• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CHAPTER 3 DIODES
CHAPTER 3 DIODES

... Eliminate all the time varying signals (ac voltage and current sources) for operation point analysis Use rapid analysis or accurate analysis to obtain dc voltage and current at operating point Q Determine the parameters of small‐signal models from Q Replace the devices with small‐signal models a ...
Dahlander motor
Dahlander motor

... 2. to protect the motor from overloads and hence, destruction. Switching devices performing this latter function are referred to as motor protecting switches or protecting switch combinations. Motor protecting switches for single-speed motors without thermal contact A motor protection switch can ope ...
FUTURE ANALYSIS TOOLS FOR POWER QUALITY P. Ribeiro, R
FUTURE ANALYSIS TOOLS FOR POWER QUALITY P. Ribeiro, R

The Transformer Principle
The Transformer Principle

... When a conductor or coil is moved in a stationary magnetic field it cuts the lines of magnetic flux and an EMF is induced in the conductor or coil. This same principle also applies when a conductor is held stationary and the magnetic flux is made to change or vary. Now consider an alternating curren ...
Digital Transmission (Line Coding) EE4367 Telecom. Switching & Transmission Prof. Murat Torlak
Digital Transmission (Line Coding) EE4367 Telecom. Switching & Transmission Prof. Murat Torlak

Transformers and Alternating Current
Transformers and Alternating Current

... In this way the transformer changes the voltage. Power=voltage current remains the same for the two circuits. If the secondary voltage is lowered, it is known as a step-down transformer. If the secondary voltage is raised, it is called a step-up transformer. PHY 202 (Blum) ...
DIVISION 16 - ELECTRICAL
DIVISION 16 - ELECTRICAL

... L. Uninterruptable Power Supply – Furnishes power to load even on complete loss of building power. Will supply power for a limited time, to allow an orderly shutdown of equipment without causing damage, or loss of data. M. Withstand Rating – Maximum fault current, at maximum rated voltage, in RMS sy ...
FB32957961
FB32957961

... the output of QQ1 as 4.Then we get the divider output i.e., div out as QQ1. If mode select input is 001 and dc=0, then the output of QQ1 is 6.Then we get the divider output i.e., div out as QQ1. CASE 3: If mode select input is 010 and dc=1, then the output of QQ2 is 8.Then we get the divider output ...
OWNER`S MANUAL
OWNER`S MANUAL

... signal ground to the chassis/AC ground. The top position lifts the amplifier’s signal ground. In a properly designed system (for safety purposes and to minimize noise), amplifiers should be connected to ground through the AC line cord. Also, whenever possible, the signal source equipment should shar ...
SMES Modeling Performance Analysis Michael
SMES Modeling Performance Analysis Michael

... It was also observed that the location where the combined compensator is connected is important for improvement of the overall system dynamic performance. Although the use of a reactive power controller seems more effective in a load area, this simulation study shows that a STATCOM with real power c ...
MICREL DC to DC Converters
MICREL DC to DC Converters

MP7752 - Monolithic Power System
MP7752 - Monolithic Power System

... class-D audio amplifiers exhibit the high fidelity of class-AB amplifiers at high efficiency. The MP7752 includes an internal circuit which allows the system to shut down automatically after the absence of the audio signal is detected. This feature is used for energy-using products and battery opera ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676

... The power generation capacity electric boing 787 air bass A380 airplanes is above 1.4 MW and 850KW respectively. In order to reduce the weight of the aircraft electric power should be delivered at a high voltage With low current and low conduction losses this technology leads to simpler Equipment an ...
energies The Impacts of Power Switching Devices to the Thermal
energies The Impacts of Power Switching Devices to the Thermal

... According to [6], [9]-[12], the thermal cycling behavior inside the power switching devices is one of the key failure mechanisms and is close related to its life time as well as the cost/size of the corresponding heat sink system. Therefore, it is interesting to investigate the thermal cycling relat ...
Analysis of Series-Parallel Resonant Inductive Coupling Circuit
Analysis of Series-Parallel Resonant Inductive Coupling Circuit

... been research to find out most suitable topology for particular application such as battery charging [6-10]. While there are other topologies that may be used, the parallel secondary architecture is beneficial for battery charging because of its constant current source characteristics, which occurs ...
FR011L5J (11mΩ, -30V) Low-Side Reverse Bias / Reverse Polarity
FR011L5J (11mΩ, -30V) Low-Side Reverse Bias / Reverse Polarity

... qualification devices, where the predicted failure rate is less than 0.01% at the specified voltage for 24 hours. It is intended to indicate the device’s ability to withstand transient events that exceed the recommended operating voltage rating. Specification is based on qualification devices tested ...
Comprehensive Study of Forward and Fly Back Converter for
Comprehensive Study of Forward and Fly Back Converter for

... observation and discuss. This discussion conclude that this can be achieved by combining both of topology together by using some suitable switching devices such as MOSFET which has special feature of low switching time. In This paper the merging of forward and fly back converter proposed topologies ...
CH33509513
CH33509513

... Pardeep Kumar, Susmita Mishra, Amrita Singh / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 3, Issue 3, May-Jun 2013, pp.509-513 5. Design of Low Power Adder Using LP XOR and XNOR The Low power full adder which takes lesser number of trans ...
All You Need To Know About Power over Ethernet (PoE)
All You Need To Know About Power over Ethernet (PoE)

... When implementing a PoE system, numerous physical infrastructure limitations must be taken into consideration. CAT-5 cables commonly used in Ethernet infrastructure, for one, may carry voltage levels of no more than 80 Vdc, and RJ-45 connectors are rated at a maximum of 250 Volts and 1.5A, while saf ...
TPS63000-Q1 数据资料 dataSheet 下载
TPS63000-Q1 数据资料 dataSheet 下载

... The TPS63000 devices provide a power supply solution for products powered by either a two-cell or three-cell alkaline, NiCd or NiMH battery, or a one-cell Li-Ion or Li-polymer battery. Output currents can go as high as 1200 mA while using a single-cell Li-Ion or Li-Polymer battery, and discharge it ...
product pdf
product pdf

... sleek and modern appearance and due to its small and unobtrusive size, this fixture will become almost invisible on the structure to which it will be installed. The STR9 is a totally sealed, low voltage fixture with an external power supply, so there should be no need to ever access the fixture for ...
MAX3803 Evaluation Kit ________________ General Description Features _________________________
MAX3803 Evaluation Kit ________________ General Description Features _________________________

... to ensure that no direct short exists between the supply voltage and supply ground. Normal dccoupled operation with all positive supplies causes permanent damage to laboratory test equipment because a dc path exists from the power supply to the ports of the oscilloscope or BERT. The MAX3803 EV kit m ...
Voltage Rating
Voltage Rating

... A common practice when electricians are testing fuses is to touch the end caps of the fuse with their probes. Contrary to popular belief, fuse manufacturers do not generally design their knife-blade fuses to have electrically energized fuse caps during normal fuse operation. Electrical inclusion of ...
LEIA SAFETY CHARTER
LEIA SAFETY CHARTER

EM8559A
EM8559A

< 1 ... 374 375 376 377 378 379 380 381 382 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.