LTC2970/LTC2970-1 - Dual I2C Power Supply Monitor and
... The LTC®2970 is a dual power supply monitor and margining controller with an SMBus compatible I2C bus interface. A low-drift, on-chip reference and 14-bit ΔΣ A/D converter allow precise measurements of supply voltages, load currents or internal die temperature. Fault management allows ALERT to be as ...
... The LTC®2970 is a dual power supply monitor and margining controller with an SMBus compatible I2C bus interface. A low-drift, on-chip reference and 14-bit ΔΣ A/D converter allow precise measurements of supply voltages, load currents or internal die temperature. Fault management allows ALERT to be as ...
MELSEC iQ-R I/O Module User's Manual
... [Design Precautions] CAUTION ● Do not install the control lines or communication cables together with the main circuit lines or power cables. Keep a distance of 100mm or more between them. Failure to do so may result in malfunction due to noise. ● During control of an inductive load such as a lamp, ...
... [Design Precautions] CAUTION ● Do not install the control lines or communication cables together with the main circuit lines or power cables. Keep a distance of 100mm or more between them. Failure to do so may result in malfunction due to noise. ● During control of an inductive load such as a lamp, ...
KX-TG4012LAT KX-TG4013LAT KX-TGA403LAT
... In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that contains lead. We will use PbF solder when discussing the lead free solder used in our manufacturing process which is made from Tin (Sn), Silver (Ag), and Copper (Cu). Th ...
... In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that contains lead. We will use PbF solder when discussing the lead free solder used in our manufacturing process which is made from Tin (Sn), Silver (Ag), and Copper (Cu). Th ...
MP28164 - Monolithic Power System
... cycle. SWA/SWB and SWC/SWD switch during this condition simultaneously. This is called buckboost mode. Boost Region (VIN < VOUT) When the input voltage is significantly lower than the output voltage, the control voltage (VC-Buck) is always higher than the current ramp signal. The offset voltage is a ...
... cycle. SWA/SWB and SWC/SWD switch during this condition simultaneously. This is called buckboost mode. Boost Region (VIN < VOUT) When the input voltage is significantly lower than the output voltage, the control voltage (VC-Buck) is always higher than the current ramp signal. The offset voltage is a ...
100327DRFSinLCWS.Beijin10
... the DC power supplies and MA modulators is associated with one backup units, which will be designed and implemented to be “hot-swappable”. • Each of the power and voltage distribution circuits will have a high-voltage SW or relay, which switches off the line when over current failures are detected. ...
... the DC power supplies and MA modulators is associated with one backup units, which will be designed and implemented to be “hot-swappable”. • Each of the power and voltage distribution circuits will have a high-voltage SW or relay, which switches off the line when over current failures are detected. ...
POWERDRIVE PHOENIX OPTIX POWER DISTRIBUTION CABLES Rapid deployment of critical power
... while te has made every reasonable effort to ensure the accuracy of the information herein, nothing While TE has made every reasonable effort to ensure the accuracy of the information herein, herein constitutes any guarantee that such nothing herein constitutes any guarantee that such information is ...
... while te has made every reasonable effort to ensure the accuracy of the information herein, nothing While TE has made every reasonable effort to ensure the accuracy of the information herein, herein constitutes any guarantee that such nothing herein constitutes any guarantee that such information is ...
Baluns: Choosing the Correct Balun
... Current baluns, especially 1:1 ratio baluns, tolerate load impedance and balance variations much better than voltage baluns. Current baluns can also be used as isolators or un-un's. Unless otherwise noted, DXE Baluns are current-type baluns. ...
... Current baluns, especially 1:1 ratio baluns, tolerate load impedance and balance variations much better than voltage baluns. Current baluns can also be used as isolators or un-un's. Unless otherwise noted, DXE Baluns are current-type baluns. ...
Dynamic Gate
... Only a single 0 1 transition allowed at the inputs during the evaluation period! Out2 should remain at VDD since Out1 transitions to 0 during evaluation a finite propagation delay for the input to discharge Out1 to GND, the second output also starts to discharge. This loss will not be recovered an ...
... Only a single 0 1 transition allowed at the inputs during the evaluation period! Out2 should remain at VDD since Out1 transitions to 0 during evaluation a finite propagation delay for the input to discharge Out1 to GND, the second output also starts to discharge. This loss will not be recovered an ...
Liebert® NXL™ UPS
... continuously powered by a method that provides higher efficiency than that provided with normal operation. Battery float charging shall be the same as during Normal operation. C. Emergency: Upon failure of utility AC power, the critical AC load shall be powered by the inverter which, without any swi ...
... continuously powered by a method that provides higher efficiency than that provided with normal operation. Battery float charging shall be the same as during Normal operation. C. Emergency: Upon failure of utility AC power, the critical AC load shall be powered by the inverter which, without any swi ...
AN84 - Linear Technology Magazine Circuit Collection, Volume IV
... timer is accomplished by counting 216 oscillator cycles, yielding a delay-to-release reset of approximately 300ms in a typical application. The EXT VCC pin is normally connected to the 5V output to allow INT VCC power to be derived from the regulator itself. Quiescent current is then reduced because ...
... timer is accomplished by counting 216 oscillator cycles, yielding a delay-to-release reset of approximately 300ms in a typical application. The EXT VCC pin is normally connected to the 5V output to allow INT VCC power to be derived from the regulator itself. Quiescent current is then reduced because ...
BDTIC www.BDTIC.com/infineon Infineon Solar Power Solutions www.infineon.com
... Up to 4x 12-bit ADC achieving 4 Mega samples per second (interleaved mode) DAVE3™ – Free Development Platform ...
... Up to 4x 12-bit ADC achieving 4 Mega samples per second (interleaved mode) DAVE3™ – Free Development Platform ...
UNIT 16 ELECTRIC MOTORS
... an auger to meter high-protein supplement into a cattle feeding system. Although the motor requires direct current, the supply is usually alternating current. A solidstate rectifier in the motor controller changes ac to de. One type of direct-current motor can also operate on alternating current. Th ...
... an auger to meter high-protein supplement into a cattle feeding system. Although the motor requires direct current, the supply is usually alternating current. A solidstate rectifier in the motor controller changes ac to de. One type of direct-current motor can also operate on alternating current. Th ...
PQMII Power Quality Meter Instruction Manual
... GE Digital Energy PQMII Power Quality Meter instruction manual for revision 2.2x. PQMII Power Quality Meter, is a registered trademark of GE Digital Energy Inc. The contents of this manual are the property of GE Digital Energy Inc. This documentation is furnished on license and may not be reproduced ...
... GE Digital Energy PQMII Power Quality Meter instruction manual for revision 2.2x. PQMII Power Quality Meter, is a registered trademark of GE Digital Energy Inc. The contents of this manual are the property of GE Digital Energy Inc. This documentation is furnished on license and may not be reproduced ...
What are Circuit Breakers?
... All circuit breakers have common features in their operation, although details vary substantially depending on the voltage class, current rating and type of the circuit breaker. The circuit breaker must detect a fault condition; in low-voltage circuit breakers this is usually done within the breaker ...
... All circuit breakers have common features in their operation, although details vary substantially depending on the voltage class, current rating and type of the circuit breaker. The circuit breaker must detect a fault condition; in low-voltage circuit breakers this is usually done within the breaker ...
16 Transformer and Transformer-feeder Protection
... A number of factors affect the magnitude and duration of the magnetising current inrush: a. residual flux – worst-case conditions result in the flux peak value attaining 280% of normal value b. point on wave switching c. number of banked transformers d. transformer design and rating e. system fault ...
... A number of factors affect the magnitude and duration of the magnetising current inrush: a. residual flux – worst-case conditions result in the flux peak value attaining 280% of normal value b. point on wave switching c. number of banked transformers d. transformer design and rating e. system fault ...
Liebert Distribution Monitoring (LDM)
... The Liebert LDM consists of a control board, panelboard voltage and current board, power supply boards and sensor modules and can monitor two 42-pole panelboards and three subfeed breakers. The Liebert LDM is capable of receiving input from 21-pole current sensor modules; two sensor modules are requ ...
... The Liebert LDM consists of a control board, panelboard voltage and current board, power supply boards and sensor modules and can monitor two 42-pole panelboards and three subfeed breakers. The Liebert LDM is capable of receiving input from 21-pole current sensor modules; two sensor modules are requ ...
Design and Analysis of a Novel Multilevel Active-Clamped Power-Converter T
... power conversion system. However, a larger quantity of semiconductors is needed and the modulation strategy to control them becomes more complex. There are three basic multilevel converter topologies: diode clamped, flying capacitor, and cascaded H-bridge with separate dc sources. Numerous hybrid co ...
... power conversion system. However, a larger quantity of semiconductors is needed and the modulation strategy to control them becomes more complex. There are three basic multilevel converter topologies: diode clamped, flying capacitor, and cascaded H-bridge with separate dc sources. Numerous hybrid co ...
Breakers, Relays, and Disconnects
... These are the most common relay protection devices in use. Different levels of overcurrent protection are frequently included in power systems to provide the necessary protection without causing unnecessary system interruptions. Instantaneous Overcurrent An instantaneous overcurrent relay (also know ...
... These are the most common relay protection devices in use. Different levels of overcurrent protection are frequently included in power systems to provide the necessary protection without causing unnecessary system interruptions. Instantaneous Overcurrent An instantaneous overcurrent relay (also know ...
Mini-Gel Electrophoresis Unit for DNA, RNA and Protein
... 2. Place the gel maker plate on the gel maker stand. Good results have been obtained by covering the iside of the gel maker plate with a gel bonding sheet. Cut the sheet to the specified size (106 58 mm for a large gel, 51 58 mm for a small gel). These sheets protect the polyacrylamide gel and facil ...
... 2. Place the gel maker plate on the gel maker stand. Good results have been obtained by covering the iside of the gel maker plate with a gel bonding sheet. Cut the sheet to the specified size (106 58 mm for a large gel, 51 58 mm for a small gel). These sheets protect the polyacrylamide gel and facil ...
Virtex-5 FPGA PCB Designer’s Guide www.BDTIC.com/XILINX UG203 (v1.4) April 20, 2009
... A via is a piece of metal making an electrical connection between two or more points in the Z space of a PCB. Vias carry signals or power between layers of a PCB. In current platedthrough-hole (PTH) technology, a via is formed by plating the inner surface of a hole drilled through the PCB. In curren ...
... A via is a piece of metal making an electrical connection between two or more points in the Z space of a PCB. Vias carry signals or power between layers of a PCB. In current platedthrough-hole (PTH) technology, a via is formed by plating the inner surface of a hole drilled through the PCB. In curren ...
Power engineering
Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.