• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
6-Bit Voltage Output Multiplying DAC Datasheet MDAC6 V 2.2
6-Bit Voltage Output Multiplying DAC Datasheet MDAC6 V 2.2

... represented as numbers in 2’s complement or sign-and-magnitude form, ranging from -31 to +31. Alternatively, input codes may be represented in offset-binary form, as a number ranging from 0 to 62. This means that a one-step change in the output voltage represents one sixty-third of the full-scale ou ...
Power supplies and UPS
Power supplies and UPS

... 15 ms. Faulty current paths are switched off selectively, the fault is located, and important system parts remain in operation. Comprehensive diagnostics are provided through constant monitoring of the output voltage and output current. This preventive function monitoring visualizes critical operati ...
Wind Energy Systems for Electric Power - Van
Wind Energy Systems for Electric Power - Van

... significantly to wind energy conversion in the future. The theory of modern wind turbines has not been established before the 20th century. Currently wind turbines with three blades and horizontal shaft prevail. The driven electric generators are of the asynchronous or synchronous type, with or with ...
08. Operating Guide and Planning Guide Revisions
08. Operating Guide and Planning Guide Revisions

B  2.5 A Output Current, IGBT Drive Optocoupler with Desaturation Detection
B 2.5 A Output Current, IGBT Drive Optocoupler with Desaturation Detection

... substandard performance, failed applications, and increased cost of production and manufacturing delays. Fairchild is taking strong measures to protect ourselves and our customers from the proliferation of counterfeit parts. Fairchild strongly encourages customers to purchase Fairchild parts either ...
Mercedes Automatic Transmission Conductor Plate
Mercedes Automatic Transmission Conductor Plate

... better idea of how much fluid you will need to complete the job. Very few 722.6 applications are fitted with an ATF fluid level dipstick. The dipstick is available from febi – part number 38023. Remove the red locking tab on the transmission filler tube and remove the plug. The dipstick is around on ...
S320-42-1
S320-42-1

UltraCapacitors Presentation.doc
UltraCapacitors Presentation.doc

... electrons, from one metal plate and depositing them on another. This charge separation creates a potential between the two plates, which can be harnessed in an external circuit. The total energy stored in this fashion increases with both the amount of charge stored and the potential between the plat ...
HF2614291439
HF2614291439

... power system to develop restoring forces equal to or greater than the disturbing forces to maintain the state of equilibrium. Since power systems rely on synchronous machines for generation of electrical power, a necessary condition for satisfactory system operation is that all synchronous machines ...
LARGE TRANSFORMERS FOR POWER ELECTRONIC LOADS
LARGE TRANSFORMERS FOR POWER ELECTRONIC LOADS

... In transformers for twelve pulse loads, 5th and 7th harmonics flow in phase opposition in the LY and LD windings. Their magnetic leakage fields are essentially radial, and set up circulating currents between the parallel connected parts of both the primary winding and a possible filter winding. The ...
Texas Instruments Voltage-Level
Texas Instruments Voltage-Level

... configurations, which give the opportunity for designers to choose the optimal part for their applications. These devices have strict power-sequencing requirements that prevent excessive current flow or possible damage to the devices. These stringent requirements sometimes are difficult to meet from ...
Types of Electric Motors
Types of Electric Motors

industrial accelerometers
industrial accelerometers

...   05 bias voltage The DC operating voltage of the IEPE power circuit is often called the Bias voltage. Nominally this value is 12 VDC, but typically ranges from 10 – 14 VDC. Given that the IEPE circuit is a 2 wire design, both the sensor power and vibration signal must use these two wires to operate ...
Dial W eight Dial Weight Dynamometers
Dial W eight Dial Weight Dynamometers

... Remove any tape or packing material around the brake or weights. There should be as many weights, 2 or 3, as there are torque scales on the dynamometer dial including the (minimum scale) weight permanently attached to the brake assembly. The dynamometer ...
Aalborg Universitet
Aalborg Universitet

... controller and the communication system. Thus producing an appropriate control signal to be locally send to the local primary controller. In this sense, the failure of a DG unit will fail down only that individual unit and other DGs can work independent. Thus, adding more DG units is easy, making th ...
DuraNET 30-2020
DuraNET 30-2020

... mining, industrial), the unit provides reliable local area network (LAN) switching capabilities with the ease of use, secure access, and manageability expected from Cisco-based technology. Two levels of Cisco IOS software (LAN Lite or LAN Base) are available to support access layer connectivity and ...
CD35455460
CD35455460

... harmonic quality at the output as compared to a two level inverter. The Space Vector PWM of a three level inverter provides the additional advantage of superior harmonic quality. Increasing the number of voltage levels in the inverter without requiring higher ratings on individual devices can increa ...
STC03DE220HV
STC03DE220HV

... 27-Nov-2006 ...
International Electrical Engineering Journal (IEEJ) Vol. 7 (2016) No.3, pp. 2173-2181
International Electrical Engineering Journal (IEEJ) Vol. 7 (2016) No.3, pp. 2173-2181

... generator apparent power (0.4 pu considering the machine apparent power as a base power for the system). III. FUZZY LOGIC CONTROLLER DESIGN The fuzzy logic is dissimilar from the crispy logic in boolean theory which uses only two logic levels (0 or 1) in that it uses infinite logic levels (from 0 to ...
design, fabrication and simulations of
design, fabrication and simulations of

... A good alternative to batteries is miniature, selfcontained, renewable power supplies. These convert energy from an existing source in the environment into electrical energy. An example of this is the generation of electrical energy from kinetic energy using electromagnetic induction. Kinetic energy ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... reuse of their switching frequency. Consequently, the delivered trapezoidal voltage pulses reach considerably high values of dv/dt (often more than 10 kv/μs). Situated in a system consisting of the PWM inverter, feeding cable and induction motor (IM) is then strongly influenced by its leakage capaci ...
Overcoming Communications Challenges in Software for Monitoring and Controlling Power Systems
Overcoming Communications Challenges in Software for Monitoring and Controlling Power Systems

... trying to make sense of an evolving power shortage or some other slower contingency involves tracking data that evolves over periods measured in minutes. Still other forms of data change over hours or days. Our focus here is on the second case (minutes). Our group has also looked at problems on shor ...
Challenges of Dimming LED Loads on ELV and MLV
Challenges of Dimming LED Loads on ELV and MLV

... have previously been used. Dimmers are often used to enhance the user experience—switching to LEDs should not change this experience. Anyone who has used LED loads with low-voltage magnetic or electronic transformers in dimming applications has likely experienced confusion, frustration, and even dis ...
MAX4885AE Evaluation Kit Evaluates: General Description Features
MAX4885AE Evaluation Kit Evaluates: General Description Features

... connections are completed. 1) Verify that all jumpers (JU1–JU7) are in their default positions, as shown in Table 1. 2) Connect the monitor to VGA0 (VGA monitor). 3) Connect the first PC to VGA1 (VGA SRC1) and the second PC to VGA2 (VGA SRC2). 4) Turn on the power to both PCs and monitor. 5) Ve ...
BDTIC www.BDTIC.com/infineon W i r e l e s s  ... T D K 5 1 1 1
BDTIC www.BDTIC.com/infineon W i r e l e s s ... T D K 5 1 1 1

... All Rights Reserved. Attention please! As far as patents or other rights of third parties are concerned, liability is only assumed for components, not for applications, processes and circuits implemented within components or assemblies. The information describes the type of component and shall not b ...
< 1 ... 269 270 271 272 273 274 275 276 277 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report