speech scrambler
... Communicate in privacy over any audio path! Full duplex operation so this unit can scramble and descramble at the same time! E-Z hookup instructions for radio, or scanner. ...
... Communicate in privacy over any audio path! Full duplex operation so this unit can scramble and descramble at the same time! E-Z hookup instructions for radio, or scanner. ...
CA165005EN/ Old 165-265
... the relay. Many of these event views are also available in On-Line View mode, where it is possible to monitor the status of the relay in real-time, including phasor diagrams, which is ideal for verifying CT phasing during commissioning. ...
... the relay. Many of these event views are also available in On-Line View mode, where it is possible to monitor the status of the relay in real-time, including phasor diagrams, which is ideal for verifying CT phasing during commissioning. ...
DC200B Chapter 7 - Del Mar College
... Telecommunications Closet—must be dedicated to telecommunications functions and support facilities only, with a minimum of one closet per floor. Additional closets should be provided for each area up to 10,000 square feet (1,000 square meters) when either the floor area served exceeds 10,000 square ...
... Telecommunications Closet—must be dedicated to telecommunications functions and support facilities only, with a minimum of one closet per floor. Additional closets should be provided for each area up to 10,000 square feet (1,000 square meters) when either the floor area served exceeds 10,000 square ...
... off-site ac power for the LNP 1 and LNP 2 via a common switchyard. The connections of LNP 1, LNP 2, the switchyard, and the 500 kV transmission system are shown in Figures 8.2-201 and 8.2-202 respectively. The common 500 kV/230 kV switchyard provides a 500 kV circuit feed to the main step-up transfo ...
Extending Power Cable Life an Additional 40 Years
... cable runs of up to 750 meters are common. The cable paths are not straight. Cable might be in conduit, or interlaced with other cables in one or more cable trays on different levels. The cable trays might not be accessible. The conduit may have collapsed, preventing the cable from being easily pull ...
... cable runs of up to 750 meters are common. The cable paths are not straight. Cable might be in conduit, or interlaced with other cables in one or more cable trays on different levels. The cable trays might not be accessible. The conduit may have collapsed, preventing the cable from being easily pull ...
DRAFT REGULATORY GUIDE DG-1172 DRAFT REGULATORY GUIDE
... an improperly adjusted control system or governor failure, is provided by the immediate operation of a diesel generator trip, which is usually set at 115 percent of nominal speed. Similarly, to prevent substantial damage to the generator, the generator differential current trip must operate immediat ...
... an improperly adjusted control system or governor failure, is provided by the immediate operation of a diesel generator trip, which is usually set at 115 percent of nominal speed. Similarly, to prevent substantial damage to the generator, the generator differential current trip must operate immediat ...
SWITCHGEAR
... Finish: Steel parts shall be prepared for painting by a five-stage wash system consisting of an alkaline cleaner, fresh water rise, iron phosphate treatment, fresh water rise and non-chromate sealer. After cleaning and stabilization, the steel parts shall be coated with a thermosetting polyester pow ...
... Finish: Steel parts shall be prepared for painting by a five-stage wash system consisting of an alkaline cleaner, fresh water rise, iron phosphate treatment, fresh water rise and non-chromate sealer. After cleaning and stabilization, the steel parts shall be coated with a thermosetting polyester pow ...
ITE-5HK250-MAG-VAC, 1200A, 2000A Medium
... the circuit breaker so that no damage will occur from careless or rough handling or from exposure to moisture or dirt. Save the shipping material for storing the circuit breaker when not in use. Verify the order with the packing list to ensure that no components have been overlooked or misplaced, su ...
... the circuit breaker so that no damage will occur from careless or rough handling or from exposure to moisture or dirt. Save the shipping material for storing the circuit breaker when not in use. Verify the order with the packing list to ensure that no components have been overlooked or misplaced, su ...
Block D: Semiconductor Electronics
... Silicon is the dominant semiconductor material used in the electronics industry. In a cubic meter of silicon, there are roughly 1028 atoms. Among these 1028, there will be about 1.5×1016 vacancies at room temperature. This is known as the intrinsic carrier concentration: n = 1.5×1016 electrons/m3. T ...
... Silicon is the dominant semiconductor material used in the electronics industry. In a cubic meter of silicon, there are roughly 1028 atoms. Among these 1028, there will be about 1.5×1016 vacancies at room temperature. This is known as the intrinsic carrier concentration: n = 1.5×1016 electrons/m3. T ...
Industrial Current/Voltage Output Driver with Programmable Ranges AD5748
... The flexible serial interface is SPI- and MICROWIRE-compatible and can be operated in 3-wire mode to minimize the digital isolation required in isolated applications. The interface also features an optional PEC error checking feature using CRC-8 error checking, useful in industrial environments wher ...
... The flexible serial interface is SPI- and MICROWIRE-compatible and can be operated in 3-wire mode to minimize the digital isolation required in isolated applications. The interface also features an optional PEC error checking feature using CRC-8 error checking, useful in industrial environments wher ...
22B-QS001G-EN-P PowerFlex 40 Adjustable Frequency AC Drive
... intended for qualified drive service personnel only. For detailed PowerFlex 40 information including EMC instructions, application considerations and related precautions, refer to the PowerFlex 40 User Manual, Publication 22B-UM001… at www.rockwellautomation.com/literature. ...
... intended for qualified drive service personnel only. For detailed PowerFlex 40 information including EMC instructions, application considerations and related precautions, refer to the PowerFlex 40 User Manual, Publication 22B-UM001… at www.rockwellautomation.com/literature. ...
Sigma-7 Series AC Servo Drive - Yaskawa
... • Whenever possible, use the Cables specified by Yaskawa. If you use any other cables, confirm the rated current and application environment of your model and use the wiring materials specified by Yaskawa or equivalent materials. • Securely tighten cable connector screws and lock mechanisms. Insuffi ...
... • Whenever possible, use the Cables specified by Yaskawa. If you use any other cables, confirm the rated current and application environment of your model and use the wiring materials specified by Yaskawa or equivalent materials. • Securely tighten cable connector screws and lock mechanisms. Insuffi ...
Cable Fault Location - HV TECHNOLOGIES, Inc.
... Power supply networks are growing continuously and their reliability is getting more important than ever. The complexity of the whole network comprises numerous components that can fail and interrupt the power supply for the end user. For most of the worldwide operated low voltage and medium voltage ...
... Power supply networks are growing continuously and their reliability is getting more important than ever. The complexity of the whole network comprises numerous components that can fail and interrupt the power supply for the end user. For most of the worldwide operated low voltage and medium voltage ...
Power system protection
... APPLICATION Protection Zones Observation PROTECTIO ZONES PROTECTION ZONES EXAMPLE, ...
... APPLICATION Protection Zones Observation PROTECTIO ZONES PROTECTION ZONES EXAMPLE, ...
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
... multipliers have high delay then the overall performance of the device will be reduced. Moreover, there are some temperature instability effects such as NBTI (Negative bias temperature instability) and PBTI (Positive bias temperature instability) occurs at the harsh environment in some applications ...
... multipliers have high delay then the overall performance of the device will be reduced. Moreover, there are some temperature instability effects such as NBTI (Negative bias temperature instability) and PBTI (Positive bias temperature instability) occurs at the harsh environment in some applications ...
CE4301462465
... different applications such as Digital signal processor, microcontroller, microprocessor and data processing units. Due to scaling trends and portability of electronic devices there is a high demand and need for low power and high speed digital circuits with small silicon area. So, design and analys ...
... different applications such as Digital signal processor, microcontroller, microprocessor and data processing units. Due to scaling trends and portability of electronic devices there is a high demand and need for low power and high speed digital circuits with small silicon area. So, design and analys ...
Folha de dados do detector de duto para ar
... RZA 142 and display them visually. In addition to the visual display a potential-free changeover switch is available for each state and can be used to activate or forward the states to higher-level systems such as a building services management system. Convenience As the smoke switches are easy to m ...
... RZA 142 and display them visually. In addition to the visual display a potential-free changeover switch is available for each state and can be used to activate or forward the states to higher-level systems such as a building services management system. Convenience As the smoke switches are easy to m ...
Fault tolerance
Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.