehensive Review of Low-Voltage-Ride-Through Methods for Fixed-Speed

... Recently, many power system operators in Europe and other regions of the world have begun expanding and modifying their interconnection requirements for wind farms through technical standards, known as grid codes [9, 10]. One of the critical requirements concerning the grid voltage support is the lo ...
POOR & BAD CIRCUITS
POOR & BAD CIRCUITS

... This is what is known as a half wave rectification circuit. This configuration was very popular with the old valve circuits, where the rectifier was either a valve or a selenium rectifier, so why is it a poor circuit? Several reasons – The transformer is only providing power on the +Ve half cycles – ...
ONS321A5VGEVB / ONS321B12VGEVB Evaluation Board User`s
ONS321A5VGEVB / ONS321B12VGEVB Evaluation Board User`s

User Guide - Texas Instruments
User Guide - Texas Instruments

Torque Ripple Calculation of the Two
Torque Ripple Calculation of the Two

... form one phase. The stator windings can be configured to either a serial or parallel two-phase system. Normally the windings are identical. The windings which forms one phase of the motor are connected like shown on Fig. 1. Two diametrically opposite stator poles are of opposite magnetic polarity. T ...
Generator Design Using MotorSolve v6
Generator Design Using MotorSolve v6

... Design of outputs is different for motors and generators Optimal generator design will be different than optimal motor design • Most software tools use the fact that motors can act as generators and address only motors • Need specialized generator design tool ...
BDTIC www.BDTIC.com/infineon Power Management PX3516
BDTIC www.BDTIC.com/infineon Power Management PX3516

... The PX3516 functionality is driven by the PWM signal transitions. When the PWM signal performs a transition between low state to high state (PWM voltage higher than 2.4V) the Low Side MOSFET is turned off, after the turn off delay propagation time. Then the High Side MOSFET is turned on, after the t ...
packaging
packaging

... (different classes depending on required current drive) ...
Chapter 8 UFSAR Table of Contents
Chapter 8 UFSAR Table of Contents

... hydro plants, fossil-fueled plants, and nuclear plants supplying electric energy over a transmission grid consisting of various voltages up to 500 kV. VEGP Units 3 and 4 are located in eastern Burke County, Georgia, approximately 26 miles southeast of Augusta, Georgia and 100 miles northwest of Sava ...
Slide - Indico
Slide - Indico

...  Efficient postmortem ELQA diagnostic methods to be applied during commissioning and operation with beam must be established ...
packaging
packaging

... (different classes depending on required current drive) ...
POWER SYSTEM HARMONICS A Reference Guide to Causes
POWER SYSTEM HARMONICS A Reference Guide to Causes

... This means that a 6-pulse (or 3-phase) rectifier will exhibit harmonics at the 5th, 7th, 11th, 13th, 17th, 19th, 23rd, 25th, etc. multiples of the fundamental. As a rough rule of thumb, the magnitudes of the harmonic currents will be the fundamental current divided by the harmonic number (e.g. the m ...
Using the Loss-Free Resistor concept to design a simple ac
Using the Loss-Free Resistor concept to design a simple ac



... The Power over Ethernet(PoE) is designed to extract power from a conventional twisted pair Category 5 Ethernet cable, conforming to the IEEE 802.3af Power-over-Ethernet (PoE) standard. IEEE 802.3af allows for two power options for Category 5 cables. The PoE module signature and control circuit provi ...
Accidents in home and environment
Accidents in home and environment

... electricity through tissue plains. These burns can be further divided into high tension or voltage and low tension/ voltage burns. • Electrical conduction through tissues causes damage due to the conversion of electrical energy to thermal energy, the amount of which is dependant upon tissue resistan ...
IGBT or MOSFET: Choose Wisely
IGBT or MOSFET: Choose Wisely

... In the battle between MOSFETs and IGBTs, either device can be shown to provide the advantage in the same circuit, depending on operating conditions. How does a designer select the right device for his application? The best approach is to understand the relative performance of each device. And know t ...
< 1 ... 421 422 423 424 425 426 427 428 429 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.