 
									
								
									Lumenition Ignition System Description
									
... Identification of a Performance Ignition System. The Performance Ignition system has a black powder-coated alloy external power module (see figure). Product code CEM The connector used in the Performance Ignition system is a 3 pin euro-connector with an O-ring seal and grommet wire-entry seals which ...
                        	... Identification of a Performance Ignition System. The Performance Ignition system has a black powder-coated alloy external power module (see figure). Product code CEM The connector used in the Performance Ignition system is a 3 pin euro-connector with an O-ring seal and grommet wire-entry seals which ...
									a CMOS Low Voltage 4 ADG704
									
... The ADG704 offers high performance and is fully specified and guaranteed with +3 V and +5 V supply rails. ...
                        	... The ADG704 offers high performance and is fully specified and guaranteed with +3 V and +5 V supply rails. ...
									Alberta Reliability Standard Cyber Security – BES Cyber System Categorization CIP-002-AB-5.1
									
... commissioned generation, by each group of generating units or aggregated generating facilities at a single plant location, with an aggregate highest rated net maximum authorized real power capabilityrating of each of the preceding 12 monthsgenerating units minus the station service load equal to or ...
                        	... commissioned generation, by each group of generating units or aggregated generating facilities at a single plant location, with an aggregate highest rated net maximum authorized real power capabilityrating of each of the preceding 12 monthsgenerating units minus the station service load equal to or ...
									Automotive TVS Diodes Application Note
									
... Table 1a summarizes the compliance of each level of the ISO7637-2 surge test in 12V and 24V power systems when using various Littelfuse Automotive TVS Diode series. Series TPSMA6L, TPSMB, TP6KE, TPSMC and TPSMD feature pulse power ratings of 600W, 600W, 600W, 1500W and 3000W respectively. TP6KE seri ...
                        	... Table 1a summarizes the compliance of each level of the ISO7637-2 surge test in 12V and 24V power systems when using various Littelfuse Automotive TVS Diode series. Series TPSMA6L, TPSMB, TP6KE, TPSMC and TPSMD feature pulse power ratings of 600W, 600W, 600W, 1500W and 3000W respectively. TP6KE seri ...
									Starter  - Linn-Benton Community College Homepage
									
... High Cranking Amps Check voltage drop across STARTER MOTOR If Battery cranking volt is 1/2 volt more than Starter volt drop diagnose battery cables and connections ...
                        	... High Cranking Amps Check voltage drop across STARTER MOTOR If Battery cranking volt is 1/2 volt more than Starter volt drop diagnose battery cables and connections ...
									Companion Service Guide
									
... • Make sure that the electrical connections are secure. Unplug the connectors and make sure all of the pins are seated properly. Push the pins back into the connector housing if necessary. Make sure that the battery terminals are tight. NOTE: If you get to a point during troubleshooting where you ca ...
                        	... • Make sure that the electrical connections are secure. Unplug the connectors and make sure all of the pins are seated properly. Push the pins back into the connector housing if necessary. Make sure that the battery terminals are tight. NOTE: If you get to a point during troubleshooting where you ca ...
									Sevcon Powerpak trouble shooting guide
									
... The PowerpaK range of Controllers uses a new concept in power switching technology to provide a full range of power frames 24V-80V, 300A-650A in one small, highly efficient package. This is achieved using a new power switching scheme and radical new construction techniques, both the subject of paten ...
                        	... The PowerpaK range of Controllers uses a new concept in power switching technology to provide a full range of power frames 24V-80V, 300A-650A in one small, highly efficient package. This is achieved using a new power switching scheme and radical new construction techniques, both the subject of paten ...
									(20-100 Amps).
									
... 3.5. C.C. Shorting: Meter shall record C.C. Terminal shorting with time and date and time of restoration. The threshold of the current should be programmable. 3.6. Power On / Off: Meter shall detect power OFF (minimum power off period 5 minutes) if any of phase voltages are not present. This event s ...
                        	... 3.5. C.C. Shorting: Meter shall record C.C. Terminal shorting with time and date and time of restoration. The threshold of the current should be programmable. 3.6. Power On / Off: Meter shall detect power OFF (minimum power off period 5 minutes) if any of phase voltages are not present. This event s ...
									Adam Equipment ADK PRECISION BALANCES
									
... zero value setting will result in the display showing a “-P “ indication whereas a too big one will result in a “+E “ indication at full capacity. To set the zero value: Turn the main power off. Press the [Tare] key, turn on main power on. The model of balance - C20000.0 will be displayed for one or ...
                        	... zero value setting will result in the display showing a “-P “ indication whereas a too big one will result in a “+E “ indication at full capacity. To set the zero value: Turn the main power off. Press the [Tare] key, turn on main power on. The model of balance - C20000.0 will be displayed for one or ...
									Electronics – A First Course 2nd edition Owen Bishop
									
... The source terminal is common to both the input and output sides of this MOSFET amplifier, so it is known as a common-source amplifier (p. 63) Electronics – Circuits and Systems 3rd edition. © 2007, Owen Bishop. Published by Elsevier Ltd. ...
                        	... The source terminal is common to both the input and output sides of this MOSFET amplifier, so it is known as a common-source amplifier (p. 63) Electronics – Circuits and Systems 3rd edition. © 2007, Owen Bishop. Published by Elsevier Ltd. ...
									SEL-351 Distribution and Transmission Relay Standard Features
									
... Programmable four-shot recloser with synchronism check matches your reclosing practice. Phase and sequence under- and overvoltage elements increase control scheme flexibility. Six steps of accurate frequency elements for multilevel under- and overfrequency trip and control. Event Reports and Sequent ...
                        	... Programmable four-shot recloser with synchronism check matches your reclosing practice. Phase and sequence under- and overvoltage elements increase control scheme flexibility. Six steps of accurate frequency elements for multilevel under- and overfrequency trip and control. Event Reports and Sequent ...
									D-TEK Vehicle Loop Detector Instructions
									
... 7. Pulse Detect/Un-detect- this feature is controlled by DIP switch 2 on the back of the detector. Allows for activation on entering into the loop or exiting from the loop. 8. Constant Presence / 4 minute limit- this feature is controlled by DIP switch 3 on the back of the detector and allows for th ...
                        	... 7. Pulse Detect/Un-detect- this feature is controlled by DIP switch 2 on the back of the detector. Allows for activation on entering into the loop or exiting from the loop. 8. Constant Presence / 4 minute limit- this feature is controlled by DIP switch 3 on the back of the detector and allows for th ...
									AAT4616A 数据资料DataSheet下载
									
... saturated region of operation by being automatically shutting down via an under-voltage lockout circuit. Current limit or over temperature conditions are reported by the open drain FAULT output. A 4ms blanking interval prevents false reporting during the charging of a capacitive load, which typicall ...
                        	... saturated region of operation by being automatically shutting down via an under-voltage lockout circuit. Current limit or over temperature conditions are reported by the open drain FAULT output. A 4ms blanking interval prevents false reporting during the charging of a capacitive load, which typicall ...
									Technical Requirements for Subsea High Voltage Direct
									
... specific system with detailed design • Focus on transmission side – more challenging for connectors than distribution side (distribution voltage is lower, and system protection will be coordinated to meet current ratings for connectors) ...
                        	... specific system with detailed design • Focus on transmission side – more challenging for connectors than distribution side (distribution voltage is lower, and system protection will be coordinated to meet current ratings for connectors) ...
									Electrical Class Handout (Primary)
									
... Section 525-16 states that overcurrent protection of equipment and conductors shall be provided in accordance with Article 240. Tents and concession stands that are fed by circuit to which cords or cables are connected must have overcurrent protection that protects the cord or cable as well as equi ...
                        	... Section 525-16 states that overcurrent protection of equipment and conductors shall be provided in accordance with Article 240. Tents and concession stands that are fed by circuit to which cords or cables are connected must have overcurrent protection that protects the cord or cable as well as equi ...
									Datasheet - Diodes Incorporated
									
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
                        	... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
									T3V3S5 / T5V0S5 / T6V0S5 / T12S5
									
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
                        	... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
									Slide - Indico
									
... – Beam dump interlock from Pload and Vcav (also He pressure for quenches), not from a trip. ...
                        	... – Beam dump interlock from Pload and Vcav (also He pressure for quenches), not from a trip. ...
									ERMCO Components
									
... Limiting back up fuse. In this latter case, secondary faults and overload currents are cleared by the Bay-O-Net Fuse, and high-level faults are cleared by the Current Limiting Fuse. The two fuses are connected in series, and coordinated so that the Current Limiting Fuse operates only upon internal e ...
                        	... Limiting back up fuse. In this latter case, secondary faults and overload currents are cleared by the Bay-O-Net Fuse, and high-level faults are cleared by the Current Limiting Fuse. The two fuses are connected in series, and coordinated so that the Current Limiting Fuse operates only upon internal e ...
									Reliable Protection for systems, generators and motors up to 1600 A
									
... The North American user guidelines prescribe that the actuating device must be permanently connected to the switch. This also applies when the control panel door is open. The new door coupling handle developed by Eaton, with additional handle on the switch, complies with this requirement. The new ha ...
                        	... The North American user guidelines prescribe that the actuating device must be permanently connected to the switch. This also applies when the control panel door is open. The new door coupling handle developed by Eaton, with additional handle on the switch, complies with this requirement. The new ha ...
									Controls_Thoughts-04-04-2015-for_MIPO
									
... interfaces. It’s contents are subject to substantial change and update. Structure Page 1 and 2 define key areas where I perceive monitoring and possibly interlocking is required. At present this may require further subdivision into individual inputs. Subsequent pages use these subsystems to define t ...
                        	... interfaces. It’s contents are subject to substantial change and update. Structure Page 1 and 2 define key areas where I perceive monitoring and possibly interlocking is required. At present this may require further subdivision into individual inputs. Subsequent pages use these subsystems to define t ...
									here
									
... However, unlike the technique used for testing transmission lines, the rotor winding is a very imperfect transmission line and produces a large number of reflections at each change in impedance between the sections of conductors inside the radial slots and the sections in the cross-over end regions. ...
                        	... However, unlike the technique used for testing transmission lines, the rotor winding is a very imperfect transmission line and produces a large number of reflections at each change in impedance between the sections of conductors inside the radial slots and the sections in the cross-over end regions. ...
									Switch-on-to-Fault Schemes in the Context of Line Relay
									
... lower, and where the need to restore the transmission path was critical. The goal, therefore, is that SOTF schemes should not operate falsely for any condition where breaker closing is called for either by decision of the system operator or by an automatic reclosing scheme. ...
                        	... lower, and where the need to restore the transmission path was critical. The goal, therefore, is that SOTF schemes should not operate falsely for any condition where breaker closing is called for either by decision of the system operator or by an automatic reclosing scheme. ...
Fault tolerance
 
                        Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.
 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									