• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
A 93% efficient LED driver solution for the US market
A 93% efficient LED driver solution for the US market

CHAPTER-8 SWITCHYARD EQUIPMENT- HV Bus Bars
CHAPTER-8 SWITCHYARD EQUIPMENT- HV Bus Bars



... available. While BGA packages are best suited for large-scale projects where absolutely minimum PCB occupancy is required, there is often debate on whether TH packages or SMT packages should be used for smaller projects. Many electronics hobbyists still prefer TH packages because TH components can b ...
Space Vector PWM and Model Predictive Control for Voltage Source
Space Vector PWM and Model Predictive Control for Voltage Source

... VSI in order to calculate the future optimal value of the load current. The optimal value of the objective function is applied during the next sampling period. Fig. 8 shows the VSI MPC control system. Fig. 9 outlines step by step implementation process of MPC for predictive control of VSI. First all ...
2010 B1 Session Questionnaire ( doc , 67 kB ) - SC B1
2010 B1 Session Questionnaire ( doc , 67 kB ) - SC B1

... Group Meeting SC B1 Insulated Cables, 24th August, 2010 Questionnaire Please return completed Questionnaire at the exit of the meeting room or send it before 30th September, 2010 to : E Bergin (Convenor, Customer Advisory Group, Study Committee B1) ...
1250W PowerVerter RV Inverter/Charger with Hardwire Input/Output
1250W PowerVerter RV Inverter/Charger with Hardwire Input/Output

... feature temporarily provides up to 150% of the continuous output for 1-60 minutes, and DoubleBoost TM inverter output feature delivers up to 200% of the continuous output for up to 10 seconds, providing the extra power needed to cold start heavy-duty tools and motorized equipment. When hardwire AC i ...


High-Efficiency Step-Down Low Power DC
High-Efficiency Step-Down Low Power DC

... with design and process enhancements to maximize performance over extended temperatures. Custom temperature ranges available ...
Elec Machinery\US\84\8405
Elec Machinery\US\84\8405

VT1418 - CPU Board Resets Sporadically
VT1418 - CPU Board Resets Sporadically

bp5220a : Power Modules
bp5220a : Power Modules

... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
service reminder
service reminder

... Flash” lockouts and premature hot surface igniter failures. Some of these faults are field repairable and other faults required new software to resolve the problem. This new software is being incorporated in today’s controls, which are more “fault tolerant”. (See IFC date code reference table on pag ...
Review on Performance of Static Random Access Memory
Review on Performance of Static Random Access Memory

... rotation speeds and arm movement delays today, randomaccess memory (RAM) takes the form of integrated circuits (IC). Random Access Memory is normally associated with volatile type of memory such as DRAM memory modules, In these stored information is lost if the power is removed, many efforts have be ...
MV Switchgear 5kVMetal-Clad Indoor
MV Switchgear 5kVMetal-Clad Indoor

... specified by the local utility. The construction shall conform to the utility company’s metering standards as specified by the local utility’s specifications. It shall also conform to the general electrical and construction design of the switchgear specified above. ...
effect of lead wire lengths on protector clamping
effect of lead wire lengths on protector clamping

A DCM Based PFC CUK Converter-Speed Adjustable BLDC
A DCM Based PFC CUK Converter-Speed Adjustable BLDC

... simple way to achieve PFC and dc-link voltage control, but at the cost of high stress on PFC converter switch. On the other hand, the current multiplier approach offers low stresses on the PFC switch, but requires three sensors for PFC and dc-link voltage control. Depending on design parameters, eit ...
Introduction to WEBENCH Power Designer
Introduction to WEBENCH Power Designer

... Which control mode to use for various applications? – COT  cheap and easy, always stable but variable frequency & ripple – Voltage mode  most common in Buck, cheap and easy low component count – Current mode  most common for CCM in Boost, Buck-Boost, SEPIC, Flyback, very good performance but need ...
Inductor Discharging
Inductor Discharging

... Inductor Discharging • Assume an Inductor is initially fully charged with a constant 100 mA (IO) current flow. It acts like a short circuit… • When the switch is opened, the inductor will immediately induce a voltage to keep the 100 mA current constant. − KVL can be used to calculate this induced v ...
Electronically Commutated Motors
Electronically Commutated Motors

... 4. Disconnect switches are not fused. The power leads must be protected at the point of distribution in accordance with the fan dataplate. 5. All units must be electrically grounded in accordance with local codes or, in the absence of local codes, with the latest edition of the National Electrical C ...
An Improvement of Transient Current Response of Load
An Improvement of Transient Current Response of Load

... Email:[email protected]) **( Assistant professor, Department of Electrical & Electronics Engineering, kv Subba reddy engineering college for women.Email:[email protected]) ***( Assistant professor, Department of Electrical & Electronics Engineering, PVKK Institute of Technology . Email:v ...
STK984-090A-E 20A/40V Integrated Power Module in SIP23 package
STK984-090A-E 20A/40V Integrated Power Module in SIP23 package

... ON Semiconductor and the ON logo are registered trademarks of Semiconductor Components Industries, LLC (SCILLC) or its subsidiaries in the United States and/or other countries. SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A li ...
Improving the Active Power Filter Performance with a Prediction
Improving the Active Power Filter Performance with a Prediction

... widely studied and several methods to control them have been proposed, e.g. [1] – [4]. In harmonic filtering the active filter current reference generation plays an important role: if the reference is poor, a good filtering result cannot be achieved. A common problem in voltage source shunt active f ...
Evaluates: MAX1898 MAX1898 Evaluation Kit General Description Features
Evaluates: MAX1898 MAX1898 Evaluation Kit General Description Features

... The LED on the EV kit is driven by the CHG pin. Depending on the Li+ cell’s charging status, the pin is low or high impedance, thus turning the LED ON or OFF. If the Li+ cell cannot be charged to 2.5V in less than 1/4 of the total programmed charge time, the charger will go into fault mode. During t ...
A magnetically isolated gate driver for high
A magnetically isolated gate driver for high

Safety Induction to the Lift & Escalator Industry
Safety Induction to the Lift & Escalator Industry

... of surplus material,  Try to obtain suitable light levels (200 lux) at point of work,  Replace equipment covers on completion of work as soon as possible,  Use the wiring diagrams to understand the circuit you are working on; even though the main 3-phase isolator has been switched off, other sour ...
< 1 ... 371 372 373 374 375 376 377 378 379 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report